- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT01441219
Evaluation the Performance of Given Diagnostic System in Detection of Bleeding Events in the Small Bowel
Evaluation the Performance of Given Diagnostic System in Detection of Bleeding Events in the Small Bowel: a Single-arm Prospective Cohort Study.
Obscure gastrointestinal bleeding (OGIB) has been one of the most challenging area in the field of gastroenterology, as small bowel is beyond the reach of ordinary endoscopes like oesophagogastroduodenoscopy (OGD) and colonoscopy. Thanks for the latest technological advancement for investigating small intestine, we are now capable of obtaining intraluminal images safely through capsule endoscopy (CE). Its role in obscure gastrointestinal bleeding, Crohn's disease and other small bowel pathologies has already been proven, and nowadays it is suggested by various authorities to be the first-line modality among all small bowel investigations.
The investigators group has showed that CE can alter the clinical management of patients with OGIB - patients with negative CE has lower rebleeding rate, and therefore we may adopt a conservative approach for them. Although supported by some other group as well, conflicting results were still reported in the literature about the out-come of these patients. The main criticisms for these studies are that, CE can only identify 61% of the underlying small bowel bleeding pathology, and one can never ascertain the outcome of patients with negative CE examination. Apparently there is still room for improvement in the current CE technology.
Studie Overzicht
Gedetailleerde beschrijving
Newer generation of CE (PillCam ColonTM) has been developed to investigate the large bowel. It is different from small bowel CE that it consists of two cameras at both ends of the capsule, so as to enhance the coverage of colonic mucosa visualization. An improved generation of this colon capsule, named PillCam Colon 2TM, is also in its developmental phase. With the new "adaptive frame rate" (AFR) technology, the CE optimizes the visual coverage of the bowel by increasing the frame rate up to 35 frames per second when the capsule is moving quickly in certain areas, while decreasing the frame rate down to 4 frames per second when the capsule is moving slowly or remains stationary so as to conserve the battery life. Preliminary data from colorectal cancer screening has shown that it could improve the diagnostic yield of colonic polyps.
The investigators hypothesize that, by re-programming the PillCam Colon 2TM so as to initiate AFR since ingestion, it could improve the visualization of small intestinal lumen and hence improves the sensitivity of small bowel CE examination.
Studietype
Inschrijving (Werkelijk)
Fase
- Fase 2
- Fase 3
Contacten en locaties
Studie Locaties
-
-
-
Hong Kong, China
- Prince of Wales Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Patients with overt GI bleeding (hematemesis, coffee-grounds, rectal bleeding and/or melena) with negative OGD but not critically ill, who should read positive on small bowel investigation (SBI)
- Patients with occult GI bleeding (Faecal occult blood test,FOBT +)
- Patients with suspected arteriovenous(AV) malformations.
- Patients treated with nonsteroidal antiinflammatory drugs (NSAIDs)
- Patients with active Crohn's disease(CD), with no evidence of obstruction
Exclusion Criteria:
- In patients with known or suspected gastrointestinal obstruction, strictures, or fistulas based on the clinical picture or pre-ingestion testing and profile.
- In patients with cardiac pacemakers or other implanted electromedical devices.
- In patients with dysphagia or other swallowing disorders.
- Unable to obtain informed written consent
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Diagnostisch
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Colon 2
using Colon 2 capsule in detecting bleeding events in small bowel
|
Ingest one colon 2 capsule
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Diagnostic yield for bleeding events in the small bowel
Tijdsspanne: 1 year
|
Review the capsule video to detect the bleeding events.
|
1 year
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Joseph JY Sung, MD, CUHK
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- C2 in SB
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .