Clinical Assessment of a Customized Free-form Progressive Addition Lens Spectacle (CZV_PAL1)
17 april 2017 bijgewerkt door: Meng C. Lin, University of California, Berkeley
The purpose of this study was to compare objective clinical measures of visual performance and subjective measures of satisfaction and preference between standard progressive addition lens (PAL) spectacles and a new type of free-form surfaced, optically customized PAL spectacle.
Studie Overzicht
Toestand
Voltooid
Conditie
Gedetailleerde beschrijving
In a double-masked crossover trial, 95 experienced wearers wore customized free-form PAL spectacles (Test) and standard non-free-form PAL spectacles (Control) for one week each.
All subjects wore both Test and Control spectacles, and the pair to be worn first was randomly assigned.
At dispensing and after 1 week of wear, subjects were tested for distance and near visual acuity (VA) under both high and low contrast; in addition, 30 degree off-axis VA was measured using a novel apparatus, as was the horizontal extent of undistorted vision at reading distance.
Subjects also completed a set of questionnaires detailing their satisfaction levels, adaptation times, and preferences for Test or Control spectacles for different visual tasks.
Studietype
Ingrijpend
Inschrijving (Werkelijk)
95
Fase
- Niet toepasbaar
Contacten en locaties
In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.
Studie Locaties
-
-
California
-
Berkeley, California, Verenigde Staten, 94720-2020
- Clinical Research Center, School of Optometry, University of California, Berkeley
-
-
Deelname Criteria
Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
39 jaar tot 80 jaar (Volwassen, Oudere volwassene)
Accepteert gezonde vrijwilligers
Ja
Geslachten die in aanmerking komen voor studie
Allemaal
Beschrijving
Inclusion Criteria:
- Presbyope
- Experienced PAL spectacle wearer
- Correctable to at least 20/25 in both eyes
- Able and willing to use Test and Control spectacles for 1 week each as primary form of presbyopia correction
- Able and willing to complete all laboratory measurements and questionnaire batteries
Exclusion Criteria:
- Purchasing free-form PAL spectacles from the UC Berkeley Eyewear Center
- Having eye conditions or diseases that could potentially cause a decrease in visual acuity over the course of participation in the study
- Having eye conditions or diseases that could potentially interfere with ability to use Test and Control spectacles as primary form of presbyopia correction
Studie plan
Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Crossover-opdracht
- Masker: Dubbele
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Actieve vergelijker: Randomized Order of Interventions 1
Randomized to first wear standard, non-free-form, non-customized PAL spectacles, then second, crossover to wear individually customized free-form surfaced PAL spectacles
|
Control spectacles include several different PAL brands as selected by patients in the UC Berkeley Optometry Clinic and purchased in the Eyewear Center; after successful fitting and purchase, potential subjects were recruited for the trial.
Test spectacles are Zeiss Individual, free-form surfaced, and customized using the iTerminal device to account for individual back vertex distance, wrap angle and pantoscopic tilt
Andere namen:
|
|
Actieve vergelijker: Randomized Order of Interventions 2
Randomized to first wear individually customized free-form surfaced PAL spectacles, then second, crossover to wear standard, non-free-form, non-customized PAL spectacles
|
Control spectacles include several different PAL brands as selected by patients in the UC Berkeley Optometry Clinic and purchased in the Eyewear Center; after successful fitting and purchase, potential subjects were recruited for the trial.
Test spectacles are Zeiss Individual, free-form surfaced, and customized using the iTerminal device to account for individual back vertex distance, wrap angle and pantoscopic tilt
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Visual Acuity, High Contrast, Distance Chart
Tijdsspanne: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
Standard assessment of high contrast visual acuity at distance, as in normal clinical practice, using Baily-Lovey charts and the M&S Technologies Smart System II visual acuity projection system.
|
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
|
Visual Acuity, Low Contrast, Distance Chart
Tijdsspanne: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
Standard assessment of low contrast visual acuity at distance, as in normal clinical practice, using Baily-Lovey charts and the M&S Technologies Smart System II visual acuity projection system.
|
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
|
Visual Acuity, High Contrast, Near Chart
Tijdsspanne: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
Standard assessment of high contrast visual acuity at near, as in normal clinical practice, using Baily-Lovey charts and the M&S Technologies Smart System II visual acuity projection system.
|
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
|
Visual Acuity, Low Contrast, Near Chart
Tijdsspanne: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
Standard assessment of low contrast visual acuity at near, as in normal clinical practice, using Baily-Lovey charts and the M&S Technologies Smart System II visual acuity projection system.
|
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
|
30-degree Off-axis Distance Visual Acuity, High Contrast Chart
Tijdsspanne: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
Measured with subject immobilized in specially designed apparatus, keeping head pointed straight forward and moving only the eyes to left or right to view the off-axis chart
|
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
|
30-degree Off-axis Distance Visual Acuity, Low Contrast Chart
Tijdsspanne: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
Measured with subject immobilized in specially designed apparatus, keeping head pointed straight forward and moving only the eyes to left or right to view the off-axis chart
|
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
|
Horizontal Extent of Undistorted Vision at Reading Distance
Tijdsspanne: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
Novel apparatus designed to immobilize head and allow subject to indicate point of peripheral optical distortion on a modified Amsler-type grid
|
Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
|
|
Questionnaire Battery
Tijdsspanne: At study exit, after both Test and Control spectacles had been worn for 1 week each
|
Forced-choice Likert scale preference questionnaire
|
At study exit, after both Test and Control spectacles had been worn for 1 week each
|
Medewerkers en onderzoekers
Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.
Medewerkers
Onderzoekers
- Hoofdonderzoeker: Meng C. Lin, OD, PhD, Clinical Research Center, School of Optometry, University of California, Berkeley
Publicaties en nuttige links
De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.
Studie record data
Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.
Bestudeer belangrijke data
Studie start
1 februari 2009
Primaire voltooiing (Werkelijk)
1 oktober 2009
Studie voltooiing (Werkelijk)
1 oktober 2009
Studieregistratiedata
Eerst ingediend
3 november 2010
Eerst ingediend dat voldeed aan de QC-criteria
3 november 2010
Eerst geplaatst (Schatting)
4 november 2010
Updates van studierecords
Laatste update geplaatst (Werkelijk)
18 april 2017
Laatste update ingediend die voldeed aan QC-criteria
17 april 2017
Laatst geverifieerd
1 april 2017
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- CZV_PAL1
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .