Pilot Clinical Investigation of Adaptative Eyeglasses for the Correction of Presbyopia (eve-1)
2022년 4월 6일 업데이트: Laclaree
Pilot Clinical Investigation of Adaptive Eyeglasses for the Correction of Presbyopia
This study is a pilot clinical investigation of adaptive eyeglasses for the correction of presbyopia.
The goal of this clinical investigation is to assess IMD safety and to obtain patient feedback on the usefulness of the Laclarée eyeglasses, through subjective clinical measures and qualitative evaluations.
This is an exploratory investigation.
연구 개요
상세 설명
Presbyopia is a visual impairment caused by the normal aging of the eye lens and resulting in progressive loss of accommodation.
As a consequence, from the onset of presbyopia occurring around 40-45 years old, the eye has growing trouble focusing at near and intermediate distances.
Millions of presbyopes encounter difficulties with current corrective solutions, leading to vision and postural discomfort.
Laclarée's adaptive eyeglasses are providing an alternative solution, closer to the native crystalline accommodation.
Besides an enhanced field-of-view, these eyeglasses offer a disruptive ergonomics where the glasses automatically adjust to the wearer's need to provide clear vision at all distances and can be electronically recalibrated to adjust the delivered addition throughout presbyopia.
연구 유형
중재적
등록 (실제)
40
단계
- 해당 없음
연락처 및 위치
이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.
연구 장소
-
-
-
Saint-Étienne, 프랑스, 42055
- CHU Saint-Etienne Hôpital Nord, Service d'Ophtalmologie 25, boulevard Pasteur
-
-
참여기준
연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.
자격 기준
공부할 수 있는 나이
- 어린이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
아니
연구 대상 성별
모두
설명
Inclusion Criteria:
- Patient >18 years of age, male or female who has given explicit informed consent (dated and signed)
- Diagnosed with presbyopia
- A wearer whose current corrective solution is a pair of progressive lenses that provide clear vision at both distance and near vision (worn at least 5 times per week for 4 hours per day), or, a wearer who has rejected progressive glasses that provide clear vision at both distance and near vision and who uses another corrective solution that provides clear vision at both distance and near vision (bifocal glasses, multifocal or monovision lenses, multiple pairs of glasses or one pair for cases of emmetropia)
- Patient with a distance visual acuity of 10/10 at least with current corrective solution
- Patient with a visual acuity of P2 at least in near vision with current corrective solution
- Patient with at least 10/10 distance vision once corrected with contact lenses for the test
- Inter-pupillary distance in distance vision between 55 and 71mm
- Distance from temple-to-temple not exceeding 161mm
- Addition greater than or equal to 1.75D: Add≥1.75D
- Sphere strictly between -6D and +4D: -6D<S<+4D
- Cylinder below 1.75D:C<1.75D
- Patient uses a computer (at least 3 times a week in private and/or work settings).
- Affiliation to a social security scheme
- French-speaking (fluent).
- Patient willing to participate in the study.
Exclusion Criteria:
- Patient under tutorship or guardianship.
- Patient unable to understand the study procedures and therefore to provide free and informed consent
- Patient with reading difficulties
- Patient with multifocal implants
- Patient who has undergone multifocal surgery
- Patient with prism correction
- Patient with a current or past eye condition that may adversely affect vision
- Patient being treated or having undergone surgery likely to adversely affect vision
- Patient with mobility problems that would prevent tests and workshops from being carried out
- Patient intolerant to wearing contact lenses for a few hours (only for presbyopes with ametropia)
- Patient who is pregnant or breastfeeding
- Patient already included once in the study
- Patient placed in an institution based on a judicial or regulatory ruling, held in psychiatric department, in state-run prison, or employed by the study research sites or by the sponsor.
공부 계획
이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 지지 요법
- 할당: 무작위
- 중재 모델: 크로스오버 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
다른: First Arm
|
The tested investigational medical device is a prototype of semi-integrated eyeglasses.
The comparator is either a pair of progressive lenses that provide clear vision at both distance and near vision, either, for wearers who have rejected progressive glasses, an alternative solution providing clear vision at both distance and near vision which can consist of bifocal glasses, multifocal or monovision lenses, multiple pairs of glasses or one pair for cases of emmetropia.
|
|
다른: Second Arm
|
The tested investigational medical device is a prototype of semi-integrated eyeglasses.
The comparator is either a pair of progressive lenses that provide clear vision at both distance and near vision, either, for wearers who have rejected progressive glasses, an alternative solution providing clear vision at both distance and near vision which can consist of bifocal glasses, multifocal or monovision lenses, multiple pairs of glasses or one pair for cases of emmetropia.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
IMD safety evaluation
기간: 2 hours
|
To evaluate the IMD safety : Collection of adverse events.
|
2 hours
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Exploratory evaluation of the IMD - controlled tests assessing visual acuity and performance on visual tasks
기간: 2 hours
|
To make an exploratory evaluation of the IMD performance on patient vision quality, when compared to that obtained with the patient usual personal eyewear (comparator) : Subjective measures on controlled tests assessing visual acuity and performance on visual tasks.
|
2 hours
|
|
Exploratory evaluation of the IMD - a questionnaire assessing vision quality
기간: 2 hours
|
To make an exploratory evaluation of the IMD performance on patient vision quality, when compared to that obtained with the patient usual personal eyewear (comparator) : Subjective measures on questionnaires.
|
2 hours
|
|
Exploratory evaluation of the IMD - patient qualitative feedback
기간: 2 hours
|
To make an exploratory evaluation of the IMD performance on patient vision quality, when compared to that obtained with the patient usual personal eyewear (comparator) : Collection of patient feedback.
|
2 hours
|
공동 작업자 및 조사자
여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.
스폰서
협력자
수사관
- 연구 의자: Bruno BERGE, PhD, SPONSOR: LACLAREE
- 연구 책임자: Jessica JAROSZ, PhD, SPONSOR: LACLAREE
- 수석 연구원: Philippe GAIN, Prof., CHU Saint-étienne
간행물 및 유용한 링크
연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.
유용한 링크
- Jessica Jarosz, Norbert Molliex, Guilhem Chenon, and Bruno Berge, "Adaptive eyeglasses for presbyopia correction: an original variable-focus technology," Opt. Express 27, 10533-10552 (2019)
- Jessica Jarosz, Norbert Molliex, Quentin Lavigne, and Bruno Berge "An original low-power opto-fluidic engine for presbyopia-correcting adaptive eyeglasses", Proc. SPIE 10858, Ophthalmic Technologies XXIX, 1085824 (28 February 2019)
연구 기록 날짜
이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.
연구 주요 날짜
연구 시작 (실제)
2021년 9월 9일
기본 완료 (실제)
2022년 1월 27일
연구 완료 (실제)
2022년 1월 27일
연구 등록 날짜
최초 제출
2022년 3월 1일
QC 기준을 충족하는 최초 제출
2022년 4월 6일
처음 게시됨 (실제)
2022년 4월 13일
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
2022년 4월 13일
QC 기준을 충족하는 마지막 업데이트 제출
2022년 4월 6일
마지막으로 확인됨
2022년 4월 1일
추가 정보