- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT01788150
Safety and Efficacy Study of the Svelte Drug-Eluting Coronary Stent Delivery System (DIRECT II)
Direct Implantation of Rapamycin-Eluting Stents With Bio-Erodible Drug Carrier Technology Utilizing the Second Generation Svelte Drug-Eluting Coronary Stent Integrated Delivery System (IDS)
A prospective, randomized, active-control, multi-center clinical trial comparing the safety and efficacy of the Svelte Drug-Eluting Coronary Stent Integrated Delivery System (IDS) to that of the commercially available Resolute IntegrityTM Drug-Eluting Stent.
The study objective is to assess the safety and efficacy of the Svelte Drug-Eluting Coronary Stent Integrated Delivery System (IDS) compared to the Resolute IntegrityTM Drug-Eluting Stent in patients with single, never previously treated coronary artery lesions
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Hamburg, Alemanha
- University Medical Center Hamburg-Eppendorf
-
Hamburg, Alemanha
- Medizinisches Verzorgungszentrum Prof. Mathey, Prof. Schofer
-
-
-
-
-
Aalst, Bélgica
- OLV Ziekenhuis Aalst
-
Antwerpen, Bélgica
- Middelheim Ziekenhuis
-
Genk, Bélgica
- ZOL Genk
-
Liege, Bélgica
- CHU Liège
-
-
-
-
-
Rouen, França
- Clinique Saint-Hilaire
-
Toulouse, França
- CHU de Toulouse
-
Toulouse, França
- Clinique Pasteur
-
-
-
-
-
Amsterdam, Holanda
- OLVG Amsterdam
-
Eindhoven, Holanda
- Catharina Hospital Eindhoven
-
Rotterdam, Holanda
- Maasstad ziekenhuis
-
Rotterdam, Holanda
- Erasmus MC
-
Utrecht, Holanda
- University Medical Center Utrecht, Department of Cardiology
-
-
-
-
-
Malmo, Suécia
- Skane University Hospital
-
Stockholm, Suécia
- Södersjukhuset
-
-
-
-
-
Bern, Suíça
- Inselspital
-
-
-
-
-
Prague, Tcheca
- Vseobecna fakultni nemocnice Praha
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
General Inclusion Criteria
- Patient is ≥18 years old;
- Patient is eligible for percutaneous coronary intervention (PCI);
- Patient is an acceptable candidate for emergent coronary artery bypass graft (CABG) surgery;
- Patient has clinical evidence of ischemic heart disease, stable or unstable angina, silent ischemia, or a positive functional study;
- Female subjects of childbearing potential must have a negative pregnancy test within 7-days before the trial procedure;
- Patient or subject's legal representative has been informed of the nature of the trial and agrees to its provisions and has provided written informed consent as approved by the Hospital Research Ethics Committee (HREC) of the respective investigational site; and
- Patient agrees to comply with specified follow-up evaluations and to return to the same investigational site where the procedure was performed.
Angiographic Inclusion Criteria
- Patient has either a single target lesion, or two lesions (target and non-target) located in separate coronary arteries;
If a non-target lesion is treated, it must be treated first and only with commercially available PTCA balloons and/or stents. Post PCI of the non-target vessel, all of the following conditions must be met:
- Residual diameter stenosis < 30%;
- Absence of any angiographic complications;
- Absence of ischemic symptoms; and
- Absence of significant new arrhythmia or ECG monitoring changes suggestive of ischemia.
- Reference vessel ≥ 2.5 mm and ≤ 3.5 mm in diameter by visual estimate;
- Target lesion < 20 mm in length by visual estimate (the intention is to cover the entire lesion with one stent of adequate length); and
- Target lesion stenosis ≥ 50% and < 100% by visual estimate.
Exclusion Criteria:
General Exclusion Criteria
- Patient is currently enrolled in another investigational device or drug trial that has not completed the primary endpoint or that clinically interferes with the current study endpoints Note: Trials requiring extended follow-up for products that were investigational, but have since become commercially available, are not considered investigational trials;
- The patient requires a staged procedure of the target vessel within 6-months or a staged procedure of a non-target vessel within 30-days post-procedure;
- The target lesion requires treatment with a device other than PTCA prior to stent placement (such as, but not limited to, directional coronary atherectomy, excimer laser, rotational atherectomy, etc.);
- Any DES deployment anywhere in the target vessel within the past 9-months;
- Any BMS deployment anywhere in the target vessel within the past 6-months;
- Any previous stent placement within 10 mm (proximal or distal) of the target lesion;
Myocardial infarction within 72-hours of the index procedure, with the exception of:
- Patients who have had a STEMI and PCI to the culprit lesion may be included if they have a suitable lesion in another vessel, and have been clinically and hemodynamically stable for 72-hours;
- Patients who have had a non-STEMI may be included if their troponin levels are within the laboratory normal range within 24-hours pre-procedure.
- Co-morbid condition(s) that could limit the patient's ability to participate in the trial or to comply with follow-up requirements, or impact the scientific integrity of the trial;
- Concurrent medical condition with a life expectancy of less than 12-months;
- Documented left ventricular ejection fraction (LVEF) ≤ 30%;
- Unstable angina pectoris from an extra-cardiac cause (Braunwald Class A I-III);
- Known allergies to the following: Acetylsalicylic acid (ASA), Clopidogrel bisulfate, Ticlopidine, Prasugrel, Rapamycin, Zotarolimus, PEAIII AcBz, Heparin/ Bivalirudin, or contrast agent (that cannot be adequately premedicated);
- Platelet count < 100,000 cells/mm3 or > 700,000 cells/mm3 or a WBC < 3.000 cells/mm3 or hemoglobin < 100g/l;
- Acute or chronic renal dysfunction (serum creatinine > 170μmol/L);
- History of a stroke or transient ischemic attack (TIA) within the prior 6-months;
- Active peptic ulcer or upper gastrointestinal (GI) bleeding within the prior 6-months;
- History of bleeding diathesis or coagulopathy or will refuse blood transfusions; and
- Patients requiring ongoing anticoagulation with warfarin or dabigatran.
Angiographic Exclusion Criteria
- Total occlusion (TIMI 0 or 1);
- Target vessel has angiographic evidence of thrombus
- Target vessel is excessively tortuous or has heavy calcification;
- Significant (> 50%) stenosis proximal or distal to the target lesion that might require revascularization or impede run off;
- Target lesion is located in or supplied by an arterial or venous bypass graft;
- Ostial target lesion (within 5.0 mm of vessel origin) or any location within the left main coronary artery;
- Target lesion involves a side branch > 2.0 mm in diameter; and
- Unprotected Left Main coronary disease (stenosis > 50%).
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Svelte Drug-Eluting Coronary Stent
Coronary Stenting
|
|
|
Comparador Ativo: Medtronic Resolute Integrity Drug-Eluting Stent
Coronary Stenting
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Angiographic In-Stent Late Lumen Loss (LL)
Prazo: 6-months post-procedure
|
Defined as the measurements either within the stented segment or within 5 mm proximal and distal to the stent edges.
|
6-months post-procedure
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Number of Participants Clinically-driven Target Lesion Revascularization (TLR)
Prazo: 1 year post-procedure
|
Clinically driven TLR is defined as revascularization performed on a patient who returns with clinical symptoms such as unstable angina, that is, chest pain that increases in frequency, intensity or duration.
|
1 year post-procedure
|
|
Number of Participants Composite of Cardiac Death, MI Attributed to the Target Vessel and Clinically Driven Target Lesion Revascularization
Prazo: 1 year post-procedure
|
Composite of cardiac death, MI attributed to the target vessel and clinically driven target lesion revascularization
|
1 year post-procedure
|
|
Number of Participants Composite of All-cause Mortality, Any MI and Any Revascularization, Target Vessel Revascularization or Revascularization of Non Target Vessels
Prazo: 1 year post-procedure
|
Composite of all-cause mortality, any MI and any revascularization, target vessel revascularization or revascularization of non target vessels
|
1 year post-procedure
|
|
Number of Participants Stent Thrombosis
Prazo: 1 year post-procedure
|
The sudden occlusion of a stented coronary artery due to thrombus formation.
|
1 year post-procedure
|
|
Number of Participants Acute Success Rates
Prazo: From index procedure to hospital discharge, an average of 24 hours
|
Direct Stenting Success, Lesion Success, Procedure Success and Device Failure
|
From index procedure to hospital discharge, an average of 24 hours
|
|
Number of Participants In-stent and In-segment Angiographic Binary Restenosis Rate
Prazo: 6-months post-procedure
|
The rate which restenosis occurs
|
6-months post-procedure
|
|
In-stent and In-segment Minimum Lumen Diameter
Prazo: 6-months post-procedure
|
Smallest diameter in the stent or segment area
|
6-months post-procedure
|
|
In-segment Late Lumen Loss
Prazo: 6-months post-procedure
|
Late lumen loss is the difference in millimeters between the diameter of a stented segment post-procedure compared with the follow-up angiogram
|
6-months post-procedure
|
|
Neointimal Hyperplasia as Measured by OCT
Prazo: 6-months post procedures
|
(% lumen volume)
|
6-months post procedures
|
|
Strut Coverage
Prazo: 6-months post procedure
|
(% of struts malapposed, protruding non-covered, protruding covered, non-protruding covered)
|
6-months post procedure
|
|
Number of Participants Target Vessel Failure
Prazo: 1 year post procedure
|
Composite endpoint of cardiac death, target vessel MI (Q or Non-Q wave), or clinically- driven target vessel revascularization (TVR) by percutaneous or surgical methods.
|
1 year post procedure
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Alexandre Abizaid, MD, PhD, Instituto Dante Pazzanese de Cardiologia
- Investigador principal: Stefan Verheye, MD, PhD, Antwerp Cardiovascular Institute
Publicações e links úteis
Links úteis
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- IP-12-002
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .