이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Safety of External Electrocardioversion in Device Patients (SEED)

2017년 11월 3일 업데이트: Universitätsklinikum Köln

Safety of External Electrocardioversion in Device Patients - the SEED Registry

Arrhythmias of the atria of the heart are a common comorbidity in patients with cardiac rhythm management devices, such as pacemakers and implantable cardioverter/defibrillators (ICD). External electrical cardioversion is an established method to achieve rhythm control (restore normal sinus rhythm) in patients with atrial arrhythmia. Little data on safety and efficacy of external electrical cardioversion in patients with cardiac rhythm management devices exists. Thus, available data on the safety of external electrical cardioversion in cardiac rhythm management patients lacks statistical power to accurately reflect the true hazard of external electrical cardioversion in patients with cardiac rhythm management devices.

The aim is to systematically include and follow all patients with cardiac rhythm management devices presenting for external electrical cardioversion, to analyse the effects of external electrical cardioversion on leads and devices.

연구 개요

상태

알려지지 않은

개입 / 치료

상세 설명

Introduction Atrial arrhythmias are a common comorbidity in patients with cardiac rhythm management (CRM) devices, such as pacemakers and ICD. External electrical cardioversion is an established method to achieve rhythm control in patients with atrial arrhythmia. A paucity of data on safety and efficacy of external electrical cardioversion in patients with cardiac rhythm management devices exists. Most publications are of older date and predominantly case reports or case collections. Few prospective studies with a population of cardiac rhythm management patients after external electrical cardioversion have been published in recent years.

Thus, available data on the safety of external electrical cardioversion in cardiac rhythm management patients lacks statistical power to accurately reflect the true hazard of external electrical cardioversion in patients with cardiac rhythm management devices.

Rationale Electrocardioversion in Propofol sedation for atrial or ventricular tachyarrhythmia is an established therapy. It is routinely used for patients with cardiac rhythm management devices and the risk of device and lead affectation is deemed to be low. This assumption is currently not supported by substantial and current scientific data, mostly relying on older reports. No large, prospective trials with a population of patients with modern cardiac rhythm management devices exists.

Aim of the study The aim is to systematically include and follow all patients with cardiac rhythm management devices presenting for external electrical cardioversion, to analyse the effects of external electrical cardioversion on leads and devices. Thereby, providing reliable evidence and detecting possible SAE with a low incidence. Furthermore, to gather information on efficacy and recurrence rate in this population, to examine the value of external electrical cardioversion for rhythm control in these patients.

연구 유형

관찰

등록 (예상)

300

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

      • Cologne, 독일, 50937
        • 모병
        • University Hospital Cologne
        • 연락하다:
        • 수석 연구원:
          • Jakob Lüker, Dr.

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

샘플링 방법

확률 샘플

연구 인구

All patients with implanted cardiac rhythm devices (pacemakers, ICD and CRT)

설명

Inclusion Criteria:

  • Age ≥ 18 years
  • Informed, written consent
  • Atrial or ventricular arrhythmia with indication for CV
  • Status post CRM implantation, including CRT-D

Exclusion Criteria:

  • Age < 18 years
  • Patients under guardianship or with mental disorders / disabilities
  • lead implantation < 4 weeks prior to CV
  • contraindications for eCV or transoesophageal echocardiographie (TOE)

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 관찰 모델: 보병대
  • 시간 관점: 유망한

코호트 및 개입

그룹/코호트
개입 / 치료
Pacemaker patients
Patients with pacemaker, presenting for cardioversion.
ICD patients
Patients with ICD, presenting for cardioversion.
CRT patients
Patients with CRT device, presenting for cardioversion.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Composite safety endpoint: Changes of lead and device parameters
기간: 2 weeks after CV

assessed by device interrogation, if any of the following criteria is met:

  • a rise in threshold (at constant pulse duration) of >1V
  • exit block of any of the pacing leads
  • loss of programming of the device
  • rise in shock impedance by 50%
  • rise in charge time by 50%
  • drop in battery voltage of ≥0.2V within < 6 weeks
2 weeks after CV

2차 결과 측정

결과 측정
측정값 설명
기간
Efficacy Endpoint
기간: within 15 minutes after CV

Assessed by device interrogation and 12-lead ECG:

- restoration of normal sinus rhythm after CV

within 15 minutes after CV
Late changes of lead parameters
기간: 2 weeks after CV

Any of the below, assessed by device interrogation:

  • Lead impedance > 1000 Ohm
  • a rise in lead impedance by 50%
  • ventricular lead sensing < 2mV
  • atrial lead sensing < 1mV
2 weeks after CV
Inadvertent induction of ventricular fibrillation
기간: 10 seconds after CV
Assessed by 3 lead monitoring ECG
10 seconds after CV
Composite endpoint: Early lead changes
기간: within 15 minutes after CV

assessed by device interrogation, if any of the following criteria is met:

  • a rise in threshold (at constant pulse duration) of >1V
  • exit block of any of the pacing leads
  • Lead impedance > 1000 Ohm
  • a rise in lead impedance by 50%
  • ventricular lead sensing < 2mV
  • atrial lead sensing < 1mV
within 15 minutes after CV
Loss of programming
기간: within 15 minutes after CV

assessed by device interrogation:

- loss of programming of the device

within 15 minutes after CV
Change of shock impedance
기간: within 15 minutes after CV

assessed by device interrogation:

- rise in shock impedance by 50%

within 15 minutes after CV
Change of charge time
기간: within 15 minutes after CV

assessed by device interrogation:

- rise in charge time by 50%

within 15 minutes after CV

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 수석 연구원: Jakob Lüker, Dr., University Hospital Cologne
  • 연구 책임자: Daniel Steven, Prof. Dr., University Hospital Cologne

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작

2014년 9월 1일

기본 완료 (예상)

2018년 11월 1일

연구 완료 (예상)

2018년 12월 1일

연구 등록 날짜

최초 제출

2014년 9월 5일

QC 기준을 충족하는 최초 제출

2014년 9월 16일

처음 게시됨 (추정)

2014년 9월 19일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2017년 11월 6일

QC 기준을 충족하는 마지막 업데이트 제출

2017년 11월 3일

마지막으로 확인됨

2017년 11월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • UKK-SEED-2014

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .