Effect of Scanning Techniques on Accuracy of Mandibular Fixed Detachable Prostheses
Influence of Three Different Scanning Techniques on Scanning Accuracy for Mandibular Fixed Detachable Prosthesis (A Cross Over Study).
Visão geral do estudo
Status
Condições
Descrição detalhada
This prospective crossover clinical trial is designed to evaluate and compare the accuracy and passive fit of three different intraoral scanning techniques used for the fabrication of mandibular implant-supported fixed detachable prostheses in completely edentulous patients.
The study will include completely edentulous participants rehabilitated with four osseointegrated implants placed in the mandibular arch. Each participant will undergo digital implant impression procedures using three different scanning .
The three scanning techniques being compared are:
- Splinted Scan Bodies: Implant scan bodies will be splinted using composite resin before intraoral scanning.
- Horizontal Non-Calibrated Scan Bodies (IO Connect): Digital impressions will be obtained using the IO Connect horizontal scan body system.
- Auxiliary Geometric Devices: Digital impressions will be acquired using 3D-printed auxiliary geometric devices attached to the scan bodies to provide additional geometric reference landmarks during scanning.
Digital datasets generated from each scanning technique will be analyzed and compared. Verification jigs will be fabricated using CAD/CAM technology and clinically evaluated.
The primary outcomes of the study are scanning accuracy, assessed by measuring linear deviation (µm) and angular deviation (degrees) between implant positions obtained from the different scanning techniques, and three-dimensional surface deviation analysis, assessed through root mean square (RMS) values and median surface deviation obtained from STL file superimposition.
The secondary outcome is passive fit , which will be evaluated using the Sheffield one-screw test and intraoral periapical radiographic assessment.
The findings of this study will help identify the scanning technique that provides the highest accuracy and best passive fit for mandibular implant-supported fixed detachable prostheses and may contribute to improving digital workflows in complete-arch implant rehabilitation.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
- Nome: Mostafa Hamed Mostafa Abd El-Hameed Abd El-Hameed, BDS, MSc
- Número de telefone: +201090461713
- E-mail: mostafa_hamed@dent.tanta.edu.eg
Locais de estudo
-
-
Gharbia Governorate
-
Tanta, Gharbia Governorate, Egito, 31527
- Recrutamento
- faculty of dentistry, Tanta university
-
Contato:
- Mostafa Hamed Mostafa Abd El-Hameed
- Número de telefone: +201090461713
- E-mail: mostafa_hamed@dent.tanta.edu.eg
-
Investigador principal:
- Mostafa Hamed Mostafa Abd El-Hameed, BDS, MSc
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
- Completely edentulous patients with age between 40-60 years.
- Adequate bone height to fulfill the criteria for implant placement.
- Patients should have a class I Angle's classification.
Exclusion Criteria:
1-. Insufficient vertical inter-arch space to accommodate the restorative components.
2. Presence of psychiatric or neurological conditions. 3. Any systemic diseases that may affect implant bone osteointegration.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Viabilidade do dispositivo
- Alocação: Randomizado
- Modelo Intervencional: Atribuição cruzada
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Splinted Scan Bodies with composite
Participants will undergo full-arch digital implant scanning using implant scan bodies splinted with composite resin.
The splinting procedure is intended to improve the stability of scan bodies and reduce positional discrepancies during digital impression acquisition.
|
A full-arch digital implant impression will be obtained using implant scan bodies splinted with composite resin prior to scanning.
The splinting procedure will provide enhanced scan body stability and will be used to minimize positional discrepancies during digital impression acquisition.
|
|
Experimental: horizontal non-calibrated scan bodies
Participants will undergo full-arch digital implant scanning using horizontal non-calibrated scan bodies (IO Connect).
This technique utilizes a horizontal scan body design to facilitate implant position recognition, digital alignment, and complete-arch digital impression acquisition.
|
A full-arch digital implant impression will be obtained using horizontal non-calibrated scan bodies (IO Connect).
The horizontal scan body design will facilitate implant position recognition, digital alignment, and accurate transfer of implant coordinates throughout the digital impression procedure.
|
|
Experimental: Auxiliary Geometric Device Scanning
Participants will undergo full-arch digital implant scanning using 3D-printed auxiliary geometric devices attached to implant scan bodies.
The auxiliary devices provide additional geometric reference landmarks intended to improve scanning accuracy and reduce stitching errors during complete-arch digital impressions.
|
A full-arch digital implant impression will be obtained using 3D-printed auxiliary geometric devices attached to implant scan bodies.
These auxiliary devices will provide additional geometric reference landmarks to improve stitching accuracy, reduce cumulative scanning errors, and enhance complete-arch digital impression accuracy.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Implant linear and angular deviation
Prazo: Immediately after completion of digital scanning day 0
|
The linear and angular deviations of implants will be compared and analyzed across different scanning techniques against each other
|
Immediately after completion of digital scanning day 0
|
|
Three-Dimensional part comparison
Prazo: Immediately after completion of digital scanning day 0
|
Three-dimensional surface deviation will be evaluated by uploading all STL files to dedicated comparison software.
Digital superimposition will be performed to calculate the median surface deviation and root mean square (RMS) values between the datasets, providing a quantitative assessment of surface discrepancies among the three scanning techniques.
|
Immediately after completion of digital scanning day 0
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
fit of verification jig
Prazo: Within 1 hour of fabrication and intraoral placement of the verification jig
|
Passive fit will be evaluated clinically using the Sheffield one-screw test and confirmed by intraoral periapical radiographs.
|
Within 1 hour of fabrication and intraoral placement of the verification jig
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Mostafa Hamed Mostafa Abd El-Hameed Abd El-Hameed, BDS, MSc, Faculty of Dentistry, Tanta University, Egypt
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- RP-11-25-3482
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .