Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

The Effects of Low-Flow and Normal-Flow Sevoflurane Anesthesia on Frontal QRS-T Angle and TP-e Interval

30 de abril de 2026 atualizado por: Cansu UZUNTURK, Istanbul University

The Effects of Low-Flow and Normal-Flow Sevoflurane Anesthesia on Frontal QRS-T Angle and TP-e Interval in Patients Undergoing Elective Laparoscopic Cholecystectomy

Laparoscopic cholecystectomy procedures involve pneumoperitoneum and volatile anesthetics, both of which can significantly influence cardiovascular physiology and autonomic balance. While volatile anesthetics are known to affect myocardial repolarization, the specific impact of Low-Flow Anesthesia (LFA)-a cost-effective and environmentally friendly technique-on these cardiac markers remains under-researched.

This prospective observational study aims to compare the effects of low-flow versus normal-flow sevoflurane anesthesia on two critical non-invasive biomarkers of ventricular repolarization: the Frontal QRS-T angle and the Tp-e interval. These parameters are essential for predicting electrical instability and the risk of malignant arrhythmias. The study will evaluate a total of 128 patients to determine whether different fresh gas flow rates lead to significant changes in cardiac electrophysiological stability during the perioperative and early postoperative periods.

Visão geral do estudo

Status

Ainda não está recrutando

Intervenção / Tratamento

Descrição detalhada

This prospective observational study is designed to investigate the electrophysiological effects of different fresh gas flow rates during sevoflurane anesthesia in patients undergoing elective laparoscopic cholecystectomy. Laparoscopic procedures involving pneumoperitoneum and volatile anesthetics are known to influence autonomic nervous system balance and cardiovascular stability. While the impact of inhalation agents on myocardial repolarization is documented, the specific effects of Low-Flow Anesthesia (LFA)-an environmentally and economically favorable technique-on markers of electrical instability remain to be fully elucidated. The primary objective is to evaluate and compare the effects of low-flow and normal-flow sevoflurane techniques on the Frontal QRS-T angle and the Tp-e interval, which serve as critical non-invasive biomarkers for predicting malignant arrhythmia risk and reflecting the transmural distribution of ventricular repolarization.

The study protocol involves 128 patients, a sample size determined by power analysis (80% power, 0.05 alpha) to account for a predicted 35% difference between groups and potential dropouts. Patients are observationally assigned to either the Low-Flow Group (LFG) or the Normal-Flow Group (NFG) according to routine clinical practice. Following a standardized induction and an initial stabilization phase at 4-6 L/min, flow rates are adjusted once the target concentration (MACage +1) is reached: the LFG is reduced to 0.5 L/min, while the NFG is maintained at 2 L/min. Ventilation is managed to keep EtCO2 between 35-45 mmHg. Data collection is performed via high-resolution ECG recordings at four time points: preoperative baseline (T1), 5 minutes post-intubation (T2), 15 minutes post-intubation (T3), and 15 minutes postoperatively (T4).

Another key focus of this research is the detailed analysis of secondary outcomes, including the monitoring of hemodynamic stability (mean arterial pressure and heart rate) across all time points. Furthermore, the study aims to characterize the electrophysiological profile of each technique by analyzing the Tp-e/QT ratio and calculating time-dependent variations in repolarization parameters, specifically the delta changes from baseline to intraoperative stages (ΔT1-T2 and ΔT1-T3). Additionally, a cost-effectiveness analysis will be conducted by determining the total volume of volatile anesthetic consumed in both techniques. Statistical analysis will involve independent samples t-tests for inter-group comparisons, while repeated measures ANOVA with Bonferroni correction will evaluate time-dependent changes. Pearson correlation analysis will be utilized to assess the relationships between continuous variables, providing a comprehensive assessment of the safety and efficacy of low-flow versus normal-flow anesthesia management.

Tipo de estudo

Observacional

Inscrição (Estimado)

128

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Sim

Método de amostragem

Amostra de Probabilidade

População do estudo

The study population consists of adult patients (aged 18 years and older) scheduled for elective or semi-elective laparoscopic cholecystectomy at a tertiary care training and research hospital.

Descrição

Inclusion Criteria:

  • Patients aged 18 years and older.
  • Patients scheduled for elective or semi-elective laparoscopic cholecystectomy.
  • Patients who provide written voluntary informed consent.
  • Patients with a predicted surgical duration between 60 and 180 minutes.

Exclusion Criteria:

  • Patients with heart failure.
  • Patients with valvular heart disease or pathology.
  • Patients with hemodynamic instability.
  • Patients requiring blood transfusion.
  • Patients with a preoperative corrected QT (QTc) interval > 450 ms.
  • Patients with a known history of cardiac arrhythmia.
  • Patients scheduled for emergency surgery.
  • Patients with a known risk or family history of malignant hyperthermia.
  • Use of medications associated with QT interval prolongation (e.g., ketamine, 5-HT3 antagonists, quetiapine, etc.).

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

Coortes e Intervenções

Grupo / Coorte
Intervenção / Tratamento
Low-Flow Group (LFG)
Anesthesia induction and initial stabilization (first 6-8 minutes at 4-6 L/min) follow standard hospital protocols. Fresh Gas Flow (FGF) reduced to 0.5 L/min after the target concentration (MACage +1) is reached. Ventilation parameters are adjusted to maintain end-tidal carbon dioxide (EtCO2) between 35-45 mmHg with a minimum FiO2 of 0.30. Volatile anesthetics are discontinued 15 minutes before the estimated end of surgery. Pre-oxygenation and wash-out are performed at 5-6 L/min with 80% oxygen prior to extubation.
Fresh Gas Flow (FGF) reduced to 0.5 L/min after the target concentration (MACage +1) is reached.
Normal-Flow Group (NFG)
Anesthesia induction and initial stabilization (first 6-8 minutes at 4-6 L/min) follow standard hospital protocols. Fresh Gas Flow (FGF) maintained at 2 L/min during anesthesia maintenance. Ventilation parameters are adjusted to maintain end-tidal carbon dioxide (EtCO2) between 35-45 mmHg with a minimum FiO2 of 0.30. Volatile anesthetics are discontinued 15 minutes before the estimated end of surgery. Pre-oxygenation and wash-out are performed at 5-6 L/min with 80% oxygen prior to extubation.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Frontal QRS-T angle
Prazo: Pre-operative period, 5 minutes after induction, 15 minutes after induction, post operative 15th minute
electrocardiogram
Pre-operative period, 5 minutes after induction, 15 minutes after induction, post operative 15th minute
Tp-e interval
Prazo: Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute
electrocardiogram
Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
blood pressure
Prazo: during peri-operative period
Non-invasive blood pressure (NIBP) monitor
during peri-operative period
heart rate
Prazo: during peri-operative period
electrocardiogram
during peri-operative period
Tp-e/QT ratio
Prazo: Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute
electrocardiogram
Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute
Total amount of volatile anesthetic consumed
Prazo: end of operation
Mindray anesthesia machine
end of operation
Total amount of Remifentanil consumed
Prazo: end of operation
infusion pump
end of operation

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

15 de maio de 2026

Conclusão Primária (Estimado)

15 de maio de 2027

Conclusão do estudo (Estimado)

15 de agosto de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

30 de abril de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

30 de abril de 2026

Primeira postagem (Real)

7 de maio de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

7 de maio de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

30 de abril de 2026

Última verificação

1 de abril de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • 96-2026

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever