Safety of External Electrocardioversion in Device Patients (SEED)
Safety of External Electrocardioversion in Device Patients - the SEED Registry
Arrhythmias of the atria of the heart are a common comorbidity in patients with cardiac rhythm management devices, such as pacemakers and implantable cardioverter/defibrillators (ICD). External electrical cardioversion is an established method to achieve rhythm control (restore normal sinus rhythm) in patients with atrial arrhythmia. Little data on safety and efficacy of external electrical cardioversion in patients with cardiac rhythm management devices exists. Thus, available data on the safety of external electrical cardioversion in cardiac rhythm management patients lacks statistical power to accurately reflect the true hazard of external electrical cardioversion in patients with cardiac rhythm management devices.
The aim is to systematically include and follow all patients with cardiac rhythm management devices presenting for external electrical cardioversion, to analyse the effects of external electrical cardioversion on leads and devices.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Introduction Atrial arrhythmias are a common comorbidity in patients with cardiac rhythm management (CRM) devices, such as pacemakers and ICD. External electrical cardioversion is an established method to achieve rhythm control in patients with atrial arrhythmia. A paucity of data on safety and efficacy of external electrical cardioversion in patients with cardiac rhythm management devices exists. Most publications are of older date and predominantly case reports or case collections. Few prospective studies with a population of cardiac rhythm management patients after external electrical cardioversion have been published in recent years.
Thus, available data on the safety of external electrical cardioversion in cardiac rhythm management patients lacks statistical power to accurately reflect the true hazard of external electrical cardioversion in patients with cardiac rhythm management devices.
Rationale Electrocardioversion in Propofol sedation for atrial or ventricular tachyarrhythmia is an established therapy. It is routinely used for patients with cardiac rhythm management devices and the risk of device and lead affectation is deemed to be low. This assumption is currently not supported by substantial and current scientific data, mostly relying on older reports. No large, prospective trials with a population of patients with modern cardiac rhythm management devices exists.
Aim of the study The aim is to systematically include and follow all patients with cardiac rhythm management devices presenting for external electrical cardioversion, to analyse the effects of external electrical cardioversion on leads and devices. Thereby, providing reliable evidence and detecting possible SAE with a low incidence. Furthermore, to gather information on efficacy and recurrence rate in this population, to examine the value of external electrical cardioversion for rhythm control in these patients.
Tipo de estudio
Inscripción (Anticipado)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Cologne, Alemania, 50937
- Reclutamiento
- University Hospital Cologne
-
Contacto:
- Daniel Steven, Prof. Dr.
- Número de teléfono: 32396 +49221478
- Correo electrónico: daniel.steven@uk-koeln.de
-
Investigador principal:
- Jakob Lüker, Dr.
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
- Age ≥ 18 years
- Informed, written consent
- Atrial or ventricular arrhythmia with indication for CV
- Status post CRM implantation, including CRT-D
Exclusion Criteria:
- Age < 18 years
- Patients under guardianship or with mental disorders / disabilities
- lead implantation < 4 weeks prior to CV
- contraindications for eCV or transoesophageal echocardiographie (TOE)
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Modelos observacionales: Grupo
- Perspectivas temporales: Futuro
Cohortes e Intervenciones
Grupo / Cohorte |
Intervención / Tratamiento |
|---|---|
|
Pacemaker patients
Patients with pacemaker, presenting for cardioversion.
|
|
|
ICD patients
Patients with ICD, presenting for cardioversion.
|
|
|
CRT patients
Patients with CRT device, presenting for cardioversion.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Composite safety endpoint: Changes of lead and device parameters
Periodo de tiempo: 2 weeks after CV
|
assessed by device interrogation, if any of the following criteria is met:
|
2 weeks after CV
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Efficacy Endpoint
Periodo de tiempo: within 15 minutes after CV
|
Assessed by device interrogation and 12-lead ECG: - restoration of normal sinus rhythm after CV |
within 15 minutes after CV
|
|
Late changes of lead parameters
Periodo de tiempo: 2 weeks after CV
|
Any of the below, assessed by device interrogation:
|
2 weeks after CV
|
|
Inadvertent induction of ventricular fibrillation
Periodo de tiempo: 10 seconds after CV
|
Assessed by 3 lead monitoring ECG
|
10 seconds after CV
|
|
Composite endpoint: Early lead changes
Periodo de tiempo: within 15 minutes after CV
|
assessed by device interrogation, if any of the following criteria is met:
|
within 15 minutes after CV
|
|
Loss of programming
Periodo de tiempo: within 15 minutes after CV
|
assessed by device interrogation: - loss of programming of the device |
within 15 minutes after CV
|
|
Change of shock impedance
Periodo de tiempo: within 15 minutes after CV
|
assessed by device interrogation: - rise in shock impedance by 50% |
within 15 minutes after CV
|
|
Change of charge time
Periodo de tiempo: within 15 minutes after CV
|
assessed by device interrogation: - rise in charge time by 50% |
within 15 minutes after CV
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Jakob Lüker, Dr., University Hospital Cologne
- Director de estudio: Daniel Steven, Prof. Dr., University Hospital Cologne
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Anticipado)
Finalización del estudio (Anticipado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- UKK-SEED-2014
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .