A Comparison of Two Urinary Catheters of Different Lengths for Female Use, in Intermittent Catheterization
A Multi Centre, Single-blind, Randomized, Cross-over Study Comparing Two Female Catheters With Different Length in Terms of Residual Urine After Intermittent Catheterization
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Szczegółowy opis
The study personnel will conduct three bladder scans after each catheterization in order to obtain the mean residual urine volume. Each patient will catheterize herself two times with each product, i.e. a total of four catheterizations.
Diagnosis and BMI will be collected at visit 1 to assess whether the residual urine volume differs between these subgroups.
The hypothesis that the mean residual volumes were equal when using the 7 and the 10 centimeter catheters was tested by means of the Wilcoxon signed rank test.
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Borås, Szwecja, SE-501 82
- Rehabiliteringskliniken, Södra Älvsborgs Sjukhus
-
Gothenburg, Szwecja, SE-413 45
- Verksamhet Urologi, Sahlgrenska Universitetssjukhuset
-
Lund, Szwecja, SE-221 85
- Clinical Research and Trial Centre, Lund University Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Provision of signed informed consent
- Female subjects aged 18 years and over
- Experienced users of CIC with a minimum of one month of use
- Practice CIC a minimum of 1 time per day
- Practice CIC with female catheters with a maximum length of 20 cm
- Perform self-catheterization
- Sufficient hand function to be able to open and handle catheter packages
- Use catheters with Ch 10, 12 or 14
Exclusion Criteria:
- Pregnancy
- Ongoing symptomatic UTI
- Involvement in the planning and conduct of the study (applies to both Astra Tech staff or staff at the study site)
- Previous enrolment or randomisation of treatment in the present study
- Participation in another clinical study during the study period
- Severe non-compliance to protocol as judged by the investigator and/or Astra Tech
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Inny
- Przydział: Randomizowane
- Model interwencyjny: Zadanie krzyżowe
- Maskowanie: Podwójnie
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: AABB
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 7 cm then 7 cm then 10 cm then 10 cm Four catheterizations in total, two catheterizations with each study product in a randomized order. |
Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.
Inne nazwy:
|
|
Eksperymentalny: ABAB
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 7 cm then 10 cm then 7 cm then 10 cm Four catheterizations in total, two catheterizations with each study product in a randomized order. |
Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.
Inne nazwy:
|
|
Eksperymentalny: ABBA
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 7 cm then 10 cm then 10 cm then 7 cm Four catheterizations in total, two catheterizations with each study product in a randomized order. |
Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.
Inne nazwy:
|
|
Eksperymentalny: BAAB
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 10 cm then 7 cm then 7 cm then 10 cm Four catheterizations in total, two catheterizations with each study product in a randomized order. |
Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.
Inne nazwy:
|
|
Eksperymentalny: BABA
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 10 cm then then 7 cm then 10 cm then 7 cm Four catheterizations in total, two catheterizations with each study product in a randomized order. |
Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.
Inne nazwy:
|
|
Eksperymentalny: BBAA
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 10 cm then 10 cm then 7 cm then 7 cm Four catheterizations in total, two catheterizations with each study product in a randomized order. |
Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.
Inne nazwy:
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Bladder Scan Measurements of Residual Urine Volume
Ramy czasowe: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
Measurements were performed with the bladder scan BVI 3000. The primary outcome variable was average residual urine volume (mL) calculated from repetitive bladder scans performed after each catheterization. Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. |
Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Number of Subjects With a Residual Volume >5mL or ≤5mL
Ramy czasowe: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. At least 2 hours had to pass between 2 catheterizations.
|
Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. At least 2 hours had to pass between 2 catheterizations.
|
|
|
Number of Subjects With a Residual Volume >10mL or ≤10mL
Ramy czasowe: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
|
|
Number of Subjects With a Residual Volume >30mL or ≤30mL
Ramy czasowe: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
|
|
Number of Subjects With a Residual Volume >50mL or ≤50mL
Ramy czasowe: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
|
|
Does the Subject's Bladder Feel Completely Empty After Catheterisation (All Subjects)
Ramy czasowe: Question asked minutes after catheterization.
|
After each catheterization the study nurse will ask the subject whether it feels as if the bladder is completely emptied or not. 0=No and 1=Yes. |
Question asked minutes after catheterization.
|
Współpracownicy i badacze
Sponsor
Śledczy
- Główny śledczy: Ulf Malmqvist, MD, PhD, Assoc.Prof., Clinical Research and Trial Centre, Lund University Hospital
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Inne numery identyfikacyjne badania
- YA-LOF-0015
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
produkt wyprodukowany i wyeksportowany z USA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .