- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07740265
Effect of Scanning Techniques on Accuracy of Mandibular Fixed Detachable Prostheses
Influence of Three Different Scanning Techniques on Scanning Accuracy for Mandibular Fixed Detachable Prosthesis (A Cross Over Study).
연구 개요
상태
상세 설명
This prospective crossover clinical trial is designed to evaluate and compare the accuracy and passive fit of three different intraoral scanning techniques used for the fabrication of mandibular implant-supported fixed detachable prostheses in completely edentulous patients.
The study will include completely edentulous participants rehabilitated with four osseointegrated implants placed in the mandibular arch. Each participant will undergo digital implant impression procedures using three different scanning .
The three scanning techniques being compared are:
- Splinted Scan Bodies: Implant scan bodies will be splinted using composite resin before intraoral scanning.
- Horizontal Non-Calibrated Scan Bodies (IO Connect): Digital impressions will be obtained using the IO Connect horizontal scan body system.
- Auxiliary Geometric Devices: Digital impressions will be acquired using 3D-printed auxiliary geometric devices attached to the scan bodies to provide additional geometric reference landmarks during scanning.
Digital datasets generated from each scanning technique will be analyzed and compared. Verification jigs will be fabricated using CAD/CAM technology and clinically evaluated.
The primary outcomes of the study are scanning accuracy, assessed by measuring linear deviation (µm) and angular deviation (degrees) between implant positions obtained from the different scanning techniques, and three-dimensional surface deviation analysis, assessed through root mean square (RMS) values and median surface deviation obtained from STL file superimposition.
The secondary outcome is passive fit , which will be evaluated using the Sheffield one-screw test and intraoral periapical radiographic assessment.
The findings of this study will help identify the scanning technique that provides the highest accuracy and best passive fit for mandibular implant-supported fixed detachable prostheses and may contribute to improving digital workflows in complete-arch implant rehabilitation.
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 연락처
- 이름: Mostafa Hamed Mostafa Abd El-Hameed Abd El-Hameed, BDS, MSc
- 전화번호: +201090461713
- 이메일: mostafa_hamed@dent.tanta.edu.eg
연구 장소
-
-
Gharbia Governorate
-
Tanta, Gharbia Governorate, 이집트, 31527
- 모병
- faculty of dentistry, Tanta university
-
연락하다:
- Mostafa Hamed Mostafa Abd El-Hameed
- 전화번호: +201090461713
- 이메일: mostafa_hamed@dent.tanta.edu.eg
-
수석 연구원:
- Mostafa Hamed Mostafa Abd El-Hameed, BDS, MSc
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria:
- Completely edentulous patients with age between 40-60 years.
- Adequate bone height to fulfill the criteria for implant placement.
- Patients should have a class I Angle's classification.
Exclusion Criteria:
1-. Insufficient vertical inter-arch space to accommodate the restorative components.
2. Presence of psychiatric or neurological conditions. 3. Any systemic diseases that may affect implant bone osteointegration.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 장치 타당성
- 할당: 무작위
- 중재 모델: 크로스오버 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: Splinted Scan Bodies with composite
Participants will undergo full-arch digital implant scanning using implant scan bodies splinted with composite resin.
The splinting procedure is intended to improve the stability of scan bodies and reduce positional discrepancies during digital impression acquisition.
|
A full-arch digital implant impression will be obtained using implant scan bodies splinted with composite resin prior to scanning.
The splinting procedure will provide enhanced scan body stability and will be used to minimize positional discrepancies during digital impression acquisition.
|
|
실험적: horizontal non-calibrated scan bodies
Participants will undergo full-arch digital implant scanning using horizontal non-calibrated scan bodies (IO Connect).
This technique utilizes a horizontal scan body design to facilitate implant position recognition, digital alignment, and complete-arch digital impression acquisition.
|
A full-arch digital implant impression will be obtained using horizontal non-calibrated scan bodies (IO Connect).
The horizontal scan body design will facilitate implant position recognition, digital alignment, and accurate transfer of implant coordinates throughout the digital impression procedure.
|
|
실험적: Auxiliary Geometric Device Scanning
Participants will undergo full-arch digital implant scanning using 3D-printed auxiliary geometric devices attached to implant scan bodies.
The auxiliary devices provide additional geometric reference landmarks intended to improve scanning accuracy and reduce stitching errors during complete-arch digital impressions.
|
A full-arch digital implant impression will be obtained using 3D-printed auxiliary geometric devices attached to implant scan bodies.
These auxiliary devices will provide additional geometric reference landmarks to improve stitching accuracy, reduce cumulative scanning errors, and enhance complete-arch digital impression accuracy.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Implant linear and angular deviation
기간: Immediately after completion of digital scanning day 0
|
The linear and angular deviations of implants will be compared and analyzed across different scanning techniques against each other
|
Immediately after completion of digital scanning day 0
|
|
Three-Dimensional part comparison
기간: Immediately after completion of digital scanning day 0
|
Three-dimensional surface deviation will be evaluated by uploading all STL files to dedicated comparison software.
Digital superimposition will be performed to calculate the median surface deviation and root mean square (RMS) values between the datasets, providing a quantitative assessment of surface discrepancies among the three scanning techniques.
|
Immediately after completion of digital scanning day 0
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
fit of verification jig
기간: Within 1 hour of fabrication and intraoral placement of the verification jig
|
Passive fit will be evaluated clinically using the Sheffield one-screw test and confirmed by intraoral periapical radiographs.
|
Within 1 hour of fabrication and intraoral placement of the verification jig
|
공동 작업자 및 조사자
스폰서
수사관
- 수석 연구원: Mostafa Hamed Mostafa Abd El-Hameed Abd El-Hameed, BDS, MSc, Faculty of Dentistry, Tanta University, Egypt
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
키워드
기타 연구 ID 번호
- RP-11-25-3482
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .