Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

The Effects of Low-Flow and Normal-Flow Sevoflurane Anesthesia on Frontal QRS-T Angle and TP-e Interval

30 de abril de 2026 actualizado por: Cansu UZUNTURK, Istanbul University

The Effects of Low-Flow and Normal-Flow Sevoflurane Anesthesia on Frontal QRS-T Angle and TP-e Interval in Patients Undergoing Elective Laparoscopic Cholecystectomy

Laparoscopic cholecystectomy procedures involve pneumoperitoneum and volatile anesthetics, both of which can significantly influence cardiovascular physiology and autonomic balance. While volatile anesthetics are known to affect myocardial repolarization, the specific impact of Low-Flow Anesthesia (LFA)-a cost-effective and environmentally friendly technique-on these cardiac markers remains under-researched.

This prospective observational study aims to compare the effects of low-flow versus normal-flow sevoflurane anesthesia on two critical non-invasive biomarkers of ventricular repolarization: the Frontal QRS-T angle and the Tp-e interval. These parameters are essential for predicting electrical instability and the risk of malignant arrhythmias. The study will evaluate a total of 128 patients to determine whether different fresh gas flow rates lead to significant changes in cardiac electrophysiological stability during the perioperative and early postoperative periods.

Descripción general del estudio

Estado

Aún no reclutando

Intervención / Tratamiento

Descripción detallada

This prospective observational study is designed to investigate the electrophysiological effects of different fresh gas flow rates during sevoflurane anesthesia in patients undergoing elective laparoscopic cholecystectomy. Laparoscopic procedures involving pneumoperitoneum and volatile anesthetics are known to influence autonomic nervous system balance and cardiovascular stability. While the impact of inhalation agents on myocardial repolarization is documented, the specific effects of Low-Flow Anesthesia (LFA)-an environmentally and economically favorable technique-on markers of electrical instability remain to be fully elucidated. The primary objective is to evaluate and compare the effects of low-flow and normal-flow sevoflurane techniques on the Frontal QRS-T angle and the Tp-e interval, which serve as critical non-invasive biomarkers for predicting malignant arrhythmia risk and reflecting the transmural distribution of ventricular repolarization.

The study protocol involves 128 patients, a sample size determined by power analysis (80% power, 0.05 alpha) to account for a predicted 35% difference between groups and potential dropouts. Patients are observationally assigned to either the Low-Flow Group (LFG) or the Normal-Flow Group (NFG) according to routine clinical practice. Following a standardized induction and an initial stabilization phase at 4-6 L/min, flow rates are adjusted once the target concentration (MACage +1) is reached: the LFG is reduced to 0.5 L/min, while the NFG is maintained at 2 L/min. Ventilation is managed to keep EtCO2 between 35-45 mmHg. Data collection is performed via high-resolution ECG recordings at four time points: preoperative baseline (T1), 5 minutes post-intubation (T2), 15 minutes post-intubation (T3), and 15 minutes postoperatively (T4).

Another key focus of this research is the detailed analysis of secondary outcomes, including the monitoring of hemodynamic stability (mean arterial pressure and heart rate) across all time points. Furthermore, the study aims to characterize the electrophysiological profile of each technique by analyzing the Tp-e/QT ratio and calculating time-dependent variations in repolarization parameters, specifically the delta changes from baseline to intraoperative stages (ΔT1-T2 and ΔT1-T3). Additionally, a cost-effectiveness analysis will be conducted by determining the total volume of volatile anesthetic consumed in both techniques. Statistical analysis will involve independent samples t-tests for inter-group comparisons, while repeated measures ANOVA with Bonferroni correction will evaluate time-dependent changes. Pearson correlation analysis will be utilized to assess the relationships between continuous variables, providing a comprehensive assessment of the safety and efficacy of low-flow versus normal-flow anesthesia management.

Tipo de estudio

De observación

Inscripción (Estimado)

128

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

Sí

Método de muestreo

Muestra de probabilidad

Población de estudio

The study population consists of adult patients (aged 18 years and older) scheduled for elective or semi-elective laparoscopic cholecystectomy at a tertiary care training and research hospital.

Descripción

Inclusion Criteria:

  • Patients aged 18 years and older.
  • Patients scheduled for elective or semi-elective laparoscopic cholecystectomy.
  • Patients who provide written voluntary informed consent.
  • Patients with a predicted surgical duration between 60 and 180 minutes.

Exclusion Criteria:

  • Patients with heart failure.
  • Patients with valvular heart disease or pathology.
  • Patients with hemodynamic instability.
  • Patients requiring blood transfusion.
  • Patients with a preoperative corrected QT (QTc) interval > 450 ms.
  • Patients with a known history of cardiac arrhythmia.
  • Patients scheduled for emergency surgery.
  • Patients with a known risk or family history of malignant hyperthermia.
  • Use of medications associated with QT interval prolongation (e.g., ketamine, 5-HT3 antagonists, quetiapine, etc.).

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

Cohortes e Intervenciones

Grupo / Cohorte
Intervención / Tratamiento
Low-Flow Group (LFG)
Anesthesia induction and initial stabilization (first 6-8 minutes at 4-6 L/min) follow standard hospital protocols. Fresh Gas Flow (FGF) reduced to 0.5 L/min after the target concentration (MACage +1) is reached. Ventilation parameters are adjusted to maintain end-tidal carbon dioxide (EtCO2) between 35-45 mmHg with a minimum FiO2 of 0.30. Volatile anesthetics are discontinued 15 minutes before the estimated end of surgery. Pre-oxygenation and wash-out are performed at 5-6 L/min with 80% oxygen prior to extubation.
Fresh Gas Flow (FGF) reduced to 0.5 L/min after the target concentration (MACage +1) is reached.
Normal-Flow Group (NFG)
Anesthesia induction and initial stabilization (first 6-8 minutes at 4-6 L/min) follow standard hospital protocols. Fresh Gas Flow (FGF) maintained at 2 L/min during anesthesia maintenance. Ventilation parameters are adjusted to maintain end-tidal carbon dioxide (EtCO2) between 35-45 mmHg with a minimum FiO2 of 0.30. Volatile anesthetics are discontinued 15 minutes before the estimated end of surgery. Pre-oxygenation and wash-out are performed at 5-6 L/min with 80% oxygen prior to extubation.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Frontal QRS-T angle
Periodo de tiempo: Pre-operative period, 5 minutes after induction, 15 minutes after induction, post operative 15th minute
electrocardiogram
Pre-operative period, 5 minutes after induction, 15 minutes after induction, post operative 15th minute
Tp-e interval
Periodo de tiempo: Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute
electrocardiogram
Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
blood pressure
Periodo de tiempo: during peri-operative period
Non-invasive blood pressure (NIBP) monitor
during peri-operative period
heart rate
Periodo de tiempo: during peri-operative period
electrocardiogram
during peri-operative period
Tp-e/QT ratio
Periodo de tiempo: Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute
electrocardiogram
Pre-operative period, 5 minutes after induction, 15 minutes after induction, post-operative 15th minute
Total amount of volatile anesthetic consumed
Periodo de tiempo: end of operation
Mindray anesthesia machine
end of operation
Total amount of Remifentanil consumed
Periodo de tiempo: end of operation
infusion pump
end of operation

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

15 de mayo de 2026

Finalización primaria (Estimado)

15 de mayo de 2027

Finalización del estudio (Estimado)

15 de agosto de 2027

Fechas de registro del estudio

Enviado por primera vez

30 de abril de 2026

Primero enviado que cumplió con los criterios de control de calidad

30 de abril de 2026

Publicado por primera vez (Actual)

7 de mayo de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

7 de mayo de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

30 de abril de 2026

Última verificación

1 de abril de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 96-2026

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir