To improve the quality of fetal ultrasound images, self assessment is less resource consuming than assessment by an expert reviewer, and may be as effective.

To test this hypothesis, we randomize volunteer experienced ultrasonographers into two groups.

One group assess their own images (self assessment). The other group has their images assessed by an expert. Images are audited via the internet in a standardized procedure that generates feedback with recommendation for change.

Three to 6 months later, participants are audited again. If the improvement in image quality turns to be the same in both groups, it will be likely that self assessment is indeed as effective as assessment by an expert reviewer - at least for professionals experienced in fetal ultrasound.

Visão geral do estudo

Descrição detalhada

Background: Audit and feedback based on image scoring by an expert improve ultrasound image quality, but is time consuming. Self assessment of ultrasound still images might be an alternative to assessment by an expert.

Objective. To compare image quality improvement following self assessment of fetal biometry images versus audit and feedback by an expert.

Methods. Study design: prospective blinded randomised controlled trial. Inclusions Doctors or midwifes experienced in the field of fetal ultrasound, are solicited by email to enrol. Volunteers upload a first set of 30 biometry images (10 cephalic, 10 abdominal and 10 femoral) obtained from 10 consecutive screening scans performed in the second or third trimester of pregnancy. Abnormal scans are excluded.

Randomization:

After uploading the first set of images, ultrasonographers are randomised with a 1:1 ratio * Arm 1: Ultrasonographers assess their own images online according to a standardized procedure. They receive an automatically generated report with detailed recommendations for change.

Their images are also audited by an expert, but the result of this audit remains concealed to the ultrasonographer

* Arm 2: Ultrasonographers do not assess their own images. Their images are assessed by an expert according to the same standardized online procedure. They receive an automatically generated report with detailed recommendations for change.

Follow up Three to 6 months later, ultrasonographers are asked to upload a second set of 30 biometry images. Images are audited by an expert reviewer using the same standardized online procedure as for the first set.

Online image scoring procedure:

The procedure is the same whether the reviewer is the ultrasonographer himself or an expert.

Uploaded images are presented to the reviewer after an automatic black contour concealed the identity of the patient and ultrasonographer.

Images are presented on the left hand side of the screen. Buttons on the right hand side are clicked according to the presence or absence of quality criteria. Online help provides specifics on each criterion, together with typical images.

Scoring criteria are derived from L. J. SALOMON, et al Ultrasound Obstetric Gynecology 2006; 27: 34-40).

For each set of images sent by a given ultrasonographer, image quality is evaluated based on:

  • the percentage of images meeting all criteria (IMAC)
  • the mean of a score based on attributing one point per criterion present on a given image.

Feed back and recommendations for change A feedback adapted to the scoring results is generated automatically. It provides the ultrasonographer with the percentage of IMAC, and a mean score, overall and for each type of image. Whenever a criterion is not met, a pop up window shows the corresponding image and a short document is displayed, with recommendations for change.

Data collected:

  • Gestational age
  • Demographic characteristics of professionals enrolled: age, gender, experience in fetal ultrasound (years), medical doctor vs. midwife, fetal ultrasound practice (screening only, vs. screening plus referral ultrasound), medical practice other than fetal ultrasound, continuous medical education in the field of fetal biometry, membership of the French College of fetal ultrasonography.
  • For each set and type of image:
  • percentage of IMAC
  • mean score

Main outcome :

Improvement in the mean percentage of IMAC between the first and the second set of images

Secondary outcomes:

Improvement in the mean percentage of IMAC between the first and the second series of cephalic images Improvement in the mean percentage of IMAC between the first and the second series of abdomen images Improvement in the mean percentage of IMAC between the first and the second series of femur images Difference in mean score, overall and for each image type, between the first and the second set of images.

Subgroup analysis may be performed based on ultrasonographers characteristics. The agreement between self assessment and audit by expert reviewers will be analysed Statistical analysis A descriptive analysis of data will be done. An equivalence test for quantitative data will be done to study the main and secondary outcomes.

Subgroups analysis will be made for each image type. Agreement between self assessment and expert audit will be evaluated by intraclass correlation coefficient method.

For all tests, a value of P < 0.05 was considered statistically significant. Number of participants to be included The mean increase in the percentage of IMAC for each ultrasonographer (Δ% IMAC) is the main outcome. The equivalence in Δ% IMAC between the two arms will be tested.

We choose the following equivalence margins: ± 6.67% (i.e. a difference of 2 IMAC for each set of 30 images). The standard deviation of Δ% IMAC observed in a previous study was 20. This study showed a Δ% IMAC of 15% after audit and feedback (i.e. 4 to 5 images improved).

For a two sided alpha of 5% and a power of 80%, 156 ultrasonographers are needed in each group. We thus expect to enrol 320 ultrasonographers in the study.

Expected results. Equivalence in improvement of image quality in the self assessment and the expert audit group.

This would suggest that online self assessment may be as effective as audit by an expert to improve ultrasound image quality.

Tipo de estudo

Intervencional

Inscrição (Antecipado)

320

Estágio

  • Fase 3

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Montpellier, França, 34000
        • Recrutamento
        • Collège Français d'échographie Foetale
        • Contato:
          • Marc Dommergues, MD, PhD
      • ¨Paris, França, 75013
        • Recrutamento
        • Groupe Hospitalier Pitié Salpêtrière
        • Contato:
          • Marc Dommergues, MD, PhD

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Filho
  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion criteria :

  • Volunteer ultrasonographers
  • Single pregnancy
  • gestational age at ultrasound: 18-36

Exclusion criteria :

  • any fetal structural abnormality identified during ultrasound
  • multiple pregnancy

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: 1
self assessment of ultrasound fetal biometry images followed by automatically generated feedback
self assessment of ultrasound fetal biometry images followed by automatically generated feedback
Comparador Ativo: 2
assessment of ultrasound fetal biometry images by expert, followed by automatically generated feedback
assessment of ultrasound fetal biometry images by expert, followed by automatically generated feedback

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Prazo
Increase in the percentage of IMAC at 3-6 months after inclusion comparing the group with self-assessment and the group with assessment by expert.
Prazo: 3-6 months
3-6 months

Medidas de resultados secundários

Medida de resultado
Prazo
Increase in mean images quality score at 3-6 months comparing the group with self-assessment and the group with assessment by expert
Prazo: 3-6 months
3-6 months

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Investigador principal: Marc Dommergues, MD, PhD, Assistance Publique - Hôpitaux de Paris

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo

1 de julho de 2012

Conclusão Primária (Antecipado)

1 de setembro de 2014

Conclusão do estudo (Antecipado)

1 de setembro de 2014

Datas de inscrição no estudo

Enviado pela primeira vez

26 de fevereiro de 2014

Enviado pela primeira vez que atendeu aos critérios de CQ

27 de fevereiro de 2014

Primeira postagem (Estimativa)

28 de fevereiro de 2014

Atualizações de registro de estudo

Última Atualização Postada (Estimativa)

28 de fevereiro de 2014

Última atualização enviada que atendeu aos critérios de controle de qualidade

27 de fevereiro de 2014

Última verificação

1 de fevereiro de 2014

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • AOR08021

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever