이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

The Effects of Low-Flow and Normal-Flow Sevoflurane Anesthesia on Frontal QRS-T Angle and TP-e Interval

2026년 4월 30일 업데이트: Cansu UZUNTURK, Istanbul University

The Effects of Low-Flow and Normal-Flow Sevoflurane Anesthesia on Frontal QRS-T Angle and TP-e Interval in Patients Undergoing Elective Laparoscopic Cholecystectomy

Laparoscopic cholecystectomy procedures involve pneumoperitoneum and volatile anesthetics, both of which can significantly influence cardiovascular physiology and autonomic balance. While volatile anesthetics are known to affect myocardial repolarization, the specific impact of Low-Flow Anesthesia (LFA)-a cost-effective and environmentally friendly technique-on these cardiac markers remains under-researched.

This prospective observational study aims to compare the effects of low-flow versus normal-flow sevoflurane anesthesia on two critical non-invasive biomarkers of ventricular repolarization: the Frontal QRS-T angle and the Tp-e interval. These parameters are essential for predicting electrical instability and the risk of malignant arrhythmias. The study will evaluate a total of 128 patients to determine whether different fresh gas flow rates lead to significant changes in cardiac electrophysiological stability during the perioperative and early postoperative periods.

연구 개요

상태

아직 모집하지 않음

상세 설명

This prospective observational study is designed to investigate the electrophysiological effects of different fresh gas flow rates during sevoflurane anesthesia in patients undergoing elective laparoscopic cholecystectomy. Laparoscopic procedures involving pneumoperitoneum and volatile anesthetics are known to influence autonomic nervous system balance and cardiovascular stability. While the impact of inhalation agents on myocardial repolarization is documented, the specific effects of Low-Flow Anesthesia (LFA)-an environmentally and economically favorable technique-on markers of electrical instability remain to be fully elucidated. The primary objective is to evaluate and compare the effects of low-flow and normal-flow sevoflurane techniques on the Frontal QRS-T angle and the Tp-e interval, which serve as critical non-invasive biomarkers for predicting malignant arrhythmia risk and reflecting the transmural distribution of ventricular repolarization.

The study protocol involves 128 patients, a sample size determined by power analysis (80% power, 0.05 alpha) to account for a predicted 35% difference between groups and potential dropouts. Patients are observationally assigned to either the Low-Flow Group (LFG) or the Normal-Flow Group (NFG) according to routine clinical practice. Following a standardized induction and an initial stabilization phase at 4-6 L/min, flow rates are adjusted once the target concentration (MACage +1) is reached: the LFG is reduced to 0.5 L/min, while the NFG is maintained at 2 L/min. Ventilation is managed to keep EtCO2 between 35-45 mmHg. Data collection is performed via high-resolution ECG recordings at four time points: preoperative baseline (T1), 5 minutes post-intubation (T2), 15 minutes post-intubation (T3), and 15 minutes postoperatively (T4).

Another key focus of this research is the detailed analysis of secondary outcomes, including the monitoring of hemodynamic stability (mean arterial pressure and heart rate) across all time points. Furthermore, the study aims to characterize the electrophysiological profile of each technique by analyzing the Tp-e/QT ratio and calculating time-dependent variations in repolarization parameters, specifically the delta changes from baseline to intraoperative stages (ΔT1-T2 and ΔT1-T3). Additionally, a cost-effectiveness analysis will be conducted by determining the total volume of volatile anesthetic consumed in both techniques. Statistical analysis will involve independent samples t-tests for inter-group comparisons, while repeated measures ANOVA with Bonferroni correction will evaluate time-dependent changes. Pearson correlation analysis will be utilized to assess the relationships between continuous variables, providing a comprehensive assessment of the safety and efficacy of low-flow versus normal-flow anesthesia management.

연구 유형

관찰

등록 (추정된)

128

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인
  • 고령자

건강한 자원 봉사자를 받아들입니다

예

샘플링 방법

확률 샘플

연구 인구

The study population consists of adult patients (aged 18 years and older) scheduled for elective or semi-elective laparoscopic cholecystectomy at a tertiary care training and research hospital.

설명

Inclusion Criteria:

  • Patients aged 18 years and older.
  • Patients scheduled for elective or semi-elective laparoscopic cholecystectomy.
  • Patients who provide written voluntary informed consent.
  • Patients with a predicted surgical duration between 60 and 180 minutes.

Exclusion Criteria:

  • Patients with heart failure.
  • Patients with valvular heart disease or pathology.
  • Patients with hemodynamic instability.
  • Patients requiring blood transfusion.
  • Patients with a preoperative corrected QT (QTc) interval > 450 ms.
  • Patients with a known history of cardiac arrhythmia.
  • Patients scheduled for emergency surgery.
  • Patients with a known risk or family history of malignant hyperthermia.
  • Use of medications associated with QT interval prolongation (e.g., ketamine, 5-HT3 antagonists, quetiapine, etc.).

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

코호트 및 개입

그룹/코호트
개입 / 치료
Low-Flow Group (LFG)
Anesthesia induction and initial stabilization (first 6-8 minutes at 4-6 L/min) follow standard hospital protocols. Fresh Gas Flow (FGF) reduced to 0.5 L/min after the target concentration (MACage +1) is reached. Ventilation parameters are adjusted to maintain end-tidal carbon dioxide (EtCO2) between 35-45 mmHg with a minimum FiO2 of 0.30. Volatile anesthetics are discontinued 15 minutes before the estimated end of surgery. Pre-oxygenation and wash-out are performed at 5-6 L/min with 80% oxygen prior to extubation.
Fresh Gas Flow (FGF) reduced to 0.5 L/min after the target concentration (MACage +1) is reached.
Normal-Flow Group (NFG)
Anesthesia induction and initial stabilization (first 6-8 minutes at 4-6 L/min) follow standard hospital protocols. Fresh Gas Flow (FGF) maintained at 2 L/min during anesthesia maintenance. Ventilation parameters are adjusted to maintain end-tidal carbon dioxide (EtCO2) between 35-45 mmHg with a minimum FiO2 of 0.30. Volatile anesthetics are discontinued 15 minutes before the estimated end of surgery. Pre-oxygenation and wash-out are performed at 5-6 L/min with 80% oxygen prior to extubation.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Frontal QRS-T angle
기간: Pre-operative period, 5 minutes after induction, 15 minutes after induction, post operative 15th minute
electrocardiogram
Pre-operative period, 5 minutes after induction, 15 minutes after induction, post operative 15th minute
Tp-e interval
기간: Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute
electrocardiogram
Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute

2차 결과 측정

결과 측정
측정값 설명
기간
blood pressure
기간: during peri-operative period
Non-invasive blood pressure (NIBP) monitor
during peri-operative period
heart rate
기간: during peri-operative period
electrocardiogram
during peri-operative period
Tp-e/QT ratio
기간: Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute
electrocardiogram
Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute
Total amount of volatile anesthetic consumed
기간: end of operation
Mindray anesthesia machine
end of operation
Total amount of Remifentanil consumed
기간: end of operation
infusion pump
end of operation

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (추정된)

2026년 5월 15일

기본 완료 (추정된)

2027년 5월 15일

연구 완료 (추정된)

2027년 8월 15일

연구 등록 날짜

최초 제출

2026년 4월 30일

QC 기준을 충족하는 최초 제출

2026년 4월 30일

처음 게시됨 (실제)

2026년 5월 7일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 5월 7일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 4월 30일

마지막으로 확인됨

2026년 4월 1일

추가 정보

이 연구와 관련된 용어

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다