Posture, Interface, and Peak Cough Flow (PCF P/I)
Body Posture and Interface Effects on Peak Cough Flow in Healthy Adults: A Randomized Crossover Study
Cough is a key airway protective mechanism requiring coordinated neuromuscular function. Peak cough flow (PCF) is a simple, non-invasive measure widely used to assess cough effectiveness and guide clinical decisions. Current ATS/ERS guidelines recommend measuring PCF in a seated position using a mouthpiece with a nose clip; however, this setup is not always feasible in clinical practice. Some patients cannot maintain posture or ensure an adequate mouthpiece seal, making a facial mask a potential alternative. The influence of body position and interface on PCF measurements remains unclear, with limited evidence from randomized crossover studies.
This study aims to evaluate the effects of body position (sitting vs standing) and measurement interface (mouthpiece vs facial mask) on PCF in healthy young adults. In a randomized within-subject crossover design, participants perform PCF measurements under four conditions (Sit-Mask, Stand-Mask, Sit-Mouthpiece, Stand-Mouthpiece) during a single session. The findings will help inform more flexible and standardized PCF assessment procedures in clinical practice.
Visão geral do estudo
Status
Condições
Descrição detalhada
Cough is an essential protective mechanism that requires intact neuromuscular function and precise coordination across the inspiratory, compressive, and expulsive phases. Peak cough flow (PCF) is a simple, non-invasive measure, widely used to assess cough intensity and guide clinical decisions. Because of its clinical relevance, standardized procedures are essential. Current ATS/ERS recommendations specify seated testing with a mouthpiece and a noseclip (MP). However, this configuration is not always possible or consistently used in practice. Many patients cannot maintain adequate posture or mouthpiece seal, and a facial mask (FM) may be a feasible alternative. Evidence regarding the effects of posture (sitting vs standing) and interface (MP vs FM) on PCF remains inconsistent, with few studies comparing both factors within the same individuals using a randomized crossover design.
Aims To determine the effects of body position (sitting vs standing) and measurement interface (FM vs MP) on PCF in healthy young adults. We hypothesized that both factors would influence PCF.
Methods This randomized within subject crossover study included healthy, non smoking adults aged 20-30 years. Exclusion criteria were chronic disease, top-level athletic status and any signs of obstruction and/or auscultatory noise (wheezing or stridor) before the trial. Each participant completed four randomized conditions during a single session: Sit-Mask, Stand-Mask, Sit-Mouthpiece, and Stand-Mouthpiece. PCF (L/s) was measured using an ultrasonic spirometer (SpiroScout, Ganshorn). For each condition, participants performed three standardized maneuvers consisting of three tidal breaths, a rapid inspiration to total lung capacity, and a maximal cough; the highest PCF per condition was used for analysis. A two factor repeated measures ANOVA evaluated the effects of posture, interface, and their interaction (α = 0.05).
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Brussels, Bélgica, 1180
- Cliniques universitaires Saint-Luc
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
- Healthy adults aged 20 to 30 years
- Non-smoker
- Self-reported good health status
- Able to perform all four randomized cough conditions
Exclusion Criteria:
- Any chronic disease
- Signs of airway obstruction on clinical examination
- Auscultatory abnormalities (wheezing or stridor) prior to testing
- Incomplete participation in all four conditions
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Outro
- Alocação: Randomizado
- Modelo Intervencional: Atribuição cruzada
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Comparador Ativo: Sit-Mask
|
Peak cough flow measured in the seated position.
The facial mask (V2 Mask™, Hans Rudolph, Inc., Kansas, USA; size fitted to participant) was connected to an ultrasonic spirometer (SpiroScout, Ganshorn) via a PFT filter.
Participants performed three tidal breaths followed by a maximal cough, repeated three times.
Peak cough flow measured in the standing position.
Same device and procedure as Sit-Mask condition.
|
|
Comparador Ativo: Stand-Mask
|
Peak cough flow measured in the seated position.
The facial mask (V2 Mask™, Hans Rudolph, Inc., Kansas, USA; size fitted to participant) was connected to an ultrasonic spirometer (SpiroScout, Ganshorn) via a PFT filter.
Participants performed three tidal breaths followed by a maximal cough, repeated three times.
Peak cough flow measured in the standing position.
Same device and procedure as Sit-Mask condition.
|
|
Comparador Ativo: Sit-Mouthpiece
|
Peak cough flow measured in the seated position.
The mouthpiece (Pulmosafe, Lemon Medical GmbH, Hammelburg, Germany) was used with a nose clip and connected to an ultrasonic spirometer (SpiroScout, Ganshorn) via a PFT filter.
Participants performed three tidal breaths followed by a maximal cough, repeated three times.
Peak cough flow measured in the standing position.
Same device and procedure as Sit-Mouthpiece condition.
|
|
Comparador Ativo: Stand-Mouthpiece
|
Peak cough flow measured in the seated position.
The mouthpiece (Pulmosafe, Lemon Medical GmbH, Hammelburg, Germany) was used with a nose clip and connected to an ultrasonic spirometer (SpiroScout, Ganshorn) via a PFT filter.
Participants performed three tidal breaths followed by a maximal cough, repeated three times.
Peak cough flow measured in the standing position.
Same device and procedure as Sit-Mouthpiece condition.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Peak cough Flow (PCF)
Prazo: Day 1
|
PCF measurement in L/s
|
Day 1
|
Colaboradores e Investigadores
Publicações e links úteis
Publicações Gerais
- Miller MR, Hankinson J, Brusasco V, Burgos F, Casaburi R, Coates A, Crapo R, Enright P, van der Grinten CP, Gustafsson P, Jensen R, Johnson DC, MacIntyre N, McKay R, Navajas D, Pedersen OF, Pellegrino R, Viegi G, Wanger J; ATS/ERS Task Force. Standardisation of spirometry. Eur Respir J. 2005 Aug;26(2):319-38. doi: 10.1183/09031936.05.00034805. No abstract available.
- Brennan M, McDonnell MJ, Duignan N, Gargoum F, Rutherford RM. The use of cough peak flow in the assessment of respiratory function in clinical practice- A narrative literature review. Respir Med. 2022 Mar;193:106740. doi: 10.1016/j.rmed.2022.106740. Epub 2022 Jan 15.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 2023/14JUI/264
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .