- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT00799981
A Comparison of Two Urinary Catheters of Different Lengths for Female Use, in Intermittent Catheterization
A Multi Centre, Single-blind, Randomized, Cross-over Study Comparing Two Female Catheters With Different Length in Terms of Residual Urine After Intermittent Catheterization
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
The study personnel will conduct three bladder scans after each catheterization in order to obtain the mean residual urine volume. Each patient will catheterize herself two times with each product, i.e. a total of four catheterizations.
Diagnosis and BMI will be collected at visit 1 to assess whether the residual urine volume differs between these subgroups.
The hypothesis that the mean residual volumes were equal when using the 7 and the 10 centimeter catheters was tested by means of the Wilcoxon signed rank test.
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Borås, Suécia, SE-501 82
- Rehabiliteringskliniken, Södra Älvsborgs Sjukhus
-
Gothenburg, Suécia, SE-413 45
- Verksamhet Urologi, Sahlgrenska Universitetssjukhuset
-
Lund, Suécia, SE-221 85
- Clinical Research and Trial Centre, Lund University Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Provision of signed informed consent
- Female subjects aged 18 years and over
- Experienced users of CIC with a minimum of one month of use
- Practice CIC a minimum of 1 time per day
- Practice CIC with female catheters with a maximum length of 20 cm
- Perform self-catheterization
- Sufficient hand function to be able to open and handle catheter packages
- Use catheters with Ch 10, 12 or 14
Exclusion Criteria:
- Pregnancy
- Ongoing symptomatic UTI
- Involvement in the planning and conduct of the study (applies to both Astra Tech staff or staff at the study site)
- Previous enrolment or randomisation of treatment in the present study
- Participation in another clinical study during the study period
- Severe non-compliance to protocol as judged by the investigator and/or Astra Tech
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Outro
- Alocação: Randomizado
- Modelo Intervencional: Atribuição cruzada
- Mascaramento: Dobro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: AABB
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 7 cm then 7 cm then 10 cm then 10 cm Four catheterizations in total, two catheterizations with each study product in a randomized order. |
Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.
Outros nomes:
|
|
Experimental: ABAB
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 7 cm then 10 cm then 7 cm then 10 cm Four catheterizations in total, two catheterizations with each study product in a randomized order. |
Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.
Outros nomes:
|
|
Experimental: ABBA
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 7 cm then 10 cm then 10 cm then 7 cm Four catheterizations in total, two catheterizations with each study product in a randomized order. |
Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.
Outros nomes:
|
|
Experimental: BAAB
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 10 cm then 7 cm then 7 cm then 10 cm Four catheterizations in total, two catheterizations with each study product in a randomized order. |
Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.
Outros nomes:
|
|
Experimental: BABA
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 10 cm then then 7 cm then 10 cm then 7 cm Four catheterizations in total, two catheterizations with each study product in a randomized order. |
Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.
Outros nomes:
|
|
Experimental: BBAA
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 10 cm then 10 cm then 7 cm then 7 cm Four catheterizations in total, two catheterizations with each study product in a randomized order. |
Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Bladder Scan Measurements of Residual Urine Volume
Prazo: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
Measurements were performed with the bladder scan BVI 3000. The primary outcome variable was average residual urine volume (mL) calculated from repetitive bladder scans performed after each catheterization. Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. |
Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Number of Subjects With a Residual Volume >5mL or ≤5mL
Prazo: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. At least 2 hours had to pass between 2 catheterizations.
|
Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. At least 2 hours had to pass between 2 catheterizations.
|
|
|
Number of Subjects With a Residual Volume >10mL or ≤10mL
Prazo: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
|
|
Number of Subjects With a Residual Volume >30mL or ≤30mL
Prazo: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
|
|
Number of Subjects With a Residual Volume >50mL or ≤50mL
Prazo: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
|
|
|
Does the Subject's Bladder Feel Completely Empty After Catheterisation (All Subjects)
Prazo: Question asked minutes after catheterization.
|
After each catheterization the study nurse will ask the subject whether it feels as if the bladder is completely emptied or not. 0=No and 1=Yes. |
Question asked minutes after catheterization.
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Ulf Malmqvist, MD, PhD, Assoc.Prof., Clinical Research and Trial Centre, Lund University Hospital
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Outros números de identificação do estudo
- YA-LOF-0015
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .