- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07795541
OPTImizing Lead Placement in Patients Requiring Pacemaker After Cardiac Surgery (OPTI-PACS)
OPTIMIZING LEAD PLACEMENT IN PATIENTS REQUIRING PACEMAKER AFTER CARDIAC SURGERY
Conventional right ventricular pacing has been associated with ventricular dyssynchrony and an increased risk of pacing-induced cardiomyopathy, which may lead to worse clinical outcomes. To lessen the burden of pacing-induced cardiomyopathy, the adoption of conduction system pacing has increased in recent years. In patients with normal cardiac function, measured as left ventricular ejection fraction, the superiority of conduction system pacing is less clear. As a result, both pacing strategies remain in widespread clinical use.
Patients undergoing cardiac surgery represent a vulnerable cohort for pacing-induced cardiomyopathy, given their established structural heart disease, and postoperative atrioventricular block remains a common occurrence in these patients.
This multicenter randomized trial aims to evaluate the use of conduction system pacing, in the form of left bundle branch area pacing, versus conventional pacing in patients with normal left ventricular ejection fraction after cardiac surgery.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
A high percentage of ventricular pacing increases the risk of pacing-induced cardiomyopathy. Pacing-induced cardiomyopathy is a syndrome defined by left ventricular dysfunction secondary to chronic right ventricular pacing, resulting in impaired outcomes. Pacing-induced cardiomyopathy is estimated to affect approximately 10-20% of patients with a high proportion of right ventricular pacing (>20%), a population that mainly consists of patients with atrioventricular block (AVB). The abnormal activation leads to prolonged electrical and mechanical activation, which results in ventricular dyssynchrony. Other important risk factors for pacing-induced cardiomyopathy include structural heart disease and reduced ejection fraction, male sex and wide, paced QRS.
Clinical practice guidelines support pacemaker implantation following cardiac surgery only for severe and non-transient bradyarrhythmias, as pacemaker implantation increases the risk of severe infections and device-related long-term complications. Evidence suggests that a substantial proportion of patients who receive a pacemaker following cardiac surgery have limited need for pacing at long-term follow-up. Thus, the risk/benefit ratio for patients following cardiac surgery differs from that of the general population, while these patients also form a vulnerable population at high risk for pacing-induced cardiomyopathy.
Over the last decade, a conduction system pacing strategy called left bundle branch area pacing (LBBAP) has been developed. In LBBAP, the pacemaker lead is inserted deep into the interventricular septum from the right ventricle to the left ventricular endocardium, targeting the left bundle and its resulting fascicles. As the current understanding of the development of pacing-induced cardiomyopathy suggests that the electrical dyssynchrony introduced by right ventricular pacing plays a crucial role, our hypothesis is that its incidence could be reduced by the favorable electrical activation achieved with LBBAP.
There are ongoing randomized controlled trials of conduction system pacing in the general population; however, none are investigating cardiac surgery patients. These patients differ substantially from the general population in age, expected long-term survival, and cardiovascular health. This increases their risk of pacing-induced cardiomyopathy and could influence the feasibility of conduction system pacing due to their otherwise impaired cardiovascular health. At the same time, their long-term pacing dependence could differ from that of the general population.
Therefore, the aim of the present multicenter randomized controlled trial is to evaluate the long-term outcomes of LBBAP versus right ventricular pacing after cardiac surgery in patients with normal left ventricular ejection fraction. A secondary aim is to assess the feasibility of LBBAP after cardiac surgery with regard to implantation success and long-term electrical parameters. The results of this trial are anticipated to provide clinically meaningful evidence to guide pacing strategy selection in this patient cohort.
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studiecontact
- Naam: Andreas S Martinsson, MD, PhD
- Telefoonnummer: +46313427717
- E-mail: andreas.s.martinsson@vgregion.se
Studie Contact Back-up
- Naam: Alice David, MD
- Telefoonnummer: +313429684
- E-mail: laura.david@vgregion.se
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Beschrijving
Inclusion Criteria:
- High degree atrioventricular block
- Cardiac surgery within 30 days of pacemaker implantation
- Written informed consent
- Current left ventricular ejection fraction at or above 50%
Exclusion Criteria:
- Any concomitant condition that results in a life expectancy of less than 1 year
- Planned for heart transplant or left ventricular assist device
- Current dialysis
- Not suitable according to the opinion of the investigators due to characteristics that interfere with the adherence to the study protocol.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Dubbele
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Actieve vergelijker: Conventional pacing strategy
This arm will receive a conventional pacemaker lead if they have atrioventricular block after cardiac surgery
|
Conventional pacing strategy
|
|
Experimenteel: Left bundle branch area pacing strategy
This arm will receive a left bundle branch area pacing pacemaker lead if they have atrioventricular block after cardiac surgery
|
Conventional pacing strategy versus conduction system pacing strategy in the form of left bundle branch area pacing
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Change in left ventricular ejection fraction
Tijdsspanne: 1 year
|
Change in left ventricular ejection fraction between enrollment and end of follow-up
|
1 year
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Sterfte door alle oorzaken
Tijdsspanne: 1 jaar
|
Sterfte door alle oorzaken
|
1 jaar
|
|
Change in left ventricular end-diastolic diameter
Tijdsspanne: 1 year
|
Change in LVEDD from enrollment to end of study follow-up
|
1 year
|
|
Clinical endpoints - composite
Tijdsspanne: 1 year
|
Composite of all-cause mortality, heart failure hospitalization, device-related hospitalization
|
1 year
|
|
Heart failure hospitalization
Tijdsspanne: 1 year
|
Heart failure hospitalization
|
1 year
|
|
Device-related hospitalization
Tijdsspanne: 1 year
|
Device-related hospitalization
|
1 year
|
|
Quality-of-life measurement
Tijdsspanne: 1 year
|
Quality-of-life measurement by standardized questionnaire
|
1 year
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Andreas S Martinsson, MD, PhD, Sahlgrensa university hospital
Studie record data
Bestudeer belangrijke data
Studie start (Geschat)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 2025-08652-01
- 2025 (Subsidie/contract van de Amerikaanse NIH: Faculty of Social Sciences Scientific Grant at the University of Gdańsk)
- 20241208 (Ander subsidie-/financieringsnummer: Swedish Heart- Lung Foundation)
- ALFGBG-977905 (Ander subsidie-/financieringsnummer: ALF Agreement (Swedish state))
- ALFGBG-1029431 (Ander subsidie-/financieringsnummer: ALF Agreement (Swedish state))
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .