Effect of Scanning Techniques on Accuracy of Mandibular Fixed Detachable Prostheses
Influence of Three Different Scanning Techniques on Scanning Accuracy for Mandibular Fixed Detachable Prosthesis (A Cross Over Study).
Studieoversigt
Status
Betingelser
Detaljeret beskrivelse
This prospective crossover clinical trial is designed to evaluate and compare the accuracy and passive fit of three different intraoral scanning techniques used for the fabrication of mandibular implant-supported fixed detachable prostheses in completely edentulous patients.
The study will include completely edentulous participants rehabilitated with four osseointegrated implants placed in the mandibular arch. Each participant will undergo digital implant impression procedures using three different scanning .
The three scanning techniques being compared are:
- Splinted Scan Bodies: Implant scan bodies will be splinted using composite resin before intraoral scanning.
- Horizontal Non-Calibrated Scan Bodies (IO Connect): Digital impressions will be obtained using the IO Connect horizontal scan body system.
- Auxiliary Geometric Devices: Digital impressions will be acquired using 3D-printed auxiliary geometric devices attached to the scan bodies to provide additional geometric reference landmarks during scanning.
Digital datasets generated from each scanning technique will be analyzed and compared. Verification jigs will be fabricated using CAD/CAM technology and clinically evaluated.
The primary outcomes of the study are scanning accuracy, assessed by measuring linear deviation (µm) and angular deviation (degrees) between implant positions obtained from the different scanning techniques, and three-dimensional surface deviation analysis, assessed through root mean square (RMS) values and median surface deviation obtained from STL file superimposition.
The secondary outcome is passive fit , which will be evaluated using the Sheffield one-screw test and intraoral periapical radiographic assessment.
The findings of this study will help identify the scanning technique that provides the highest accuracy and best passive fit for mandibular implant-supported fixed detachable prostheses and may contribute to improving digital workflows in complete-arch implant rehabilitation.
Undersøgelsestype
Tilmelding (Anslået)
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiekontakt
- Navn: Mostafa Hamed Mostafa Abd El-Hameed Abd El-Hameed, BDS, MSc
- Telefonnummer: +201090461713
- E-mail: mostafa_hamed@dent.tanta.edu.eg
Studiesteder
-
-
Gharbia Governorate
-
Tanta, Gharbia Governorate, Egypten, 31527
- Rekruttering
- faculty of dentistry, Tanta university
-
Kontakt:
- Mostafa Hamed Mostafa Abd El-Hameed
- Telefonnummer: +201090461713
- E-mail: mostafa_hamed@dent.tanta.edu.eg
-
Ledende efterforsker:
- Mostafa Hamed Mostafa Abd El-Hameed, BDS, MSc
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
- Voksen
Tager imod sunde frivillige
Beskrivelse
Inclusion Criteria:
- Completely edentulous patients with age between 40-60 years.
- Adequate bone height to fulfill the criteria for implant placement.
- Patients should have a class I Angle's classification.
Exclusion Criteria:
1-. Insufficient vertical inter-arch space to accommodate the restorative components.
2. Presence of psychiatric or neurological conditions. 3. Any systemic diseases that may affect implant bone osteointegration.
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Enhedens gennemførlighed
- Tildeling: Randomiseret
- Interventionel model: Crossover opgave
- Maskning: Ingen (Åben etiket)
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Eksperimentel: Splinted Scan Bodies with composite
Participants will undergo full-arch digital implant scanning using implant scan bodies splinted with composite resin.
The splinting procedure is intended to improve the stability of scan bodies and reduce positional discrepancies during digital impression acquisition.
|
A full-arch digital implant impression will be obtained using implant scan bodies splinted with composite resin prior to scanning.
The splinting procedure will provide enhanced scan body stability and will be used to minimize positional discrepancies during digital impression acquisition.
|
|
Eksperimentel: horizontal non-calibrated scan bodies
Participants will undergo full-arch digital implant scanning using horizontal non-calibrated scan bodies (IO Connect).
This technique utilizes a horizontal scan body design to facilitate implant position recognition, digital alignment, and complete-arch digital impression acquisition.
|
A full-arch digital implant impression will be obtained using horizontal non-calibrated scan bodies (IO Connect).
The horizontal scan body design will facilitate implant position recognition, digital alignment, and accurate transfer of implant coordinates throughout the digital impression procedure.
|
|
Eksperimentel: Auxiliary Geometric Device Scanning
Participants will undergo full-arch digital implant scanning using 3D-printed auxiliary geometric devices attached to implant scan bodies.
The auxiliary devices provide additional geometric reference landmarks intended to improve scanning accuracy and reduce stitching errors during complete-arch digital impressions.
|
A full-arch digital implant impression will be obtained using 3D-printed auxiliary geometric devices attached to implant scan bodies.
These auxiliary devices will provide additional geometric reference landmarks to improve stitching accuracy, reduce cumulative scanning errors, and enhance complete-arch digital impression accuracy.
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Implant linear and angular deviation
Tidsramme: Immediately after completion of digital scanning day 0
|
The linear and angular deviations of implants will be compared and analyzed across different scanning techniques against each other
|
Immediately after completion of digital scanning day 0
|
|
Three-Dimensional part comparison
Tidsramme: Immediately after completion of digital scanning day 0
|
Three-dimensional surface deviation will be evaluated by uploading all STL files to dedicated comparison software.
Digital superimposition will be performed to calculate the median surface deviation and root mean square (RMS) values between the datasets, providing a quantitative assessment of surface discrepancies among the three scanning techniques.
|
Immediately after completion of digital scanning day 0
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
fit of verification jig
Tidsramme: Within 1 hour of fabrication and intraoral placement of the verification jig
|
Passive fit will be evaluated clinically using the Sheffield one-screw test and confirmed by intraoral periapical radiographs.
|
Within 1 hour of fabrication and intraoral placement of the verification jig
|
Samarbejdspartnere og efterforskere
Sponsor
Efterforskere
- Ledende efterforsker: Mostafa Hamed Mostafa Abd El-Hameed Abd El-Hameed, BDS, MSc, Faculty of Dentistry, Tanta University, Egypt
Datoer for undersøgelser
Studer store datoer
Studiestart (Anslået)
Primær færdiggørelse (Anslået)
Studieafslutning (Anslået)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Andre undersøgelses-id-numre
- RP-11-25-3482
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .