- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07612540
Retention and Caries Prevention of Giomer Sealant With or Without Diode Laser Pre-treatment: A Randomized Controlled Trial
Retention Rate and Caries Prevention of Giomer Based Sealant With and Without Diode Laser Pre-treatment in Young Adults: A Randomized Controlled Trial
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Szczegółowy opis
The protocol investigates whether diode laser pre-treatment can improve the clinical performance of a giomer-based fissure sealant in young adults. The study is designed as a two-arm randomized controlled clinical trial evaluating sealant retention and caries prevention over a 12-month period.
The background emphasizes that pits and fissures of posterior teeth are highly susceptible to caries, and fissure sealants are an evidence-based preventive approach. Giomer sealants combine the advantages of resin composites and glass ionomer materials through S-PRG filler technology, offering fluoride release and simplified application using self-etch primer systems. However, concerns remain regarding their long-term retention. Diode laser enamel pre-treatment is proposed to enhance enamel surface roughness, improve sealant penetration, and increase resistance to acid dissolution, potentially improving retention and caries prevention.
The study aims to compare giomer-based sealant application with and without diode laser pre-treatment in patients aged 17-22 years having deep retentive fissures with ICDAS scores 0-2 in second and third molars. Primary outcome is sealant retention assessed using Simonsen's criteria, while secondary outcome is caries prevention evaluated using modified USPHS criteria at baseline, 6 months, and 12 months.
The null hypothesis states that diode laser pre-treatment will not significantly affect retention rate or caries prevention compared with conventional application. The protocol includes detailed sample size calculation based on previous literature, resulting in 37 teeth per group after adjustment for dropouts. Statistical analysis will include chi-square and Cochran's Q tests with significance set at p ≤ 0.05.
Eligibility criteria include healthy young adults with good oral hygiene and absence of parafunctional habits. Teeth with fractures, existing restorations, secondary caries, developmental defects, or periodontal compromise are excluded.
Methodologically, participants are randomly allocated using opaque sealed envelopes. In the control group, self-etch primer is applied before placement of BeautiSealant. In the laser group, a 940-nm diode laser is first applied to the occlusal surface, followed by the same primer and sealant application protocol. All restorations are light-cured and clinically evaluated for voids and occlusion
Typ studiów
Zapisy (Szacowany)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Cairo, Egipt
- Faculty of Dentistry
-
Cairo, Egipt
- Yomna
-
Cairo, Egipt
- Faculty of Dentistry Cairo University
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dziecko
- Dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
Young adult Patients Aged 17-22.
- Good oral hygiene (plaque index score 0 or 1).
- Absence of abnormal occlusion habits (e.g. bruxism, nail biting, tooth clenching and mouth breathing).
- Patients approving to participate in the study.
Exclusion Criteria:
•Patients with known allergic or adverse reaction to the tested materials.
- Systematic disease that may affect participation.
- Xerostomic patients.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Zapobieganie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Podwójnie
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Aktywny komparator: Giomer Based Sealant Without Pre Treatmen
Giomer Based Sealant Without Pre Treatment With laser giomer based fissure sealnt will be applied without surface treatment
|
surface treatment with Bioactive Glass Air Abrasion giomer based fissure sealnt will be applied after surface treatment With laser
Inne nazwy:
|
|
Aktywny komparator: Giomer Based Sealant With etchant Pre Treatmen
Giomer Based Sealant Without Pre Treatment With laser giomer based fissure sealnt will be applied with phosphoric acid surface treatment
|
surface treatment with Bioactive Glass Air Abrasion giomer based fissure sealnt will be applied after surface treatment With laser
Inne nazwy:
|
|
Aktywny komparator: Giomer Based Sealant With laser Pre Treatmen
Giomer Based Sealant with laser Pre Treatment giomer based fissure sealnt will be applied with laser surface treatment
|
surface treatment with Bioactive Glass Air Abrasion giomer based fissure sealnt will be applied after surface treatment With laser
Inne nazwy:
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Loss of sealant's retention
Ramy czasowe: 1 year
|
Simonsen's criteria Full retention (FR) The material was fully present on the occlusal surfaces Partially lost (PL) The material was present, but as a result of either wear or loss of the material, part of a previously sealed pit or fissure, or both, was exposed- Totally lost (TL) No trace of the material was detected on the surface.
|
1 year
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Secondary Caries
Ramy czasowe: 1 year
|
Modified USPHS ( United States Public Health Service) criteria Alpha: Absence of the caries Charlie: Presence of the caries
|
1 year
|
Współpracownicy i badacze
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- Fissure sealant
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .