Impact of Different Modes of Noninvasive Ventilation on Regional Oximetry and Hemodynamics in Premature Newborn
Impact of Different Modes of Noninvasive Ventilation (NCPAP Versus TrPA) on Regional Cerebral and Splanchnic Oximetry as Measured by Near Infrared Spectroscopy (NIRS) and Hemodynamics Using Echocardiography in Premature Newborns
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
Preterm babies under 32 weeks of gestational age usually needs to be supported with breathing machine because of different kinds of problems like lungs immaturity or infection. One type of breathing machine support is called CPAP(Continuous Positive Airway Pressure).This breathing support machine is connected to the nose to help preterm baby breathe. This machine blows air or an air/oxygen mixture through the nose and in to the baby's lung; this helps to keep baby's lungs fully open and makes it easier for the baby to breathe. There are two ways this machine can help the baby breathe - it can either blow the air/oxygen mixture at the same pressure all the time…we call that CPAP, or we can vary the pressure - we call that TrPA(Trigger Pressure Assist). Both methods have been in use in neonatal intensive care units(NICUs) for several years and both methods help with the breathing of babies.
The breathing machine (CPAP) makes the lungs better inflated. This inflation might affect the ability of the heart to push the blood to the organs through the blood vessels. Also we do not know whether there is any difference in the blood flow or oxygen delivery depending whether the baby is on CPAP or TrPA.
We will measure the heart function using Ultrasound (Echocardiography). To measure the efficiency of the flow of the blood through the vessels to the organs we will use Near Infra Red Spectroscopy (NIRS); this involves applying a sensor to the baby's skin - one on the forehead and one on the tummy and connecting the sensors to a machine which can measure the oxygen level in the organ under the skin.
While the baby is on CPAP, we will start monitoring oxygen saturation by applying NIRS sensors to the forehead and the abdomen. After 3 hours we will do echocardiography (ultrasound of the heart)to see any changes that might happen to the heart and blood vessels while the baby is on CPAP. Then, using the same machine, we will change the mode of respiratory support to TrPA. After another three hours, we will do another echocardiography (ultrasound of the heart), then we will stop NIRS monitoring and change the mode of respiratory support back to CPAP.
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
Manitoba
-
Winnipeg, Manitoba, Canada, R2H 2A6
- St. Boniface General Hospital
-
Winnipeg, Manitoba, Canada, R3A 1S1
- Health Sciences Center
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- Preterm infants less than 34 weeks gestational age
- Requirement of CPAP or TrPA as a mode of respiratory support
Exclusion Criteria:
- Lack of parental consent
- Preterm infants more than 34 gestational weeks
- Preterm infants with congenital malformation
- Severe perinatal asphyxia
- Hemodynamically significant patent ductus arteriosus (PDA)
- Pulmonary hypertension
- Septic shock
- Any associated congenital heart diseases other than non-significant PDA or patent foramen ovale (PFO)
- Stage 2 or 3 necrotising enterocolitis (NEC)
- Intraventricular hemorrhage (IVH) grade 3 or 4
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
Preterm ≤ 32 weeks GA, on CPAP
Preterm infants less than 32 weeks gestational age requiring CPAP as a mode of respiratory support and admitted in the NICU.While the baby is on CPAP,tissue oxygen saturation monitoring will be started by applying NIRS(Near Infrared Spectroscopy Monitoring) sensors to the forehead and the abdomen.
After 3 hours,echocardiography(including Superior Mesenteric Artery Doppler) will be done while the baby is on CPAP.
Then, using the same machine, the mode of respiratory support will be changed to TrPA.
After another three hours,another echocardiography will be done,then NIRS monitoring will be stopped and the mode of respiratory support will be changed back to CPAP.
|
Measurement of:
Measurement of cerebral and mesenteric regional oxygen saturation(rSO2) trends and data while the baby on CPAP or TrPA modes of noninvasive ventilation.
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Change in cardiac output
Tijdsspanne: Day 3 of life till 2 months of age
|
Targeted neonatal Echocardiography will be done according to the guidelines accepted by the writing group of the American society of echocardiography in collaboration with associations of European pediatric cardiologists The following standard windows will be used:
Measurements:
|
Day 3 of life till 2 months of age
|
|
Changes in Superior Mesenteric Artery and Middle Cerebral Artery Doppler flow.
Tijdsspanne: Day 3 of life till 2 months of age
|
Day 3 of life till 2 months of age
|
|
|
Cerebral and mesenteric regional tissue oxygenation
Tijdsspanne: Day 3 of life till 2 months of age
|
Cerebral and mesenteric rSO2 trends and data (obtained by NIRS) will be recorded along with simultaneous pulse oximeter trends and data.
The splanchnic-cerebral oxygenation ratio (SCOR) reflecting the ratio between regional cerebral oxygen saturation(rcSO2) and regional splanchnic oxygen saturation (rsSO2)(rcSO2/rsSO2) will be analyzed.
|
Day 3 of life till 2 months of age
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Studie directeur: Ganesh Srinivasan, MD, University of Manitoba
- Studie directeur: Mary S Seshia, MD, University of Manitoba
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- B2013: 055
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .