- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07575503
Diagnostic Value of Photon-Counting CT in Subsegmental Pulmonary Embolism
Application of Photon-Counting Computed Tomography in the Diagnosis of Subsegmental Pulmonary Embolism
Pulmonary embolism (PE) is a serious and potentially life-threatening condition caused by blood clots in the lungs. A particular type, subsegmental pulmonary embolism (SSPE), involves very small branches of the pulmonary arteries. Although these clots occur in smaller vessels, their risk of recurrence and complications may be similar to larger clots.
Conventional CT pulmonary angiography (CTPA) is the standard imaging test for suspected PE, but image quality can sometimes be limited by motion artifacts, poor contrast filling, or body habitus, making the detection of SSPE challenging.
Photon-counting computed tomography (PCCT) is a new CT technology that provides higher image resolution, lower radiation dose, and improved visualization of small blood vessels. Early studies suggest PCCT may reduce motion artifacts and increase the accuracy of detecting SSPE compared with conventional CT.
This prospective cohort study will compare PCCT with dual-source CT in patients with suspected acute PE. The study aims to determine whether PCCT improves the detection rate and image quality for SSPE, and whether it can provide more reliable diagnostic information to guide clinical care.
Visão geral do estudo
Status
Descrição detalhada
Pulmonary embolism (PE) is a leading cause of morbidity and mortality worldwide. Subsegmental pulmonary embolism (SSPE), defined as thrombi confined to subsegmental pulmonary arteries, may account for up to 20% of acute PE cases detected by multidetector CT. While distal in location, SSPE carries a risk of recurrent venous thromboembolism and mortality that is comparable to more proximal PE, suggesting that SSPE is not a benign entity. Accurate diagnosis is therefore clinically important, but remains challenging due to motion artifacts, poor contrast opacification, and the large number of small subsegmental vessels that must be evaluated.
Photon-counting computed tomography (PCCT) is a recently developed imaging technology that offers significant improvements over conventional energy-integrating detector CT (EID-CT). PCCT provides higher spatial resolution, direct spectral information, and the ability to generate virtual monoenergetic images and iodine maps in a single acquisition, while reducing radiation dose. Preliminary studies indicate that PCCT can minimize motion artifacts, improve image quality, and enhance visualization of small pulmonary arteries, potentially increasing the detection of SSPE.
This prospective observational cohort study will compare the diagnostic performance of PCCT with dual-source CT in patients with suspected acute PE. The primary outcome is the detection rate of SSPE. Secondary outcomes include image quality scores, radiation dose, and the added diagnostic value of PCCT in patients with negative findings on dual-source CT. By systematically evaluating image quality, detection yield, and radiation exposure, this study seeks to establish the potential role of PCCT as a superior diagnostic tool for SSPE in real-world clinical practice.
Tipo de estudo
Inscrição (Estimado)
Contactos e Locais
Locais de estudo
-
-
Zhejiang
-
Hangzhou, Zhejiang, China, 310009
- Recrutamento
- The second Affiliated Hospital of Zhejiang University School of Medicine
-
Contato:
- min Yan, doctor
- Número de telefone: +86 13757118632
- E-mail: zryanmin@zju.edu.cn
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- Age ≥ 18 years
Clinical manifestations supporting the diagnosis of acute pulmonary embolism, including:
Acute onset or progressive dyspnea Unexplained hypoxemia Chest pain Hemoptysis Syncope or presyncope Combined with abnormal findings on electrocardiogram, echocardiography, or pulse oximetry
- Revised simplified Geneva score ≥ 3
- Written informed consent obtained from the patient or the patient's legally authorized representative
Exclusion Criteria:
- Patients requiring prophylactic or therapeutic doses of anticoagulant medication for reasons other than venous thromboembolism (VTE).
- Life expectancy less than three months.
- Patients unable to undergo CT scanning due to severe condition or hemodynamic instability.
- History of allergy to contrast media, renal insufficiency (creatinine clearance < 30 mL/min), or ongoing long-term dialysis.
- Pregnancy.
- Refusal to provide informed consent or inability to complete follow-up for any reason.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
|---|
|
Group 1Title: Conventional CT group
Description: Patients with suspected pulmonary embolism who undergo dual-source or energy-integrating detector CT pulmonary angiography (EID-CTPA).
|
|
Group 2 Title: Photon-counting CT group
Description: Patients with suspected pulmonary embolism who undergo photon-counting computed tomography (PCCT) for diagnosis.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Detection rate of subsegmental pulmonary embolism (SSPE) using photon-counting CT versus dual-energy CT
Prazo: perioperative period
|
The proportion of patients with suspected acute pulmonary embolism in whom SSPE is detected on photon-counting CT compared with dual-energy CT.
All scans will be independently assessed by two blinded radiologists to determine diagnostic yield.
|
perioperative period
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Objective image quality scores for SSPE diagnosis
Prazo: perioperative period
|
ignal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) will be calculated based on CT attenuation and image noise measured in standardized Regions of Interest (ROIs) within pulmonary vessels, the aorta, and paraspinal muscles.
Higher SNR and CNR values indicate better objective image quality.
|
perioperative period
|
|
Subjective image quality scores for SSPE diagnosis
Prazo: perioperative period
|
Radiologists will qualitatively assess image noise and motion artifacts using a 5-point Likert scale (1 = Unacceptable, 5 = Excellent).
The average score of the readers will be used, with higher scores indicating better subjective image quality
|
perioperative period
|
|
Incidence of Venous Thromboembolism (VTE)
Prazo: 3 months
|
Occurrence of symptomatic VTE, defined as Deep Vein Thrombosis (DVT) or Pulmonary Embolism (PE), confirmed by objective imaging upon clinical suspicion
|
3 months
|
Colaboradores e Investigadores
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Outros números de identificação do estudo
- 2025-1248
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .