- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT05326607
Pilot Clinical Investigation of Adaptative Eyeglasses for the Correction of Presbyopia (eve-1)
6 de abril de 2022 atualizado por: Laclaree
Pilot Clinical Investigation of Adaptive Eyeglasses for the Correction of Presbyopia
This study is a pilot clinical investigation of adaptive eyeglasses for the correction of presbyopia.
The goal of this clinical investigation is to assess IMD safety and to obtain patient feedback on the usefulness of the Laclarée eyeglasses, through subjective clinical measures and qualitative evaluations.
This is an exploratory investigation.
Visão geral do estudo
Status
Concluído
Condições
Intervenção / Tratamento
Descrição detalhada
Presbyopia is a visual impairment caused by the normal aging of the eye lens and resulting in progressive loss of accommodation.
As a consequence, from the onset of presbyopia occurring around 40-45 years old, the eye has growing trouble focusing at near and intermediate distances.
Millions of presbyopes encounter difficulties with current corrective solutions, leading to vision and postural discomfort.
Laclarée's adaptive eyeglasses are providing an alternative solution, closer to the native crystalline accommodation.
Besides an enhanced field-of-view, these eyeglasses offer a disruptive ergonomics where the glasses automatically adjust to the wearer's need to provide clear vision at all distances and can be electronically recalibrated to adjust the delivered addition throughout presbyopia.
Tipo de estudo
Intervencional
Inscrição (Real)
40
Estágio
- Não aplicável
Contactos e Locais
Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.
Locais de estudo
-
-
-
Saint-Étienne, França, 42055
- CHU Saint-Etienne Hôpital Nord, Service d'Ophtalmologie 25, boulevard Pasteur
-
-
Critérios de participação
Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.
Critérios de elegibilidade
Idades elegíveis para estudo
- Filho
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Não
Gêneros Elegíveis para o Estudo
Tudo
Descrição
Inclusion Criteria:
- Patient >18 years of age, male or female who has given explicit informed consent (dated and signed)
- Diagnosed with presbyopia
- A wearer whose current corrective solution is a pair of progressive lenses that provide clear vision at both distance and near vision (worn at least 5 times per week for 4 hours per day), or, a wearer who has rejected progressive glasses that provide clear vision at both distance and near vision and who uses another corrective solution that provides clear vision at both distance and near vision (bifocal glasses, multifocal or monovision lenses, multiple pairs of glasses or one pair for cases of emmetropia)
- Patient with a distance visual acuity of 10/10 at least with current corrective solution
- Patient with a visual acuity of P2 at least in near vision with current corrective solution
- Patient with at least 10/10 distance vision once corrected with contact lenses for the test
- Inter-pupillary distance in distance vision between 55 and 71mm
- Distance from temple-to-temple not exceeding 161mm
- Addition greater than or equal to 1.75D: Add≥1.75D
- Sphere strictly between -6D and +4D: -6D<S<+4D
- Cylinder below 1.75D:C<1.75D
- Patient uses a computer (at least 3 times a week in private and/or work settings).
- Affiliation to a social security scheme
- French-speaking (fluent).
- Patient willing to participate in the study.
Exclusion Criteria:
- Patient under tutorship or guardianship.
- Patient unable to understand the study procedures and therefore to provide free and informed consent
- Patient with reading difficulties
- Patient with multifocal implants
- Patient who has undergone multifocal surgery
- Patient with prism correction
- Patient with a current or past eye condition that may adversely affect vision
- Patient being treated or having undergone surgery likely to adversely affect vision
- Patient with mobility problems that would prevent tests and workshops from being carried out
- Patient intolerant to wearing contact lenses for a few hours (only for presbyopes with ametropia)
- Patient who is pregnant or breastfeeding
- Patient already included once in the study
- Patient placed in an institution based on a judicial or regulatory ruling, held in psychiatric department, in state-run prison, or employed by the study research sites or by the sponsor.
Plano de estudo
Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Cuidados de suporte
- Alocação: Randomizado
- Modelo Intervencional: Atribuição cruzada
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Outro: First Arm
|
The tested investigational medical device is a prototype of semi-integrated eyeglasses.
The comparator is either a pair of progressive lenses that provide clear vision at both distance and near vision, either, for wearers who have rejected progressive glasses, an alternative solution providing clear vision at both distance and near vision which can consist of bifocal glasses, multifocal or monovision lenses, multiple pairs of glasses or one pair for cases of emmetropia.
|
|
Outro: Second Arm
|
The tested investigational medical device is a prototype of semi-integrated eyeglasses.
The comparator is either a pair of progressive lenses that provide clear vision at both distance and near vision, either, for wearers who have rejected progressive glasses, an alternative solution providing clear vision at both distance and near vision which can consist of bifocal glasses, multifocal or monovision lenses, multiple pairs of glasses or one pair for cases of emmetropia.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
IMD safety evaluation
Prazo: 2 hours
|
To evaluate the IMD safety : Collection of adverse events.
|
2 hours
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Exploratory evaluation of the IMD - controlled tests assessing visual acuity and performance on visual tasks
Prazo: 2 hours
|
To make an exploratory evaluation of the IMD performance on patient vision quality, when compared to that obtained with the patient usual personal eyewear (comparator) : Subjective measures on controlled tests assessing visual acuity and performance on visual tasks.
|
2 hours
|
|
Exploratory evaluation of the IMD - a questionnaire assessing vision quality
Prazo: 2 hours
|
To make an exploratory evaluation of the IMD performance on patient vision quality, when compared to that obtained with the patient usual personal eyewear (comparator) : Subjective measures on questionnaires.
|
2 hours
|
|
Exploratory evaluation of the IMD - patient qualitative feedback
Prazo: 2 hours
|
To make an exploratory evaluation of the IMD performance on patient vision quality, when compared to that obtained with the patient usual personal eyewear (comparator) : Collection of patient feedback.
|
2 hours
|
Colaboradores e Investigadores
É aqui que você encontrará pessoas e organizações envolvidas com este estudo.
Patrocinador
Colaboradores
Investigadores
- Cadeira de estudo: Bruno BERGE, PhD, SPONSOR: LACLAREE
- Diretor de estudo: Jessica JAROSZ, PhD, SPONSOR: LACLAREE
- Investigador principal: Philippe GAIN, Prof., Chu Saint-Etienne
Publicações e links úteis
A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.
Links úteis
- Jessica Jarosz, Norbert Molliex, Guilhem Chenon, and Bruno Berge, "Adaptive eyeglasses for presbyopia correction: an original variable-focus technology," Opt. Express 27, 10533-10552 (2019)
- Jessica Jarosz, Norbert Molliex, Quentin Lavigne, and Bruno Berge "An original low-power opto-fluidic engine for presbyopia-correcting adaptive eyeglasses", Proc. SPIE 10858, Ophthalmic Technologies XXIX, 1085824 (28 February 2019)
Datas de registro do estudo
Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.
Datas Principais do Estudo
Início do estudo (Real)
9 de setembro de 2021
Conclusão Primária (Real)
27 de janeiro de 2022
Conclusão do estudo (Real)
27 de janeiro de 2022
Datas de inscrição no estudo
Enviado pela primeira vez
1 de março de 2022
Enviado pela primeira vez que atendeu aos critérios de CQ
6 de abril de 2022
Primeira postagem (Real)
13 de abril de 2022
Atualizações de registro de estudo
Última Atualização Postada (Real)
13 de abril de 2022
Última atualização enviada que atendeu aos critérios de controle de qualidade
6 de abril de 2022
Última verificação
1 de abril de 2022
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 2021-A00521-40
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
NÃO
Descrição do plano IPD
Not planned
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Não
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Não
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .