Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Total Knee Arthroplasty With Personalized Implantation: Computer Navigation-Assisted Surgery Versus Robotic-Assisted Surgery (CAN-ARD)

5 maja 2026 zaktualizowane przez: Groupe Hospitalier Diaconesses Croix Saint-Simon

Total Knee Replacement With Personalized Implantation Navigation-assisted Surgery Versus Robotic Assistance "CAN-ARD"

Title: Personalized Total Knee Arthroplasty: Computer-Assisted Navigation vs. Robotic Assistance (CAN-ARD).

Summary:

Knee osteoarthritis is frequently treated with Total Knee Arthroplasty (TKA). However, approximately 20% of patients remain dissatisfied following the procedure. This study aims to compare two surgical assistance technologies designed to improve prosthetic placement accuracy: Computer-Assisted Navigation (CAN) and Robotic-Arm Assistance (RA).

The primary objective is to determine if there is a significant difference in functional outcomes and the "forgotten joint" sensation (measured by the Forgotten Joint Score - FJS) between patients operated on with robotic assistance versus those with traditional navigation at 3, 12, and 24 months post-surgery. The study's hypothesis is that there is no major clinical difference between these two techniques when applied within a personalized alignment strategy.

Przegląd badań

Szczegółowy opis

Background and Rationale:

Personalized alignment in total knee arthroplasty combines the restoration of the patient's unique anatomy (restricted kinematic alignment) with joint stability. While computer-assisted navigation has been successfully used since 2003 to plan and control implant positioning, robotic assistance is gaining popularity due to its ability to perform more precise bone cuts using a haptic robotic arm. This study seeks to investigate whether this technical gain in precision translates into a real clinical benefit for the patient in terms of satisfaction and joint perception.

Study Design:

This is an interventional, prospective, randomized, single-center study. A total of 140 patients (70 per group) will be enrolled.

Interventions:

Participants will be randomly assigned to one of the following two arms:

Navigation Group: TKA implantation (Attune® CR) guided by an intraoperative computer navigation system.

Robotic Group: TKA implantation using a robotic-arm-assisted system (a motorized saw linked to the navigation software).

Follow-up and Evaluations:

Patients will be followed for 24 months. Evaluations will include:

Primary Endpoint: Forgotten Joint Score (FJS) at 3, 12, and 24 months.

Secondary Endpoints: Satisfaction and functional scores (KOOS, SKV, Net Promoter Score), range of motion measurements, operative time, and monitoring of any complications.

Target Population:

Adults (≥ 18 years) scheduled for primary total knee arthroplasty for osteoarthritis, with no history of major bone surgery on the affected limb.

Typ studiów

Interwencyjne

Zapisy (Szacowany)

140

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Lokalizacje studiów

    • Paris
      • Paris, Paris, Francja, 75020
        • Rekrutacyjny
        • Groupe Hospitalier Diaconesses Croix Saint Simon

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły
  • Starszy dorosły

Akceptuje zdrowych ochotników

Nie

Opis

Inclusion Criteria:

  • Patient providing written informed consent according to regulatory requirements
  • Male or female patients aged ≥18 years
  • Patients undergoing primary total knee arthroplasty for osteoarthritis
  • Use of Attune® prosthesis with posterior cruciate ligament retention (CR) and patellar resurfacing

Exclusion Criteria:

  • History of ligament reconstruction
  • Previous fracture or bone surgery (osteotomy) of the ipsilateral femur or tibia (except hip or ankle surgery)
  • Preoperative knee stiffness with flexion contracture >15° or flexion <90°
  • Individuals deprived of liberty by judicial or administrative decision
  • Patients not affiliated with a social security system
  • Patients unable to understand French
  • Patients with cognitive impairment
  • Patients whose place of residence makes close clinical follow-up impossible -- Women of childbearing potential without effective contraception
  • Pregnant or breastfeeding women

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Badania usług zdrowotnych
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Eksperymentalny: Robotic
Patients undergoing Prosthetic knee arthroplasty under robotic assistance
Total Knee Arthroplasty (TKA) performed using a robotic-arm-assisted system connected to navigation software. Like the navigation group, this arm utilizes the personalized alignment strategy and the Attune® CR prosthesis. Instead of manual cutting guides, the surgeon manipulates a robotic arm equipped with a motorized saw to perform the bone cuts according to the pre-planned digital model. This technology is intended to increase the precision of bone resections.
Aktywny komparator: Navigation
Patients undergoing Prosthetic knee arthroplasty under navigation assistance
Total Knee Arthroplasty (TKA) performed using an intraoperative computer navigation system. The procedure follows a personalized alignment strategy (restricted kinematic alignment combined with joint stability). After creating a digital model of the knee and mapping anatomical landmarks, the navigation system assists the surgeon in manually positioning the bone cutting guides. The primary implant used is the Attune® CR (Cruciate-Retaining) prosthesis with patellar resurfacing.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Forgotten Joint Score (FJS).
Ramy czasowe: 3, 12, and 24 months postoperatively.
Assessment of the patient's ability to forget the artificial joint in daily life. Minimum score: 0, Maximum score: 100. A higher score indicates a better outcome (the patient is less aware of the prosthetic joint)
3, 12, and 24 months postoperatively.

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Knee Injury and Osteoarthritis Outcome Score (KOOS).
Ramy czasowe: 3, 12, and 24 months postoperatively.
Evaluation of the patient's opinion about their knee and associated problems. Minimum score: 0, Maximum score: 100. A higher score represents a better outcome.
3, 12, and 24 months postoperatively.
Self Knee Value (SKV).
Ramy czasowe: 3, 12, and 24 months postoperatively.
Patient's subjective assessment of their knee as a percentage of a normal knee. Scale: 0% to 100%. A higher percentage represents a better outcome.
3, 12, and 24 months postoperatively.
Net Promoter Score (NPS)
Ramy czasowe: 3, 12, and 24 months postoperatively.
A single-question survey used to measure patient satisfaction and their willingness to recommend the surgical procedure to others. The score is calculated based on responses to a single question on a scale of 0 to 10 (where 0 is "not at all likely" and 10 is "extremely likely"). Respondents are grouped as Promoters (9-10), Passives (7-8), or Detractors (0-6). The final NPS is calculated by subtracting the percentage of Detractors from the percentage of Promoters, resulting in a score ranging from -100 to +100. A higher score indicates higher patient satisfaction
3, 12, and 24 months postoperatively.
Active Range of Motion.
Ramy czasowe: Preoperatively, and at 3 months, 12 months, and 24 months postoperatively.
Measurement of the active flexibility (extension and flexion) of the operated knee using a goniometer. Measured in degrees
Preoperatively, and at 3 months, 12 months, and 24 months postoperatively.
Operative Time
Ramy czasowe: During the surgical procedure (Day 0).
Total duration of the surgical procedure, measured from the initial skin incision to the completion of skin closure.
During the surgical procedure (Day 0).
Incidence of Surgical and Postoperative Adverse Events.
Ramy czasowe: Through 24 months postoperatively.
Documentation of complications including:Intraoperative: Technology-related issues or interruption of surgical assistance. Postoperative: Revision surgery, manipulation under anesthesia, or implant loosening.
Through 24 months postoperatively.

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

26 stycznia 2026

Zakończenie podstawowe (Szacowany)

1 września 2028

Ukończenie studiów (Szacowany)

26 stycznia 2029

Daty rejestracji na studia

Pierwszy przesłany

28 kwietnia 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

5 maja 2026

Pierwszy wysłany (Rzeczywisty)

8 maja 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

8 maja 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

5 maja 2026

Ostatnia weryfikacja

1 maja 2026

Więcej informacji

Terminy związane z tym badaniem

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj