Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

The Effects of Low-Flow and Normal-Flow Sevoflurane Anesthesia on Frontal QRS-T Angle and TP-e Interval

30. April 2026 aktualisiert von: Cansu UZUNTURK, Istanbul University

The Effects of Low-Flow and Normal-Flow Sevoflurane Anesthesia on Frontal QRS-T Angle and TP-e Interval in Patients Undergoing Elective Laparoscopic Cholecystectomy

Laparoscopic cholecystectomy procedures involve pneumoperitoneum and volatile anesthetics, both of which can significantly influence cardiovascular physiology and autonomic balance. While volatile anesthetics are known to affect myocardial repolarization, the specific impact of Low-Flow Anesthesia (LFA)-a cost-effective and environmentally friendly technique-on these cardiac markers remains under-researched.

This prospective observational study aims to compare the effects of low-flow versus normal-flow sevoflurane anesthesia on two critical non-invasive biomarkers of ventricular repolarization: the Frontal QRS-T angle and the Tp-e interval. These parameters are essential for predicting electrical instability and the risk of malignant arrhythmias. The study will evaluate a total of 128 patients to determine whether different fresh gas flow rates lead to significant changes in cardiac electrophysiological stability during the perioperative and early postoperative periods.

Studienübersicht

Status

Noch keine Rekrutierung

Intervention / Behandlung

Detaillierte Beschreibung

This prospective observational study is designed to investigate the electrophysiological effects of different fresh gas flow rates during sevoflurane anesthesia in patients undergoing elective laparoscopic cholecystectomy. Laparoscopic procedures involving pneumoperitoneum and volatile anesthetics are known to influence autonomic nervous system balance and cardiovascular stability. While the impact of inhalation agents on myocardial repolarization is documented, the specific effects of Low-Flow Anesthesia (LFA)-an environmentally and economically favorable technique-on markers of electrical instability remain to be fully elucidated. The primary objective is to evaluate and compare the effects of low-flow and normal-flow sevoflurane techniques on the Frontal QRS-T angle and the Tp-e interval, which serve as critical non-invasive biomarkers for predicting malignant arrhythmia risk and reflecting the transmural distribution of ventricular repolarization.

The study protocol involves 128 patients, a sample size determined by power analysis (80% power, 0.05 alpha) to account for a predicted 35% difference between groups and potential dropouts. Patients are observationally assigned to either the Low-Flow Group (LFG) or the Normal-Flow Group (NFG) according to routine clinical practice. Following a standardized induction and an initial stabilization phase at 4-6 L/min, flow rates are adjusted once the target concentration (MACage +1) is reached: the LFG is reduced to 0.5 L/min, while the NFG is maintained at 2 L/min. Ventilation is managed to keep EtCO2 between 35-45 mmHg. Data collection is performed via high-resolution ECG recordings at four time points: preoperative baseline (T1), 5 minutes post-intubation (T2), 15 minutes post-intubation (T3), and 15 minutes postoperatively (T4).

Another key focus of this research is the detailed analysis of secondary outcomes, including the monitoring of hemodynamic stability (mean arterial pressure and heart rate) across all time points. Furthermore, the study aims to characterize the electrophysiological profile of each technique by analyzing the Tp-e/QT ratio and calculating time-dependent variations in repolarization parameters, specifically the delta changes from baseline to intraoperative stages (ΔT1-T2 and ΔT1-T3). Additionally, a cost-effectiveness analysis will be conducted by determining the total volume of volatile anesthetic consumed in both techniques. Statistical analysis will involve independent samples t-tests for inter-group comparisons, while repeated measures ANOVA with Bonferroni correction will evaluate time-dependent changes. Pearson correlation analysis will be utilized to assess the relationships between continuous variables, providing a comprehensive assessment of the safety and efficacy of low-flow versus normal-flow anesthesia management.

Studientyp

Beobachtungs

Einschreibung (Geschätzt)

128

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Ja

Probenahmeverfahren

Wahrscheinlichkeitsstichprobe

Studienpopulation

The study population consists of adult patients (aged 18 years and older) scheduled for elective or semi-elective laparoscopic cholecystectomy at a tertiary care training and research hospital.

Beschreibung

Inclusion Criteria:

  • Patients aged 18 years and older.
  • Patients scheduled for elective or semi-elective laparoscopic cholecystectomy.
  • Patients who provide written voluntary informed consent.
  • Patients with a predicted surgical duration between 60 and 180 minutes.

Exclusion Criteria:

  • Patients with heart failure.
  • Patients with valvular heart disease or pathology.
  • Patients with hemodynamic instability.
  • Patients requiring blood transfusion.
  • Patients with a preoperative corrected QT (QTc) interval > 450 ms.
  • Patients with a known history of cardiac arrhythmia.
  • Patients scheduled for emergency surgery.
  • Patients with a known risk or family history of malignant hyperthermia.
  • Use of medications associated with QT interval prolongation (e.g., ketamine, 5-HT3 antagonists, quetiapine, etc.).

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

Kohorten und Interventionen

Gruppe / Kohorte
Intervention / Behandlung
Low-Flow Group (LFG)
Anesthesia induction and initial stabilization (first 6-8 minutes at 4-6 L/min) follow standard hospital protocols. Fresh Gas Flow (FGF) reduced to 0.5 L/min after the target concentration (MACage +1) is reached. Ventilation parameters are adjusted to maintain end-tidal carbon dioxide (EtCO2) between 35-45 mmHg with a minimum FiO2 of 0.30. Volatile anesthetics are discontinued 15 minutes before the estimated end of surgery. Pre-oxygenation and wash-out are performed at 5-6 L/min with 80% oxygen prior to extubation.
Fresh Gas Flow (FGF) reduced to 0.5 L/min after the target concentration (MACage +1) is reached.
Normal-Flow Group (NFG)
Anesthesia induction and initial stabilization (first 6-8 minutes at 4-6 L/min) follow standard hospital protocols. Fresh Gas Flow (FGF) maintained at 2 L/min during anesthesia maintenance. Ventilation parameters are adjusted to maintain end-tidal carbon dioxide (EtCO2) between 35-45 mmHg with a minimum FiO2 of 0.30. Volatile anesthetics are discontinued 15 minutes before the estimated end of surgery. Pre-oxygenation and wash-out are performed at 5-6 L/min with 80% oxygen prior to extubation.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Frontal QRS-T angle
Zeitfenster: Pre-operative period, 5 minutes after induction, 15 minutes after induction, post operative 15th minute
electrocardiogram
Pre-operative period, 5 minutes after induction, 15 minutes after induction, post operative 15th minute
Tp-e interval
Zeitfenster: Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute
electrocardiogram
Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
blood pressure
Zeitfenster: during peri-operative period
Non-invasive blood pressure (NIBP) monitor
during peri-operative period
heart rate
Zeitfenster: during peri-operative period
electrocardiogram
during peri-operative period
Tp-e/QT ratio
Zeitfenster: Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute
electrocardiogram
Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute
Total amount of volatile anesthetic consumed
Zeitfenster: end of operation
Mindray anesthesia machine
end of operation
Total amount of Remifentanil consumed
Zeitfenster: end of operation
infusion pump
end of operation

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Publikationen und hilfreiche Links

Die Bereitstellung dieser Publikationen erfolgt freiwillig durch die für die Eingabe von Informationen über die Studie verantwortliche Person. Diese können sich auf alles beziehen, was mit dem Studium zu tun hat.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

15. Mai 2026

Primärer Abschluss (Geschätzt)

15. Mai 2027

Studienabschluss (Geschätzt)

15. August 2027

Studienanmeldedaten

Zuerst eingereicht

30. April 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

30. April 2026

Zuerst gepostet (Tatsächlich)

7. Mai 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

7. Mai 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

30. April 2026

Zuletzt verifiziert

1. April 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren