To compare safety and efficacy of Endoscopic conventional technique (cyanoacrylate alone) to the EUS-guided injection technique (coil and cyanoacrylate) in the treatment of gastric varices.
Methods:
Patient recruitment:
Patients would be recruited from the endoscopy centre prior to their scheduled endoscopic intervention.
Study intervention :- Cyanoacrylate injection and EUS guided coil and glue injection The procedures would be performed by experienced endoscopists. The procedure would be performed under conscious sedation or monitored anaesthesia. The procedures would be performed by a therapeutic endoscope with the through the scope method. The endoscope would be used to reach the site of Varices. In Conventional technique treatment with cyanoacrylate the injection was performed using a 23-G sclerotherapy needle catheter (Interject®,Cook). One vial of N-butyl-2-cyanoacrylate (0.5 mL) was mixed with Lipiodol® in a 1:1 ratio, and injected intravesically as a 1 mL bolus. The injection was repeated until total hardening of the varix. In treatment with coil and cyanoacrylate once the gastric varix was identified, the total diameter of the vascular pseudotumor was measured and the puncture was made at the site of the widest varix. The puncture was performed using a 19 G needle (Expect®,Cook). The size of the coil used was selected based on the size of the widest varix in the pseudotumor; the size of the coil after release should not be greater than the caliber of the vessel. Following coil deployment, 2 mL of distilled water was injected, followed by one vial (0.5 mL) of N-butyl-2-cyanoacrylate mixed with Lipiodol in 1:1 ratio. Then, another 2 mL of distilled water was injected, and the needle was removed.
COIL and GLUE:
Cyanoacrylate injection remains the conventional treatment method. Since coils were first used to treat ectopic varices by Levy in 2008(6), this technique has been increasingly implemented into clinical practice. However, its higher cost has been a limiting factor in more widespread use.
Depending on the ectasia of the varix the following coil was deployed: 8 mm x 20 cm, 10 mm x 20 cm, or 10 mm x 30 cm (Interlock-18 Fibered IDC Occlusion System,Cook).
D.2.5 Randomization Patients were randomized into two groups: group I received standard endoscopic treatment with injection of a cyanoacrylate/Lipiodol (1:1) solution and group II received EUS-guided coiling and cyanoacrylate injection treatment A computer-based randomization list was generated with the online software Research Randomizer with 1:1 ratio (www.randomizer.org). An independent researcher not involved in this trial created the randomization list and sealed sequential opaque envelopes containing the random allocation sequence. The complete list generation occurred before the first enrollment.
D.2.6 Post-procedural management After the procedure, EUS with Doppler flow evaluation was repeated to check the presence or absence of flow within the varix. The patients remained under observation in the GI endoscopy unit for at least one hour, being released if no complaint was reported. After endoscopic treatment, all patients underwent thoracic and abdomen computerized tomography (CT) scanning within one week, independent of the development of clinical symptoms.
Visão geral do estudo
Descrição detalhada
All patients returned to the GI endoscopy unit approximately one month after initial endoscopic intervention for a repeat EUS evaluation.
Technical success is defined as complete obliteration of varices and absence of flow signal.On this occasion, if any residual flow was identified, new treatment was performed following the same technique initially used, and another evaluation was thus performed one month later. This scenario was repeated until complete thrombosis was achieved.
Complications that occurred during the procedure or within seven days post-intervention were defined as early complications, whereas those that occurred greater than or equal to seven days post-intervention were defined as late complications.
Recurrence was defined as evidence of any flow within the varix which occurred after initial obliteration had been confirmed.
5.Esophageal stricture 6.Iodine allergy (for EV)
Follow-up:
Once complete thrombosis was achieved, follow-up evaluations were performed three and nine months later (i.e. four and 10 months after therapy), at which time patients were questioned about any post-procedure complications, and underwent another EUS examination, which permitted repeat evaluations of flow within the treated vessel.
Tipo de estudo
Inscrição (Antecipado)
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
- Nome: Satya Maharshi Tummalapalli, MBBS MD
- Número de telefone: 04023378888
- E-mail: maharshi2059@gmail.com
Estude backup de contato
- Nome: RAJESH GOUD, M.PHARMA, MBA
- Número de telefone: 04023378888
- E-mail: rajeshgoud761@gmail.com
Locais de estudo
-
-
Telangana
-
Hyderabad, Telangana, Índia, 500082
- Recrutamento
- Asian Institute of Gastroenterology
-
Contato:
- SATYA MAHARSHI, MBBS MD
- Número de telefone: 04023378888
- E-mail: maharshi2059@gmail.com
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Age ≥18 years old, patients diagnosed with
- gastric varices larger than 2.0 cm in total diameter of the vascular pseudotumor type GOV2 or IGV 1.
- Active bleeder
- Secondary prophylaxis - h/o previous bleed
- High risk GV (GOV 2/IGV 1) - Baveno VI-
- Primary prophylaxis
Excusion criteria:
- Previous HRS
- MOF
- Platelet <50,000/cumm
- INR>2
- Esophageal stricture
- Iodine allergy (for EV)
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Dobro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Comparador Ativo: Cyanoacrylate injection and EUS guided coil and glue injection
The procedure would be performed under conscious sedation.The endoscope would be used to reach the site of Varices.
In Conventional technique treatment with cyanoacrylate the injection was performed using a 23-G sclerotherapy needle catheter .
One vial of N-butyl-2-cyanoacrylate (0.5 mL) was mixed with Lipiodol) in a 1:1 ratio, and injected intravesically as a 1 mL bolus.
The injection was repeated until total hardening of the varix.
In treatment with coil and cyanoacrylate once the gastric varix was identified, the total diameter of the vascular pseudotumor was measured and the puncture was made at the site of the widest varix.
The puncture was performed using a 19 G needle .
the size of the coil after release should not be greater than the caliber of the vessel.
Following coil deployment, 2 mL of distilled water was injected, followed by one vial (0.5 mL) of N-butyl-2-cyanoacrylate mixed with Lipiodol in 1:1 ratio.
|
The procedures would be performed by a therapeutic endoscope with the through the scope method.
The endoscope would be used to reach the site of Varices.
|
|
Comparador de Placebo: COIL and GLUE
Cyanoacrylate injection, first published by Soehendra in 1986, remains the conventional treatment method. Since coils were first used to treat ectopic varices by Levy in 2008(6), this technique has been increasingly implemented into clinical practice. However, its higher cost has been a limiting factor in more widespread use. Depending on the ectasia of the varix the following coil was deployed: 8 mm x 20 cm, 10 mm x 20 cm, or 10 mm x 30 cm (Interlock-18 Fibered IDC Occlusion System,Cook). |
The procedures would be performed by a therapeutic endoscope with the through the scope method.
The endoscope would be used to reach the site of Varices.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Primary outcome was to compare the occurrence of embolism in the two groups
Prazo: 4 months
|
Technical success is defined as complete obliteration of varices and absence of flow signal.On this occasion, if any residual flow was identified, new treatment was performed following the same technique initially used, and another evaluation was thus performed one month later.
This scenario was repeated until complete thrombosis was achieved.
|
4 months
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Secondary outcome was to evaluate the efficacy of the two techniques in the eradication of the varices.
Prazo: 9 MONTHS
|
Technical success is defined as complete obliteration of varices and absence of flow signal.On this occasion, if any residual flow was identified, new treatment was performed following the same technique initially used, and another evaluation was thus performed one month later.
This scenario was repeated until complete thrombosis was achieved.
|
9 MONTHS
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Diretor de estudo: RAJESH GUPTA, MBBS MD, Asian Institute of Gastroenterology Pvt Ltd
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Antecipado)
Conclusão do estudo (Antecipado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- EUS GLUE 001
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .