Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Effect of Scanning Techniques on Accuracy of Mandibular Fixed Detachable Prostheses

28. července 2026 aktualizováno: Mostafa Hamed Mostafa Abd El-Hameed, Tanta University

Influence of Three Different Scanning Techniques on Scanning Accuracy for Mandibular Fixed Detachable Prosthesis (A Cross Over Study).

This crossover clinical study aims to evaluate the influence of three different intraoral scanning techniques on the scanning accuracy and passive fit of mandibular implant-supported fixed detachable prostheses in completely edentulous patients. Each participant will undergo digital implant scanning using three methods: splinted scan bodies, horizontal non-calibrated scan bodies (IO Connect), and auxiliary geometric devices.

Přehled studie

Detailní popis

This prospective crossover clinical trial is designed to evaluate and compare the accuracy and passive fit of three different intraoral scanning techniques used for the fabrication of mandibular implant-supported fixed detachable prostheses in completely edentulous patients.

The study will include completely edentulous participants rehabilitated with four osseointegrated implants placed in the mandibular arch. Each participant will undergo digital implant impression procedures using three different scanning .

The three scanning techniques being compared are:

  1. Splinted Scan Bodies: Implant scan bodies will be splinted using composite resin before intraoral scanning.
  2. Horizontal Non-Calibrated Scan Bodies (IO Connect): Digital impressions will be obtained using the IO Connect horizontal scan body system.
  3. Auxiliary Geometric Devices: Digital impressions will be acquired using 3D-printed auxiliary geometric devices attached to the scan bodies to provide additional geometric reference landmarks during scanning.

Digital datasets generated from each scanning technique will be analyzed and compared. Verification jigs will be fabricated using CAD/CAM technology and clinically evaluated.

The primary outcomes of the study are scanning accuracy, assessed by measuring linear deviation (µm) and angular deviation (degrees) between implant positions obtained from the different scanning techniques, and three-dimensional surface deviation analysis, assessed through root mean square (RMS) values and median surface deviation obtained from STL file superimposition.

The secondary outcome is passive fit , which will be evaluated using the Sheffield one-screw test and intraoral periapical radiographic assessment.

The findings of this study will help identify the scanning technique that provides the highest accuracy and best passive fit for mandibular implant-supported fixed detachable prostheses and may contribute to improving digital workflows in complete-arch implant rehabilitation.

Typ studie

Intervenční

Zápis (Odhadovaný)

7

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní kontakt

Studijní místa

    • Gharbia Governorate
      • Tanta, Gharbia Governorate, Egypt, 31527
        • Nábor
        • faculty of dentistry, Tanta university
        • Kontakt:
        • Vrchní vyšetřovatel:
          • Mostafa Hamed Mostafa Abd El-Hameed, BDS, MSc

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dospělý

Přijímá zdravé dobrovolníky

Ano

Popis

Inclusion Criteria:

  1. Completely edentulous patients with age between 40-60 years.
  2. Adequate bone height to fulfill the criteria for implant placement.
  3. Patients should have a class I Angle's classification.

Exclusion Criteria:

1-. Insufficient vertical inter-arch space to accommodate the restorative components.

2. Presence of psychiatric or neurological conditions. 3. Any systemic diseases that may affect implant bone osteointegration.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Proveditelnost zařízení
  • Přidělení: Randomizované
  • Intervenční model: Crossover Assignment
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: Splinted Scan Bodies with composite
Participants will undergo full-arch digital implant scanning using implant scan bodies splinted with composite resin. The splinting procedure is intended to improve the stability of scan bodies and reduce positional discrepancies during digital impression acquisition.
A full-arch digital implant impression will be obtained using implant scan bodies splinted with composite resin prior to scanning. The splinting procedure will provide enhanced scan body stability and will be used to minimize positional discrepancies during digital impression acquisition.
Experimentální: horizontal non-calibrated scan bodies
Participants will undergo full-arch digital implant scanning using horizontal non-calibrated scan bodies (IO Connect). This technique utilizes a horizontal scan body design to facilitate implant position recognition, digital alignment, and complete-arch digital impression acquisition.
A full-arch digital implant impression will be obtained using horizontal non-calibrated scan bodies (IO Connect). The horizontal scan body design will facilitate implant position recognition, digital alignment, and accurate transfer of implant coordinates throughout the digital impression procedure.
Experimentální: Auxiliary Geometric Device Scanning
Participants will undergo full-arch digital implant scanning using 3D-printed auxiliary geometric devices attached to implant scan bodies. The auxiliary devices provide additional geometric reference landmarks intended to improve scanning accuracy and reduce stitching errors during complete-arch digital impressions.
A full-arch digital implant impression will be obtained using 3D-printed auxiliary geometric devices attached to implant scan bodies. These auxiliary devices will provide additional geometric reference landmarks to improve stitching accuracy, reduce cumulative scanning errors, and enhance complete-arch digital impression accuracy.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Implant linear and angular deviation
Časové okno: Immediately after completion of digital scanning day 0
The linear and angular deviations of implants will be compared and analyzed across different scanning techniques against each other
Immediately after completion of digital scanning day 0
Three-Dimensional part comparison
Časové okno: Immediately after completion of digital scanning day 0
Three-dimensional surface deviation will be evaluated by uploading all STL files to dedicated comparison software. Digital superimposition will be performed to calculate the median surface deviation and root mean square (RMS) values between the datasets, providing a quantitative assessment of surface discrepancies among the three scanning techniques.
Immediately after completion of digital scanning day 0

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
fit of verification jig
Časové okno: Within 1 hour of fabrication and intraoral placement of the verification jig
Passive fit will be evaluated clinically using the Sheffield one-screw test and confirmed by intraoral periapical radiographs.
Within 1 hour of fabrication and intraoral placement of the verification jig

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Vrchní vyšetřovatel: Mostafa Hamed Mostafa Abd El-Hameed Abd El-Hameed, BDS, MSc, Faculty of Dentistry, Tanta University, Egypt

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Odhadovaný)

8. srpna 2026

Primární dokončení (Odhadovaný)

1. dubna 2027

Dokončení studie (Odhadovaný)

1. července 2027

Termíny zápisu do studia

První předloženo

28. července 2026

První předloženo, které splnilo kritéria kontroly kvality

28. července 2026

První zveřejněno (Aktuální)

31. července 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

31. července 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

28. července 2026

Naposledy ověřeno

1. července 2026

Více informací

Termíny související s touto studií

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NE

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit