- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07651943
AI-Assisted Interpretation of Ultra-Widefield Retinal Images
Prospective Multi-Center Evaluation of AI-Assisted Interpretation of Ultra-Widefield Retinal Images in a Multi-Reader Crossover Study
The goal of this prospective observational study is to evaluate the impact of artificial intelligence (AI) assistance on clinician interpretation of ultra-widefield (UWF) retinal images.
The main questions it aims to answer are:
whether AI assistance improves the diagnostic performance of ophthalmologists in detecting retinal findings on UWF retinal images; whether AI assistance improves sensitivity, specificity, and inter-reader agreement across clinicians with different levels of experience.
Approximately 600 UWF retinal images prospectively collected from multiple ophthalmic centers in China will be included. Images will be independently annotated by expert retinal specialists to establish reference labels for retinal finding categories.
Four ophthalmologists with different levels of clinical experience, including one senior retinal specialist and three junior ophthalmologists, will participate in a crossover multi-reader study.
For each clinician, the dataset will be randomly divided into two equal subsets. During the first reading session, clinicians will evaluate one subset without AI assistance and the other subset with AI assistance. After a washout interval of at least two weeks, the reading conditions will be reversed in a second reading session with independently randomized image order.
Under the AI-assisted condition, clinicians will be provided with category-level AI prediction probabilities for retinal findings. No localization maps, heatmaps, segmentation overlays, or automated diagnostic recommendations will be displayed. Clinicians will retain full autonomy over final decisions.
Reader performance under AI-assisted and unaided conditions will be compared using expert reference annotations as the ground truth.
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
This study is a prospective multi-center observational reader study designed to evaluate the impact of artificial intelligence (AI) assistance on clinician interpretation of ultra-widefield (UWF) retinal images.
Approximately 600 UWF retinal images will be prospectively collected from multiple ophthalmic centers in China. Images will be acquired using clinically routine UWF retinal imaging systems and will include a broad spectrum of retinal diseases and retinal findings encountered in real-world clinical practice.
All images will undergo independent expert annotation by retinal specialists to establish reference labels for retinal finding categories. These expert annotations will serve as the reference standard for subsequent performance evaluation.
Four ophthalmologists with different levels of clinical experience will participate in the reader study, including:
one senior retinal specialist with approximately five years of retinal clinical experience; three junior ophthalmologists with approximately two years of ophthalmology residency training.
A randomized crossover multi-reader design will be implemented to minimize recall bias and balance reading conditions.
For each clinician, the image dataset will be randomly divided into two equal subsets (subset A and subset B; approximately 300 images each).
During Round 1:
subset A will be interpreted without AI assistance; subset B will be interpreted with AI assistance.
After a washout interval of at least two weeks, the reading conditions will be reversed during Round 2:
subset A will be interpreted with AI assistance; subset B will be interpreted without AI assistance.
Image order will be independently randomized for each session and each clinician.
Under the unaided condition, clinicians will evaluate retinal images using standard clinical interpretation without AI output.
Under the AI-assisted condition, clinicians will receive category-level AI prediction probabilities for retinal finding categories. The AI output will provide probabilistic confidence scores only and will not include lesion localization maps, heatmaps, segmentation overlays, or automated binary recommendations.
Clinicians will remain blinded to the expert reference labels and to the interpretations of other readers. Final diagnostic decisions will be independently determined by each clinician.
The primary analysis will compare diagnostic performance between unaided and AI-assisted conditions, including sensitivity, specificity, area under the receiver operating characteristic curve (AUC), and inter-reader agreement.
Tipo de estudo
Inscrição (Real)
Contactos e Locais
Locais de estudo
-
-
Chongqing Municipality
-
Chongqing, Chongqing Municipality, China
- Chongqing Huaxia Eye Hospital
-
-
Fujian
-
Fuzhou, Fujian, China, 361000
- Fuzhou Eye Hospital
-
Xiamen, Fujian, China, 361000
- Xiamen Eye Center of Xiamen University
-
-
Hebei
-
Hengshui, Hebei, China
- Hengshui Tongrui Eye Hospital
-
-
Shandong
-
Heze, Shandong, China
- Heze Huaxia Eye Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- Participants undergoing ultra-widefield retinal imaging at participating ophthalmic centers;
Exclusion Criteria:
- Poor-quality or ungradable retinal images;
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
AI-Assisted Interpretation
Clinicians interpret ultra-widefield retinal images with access to AI-generated category-level prediction probabilities for retinal findings.
|
Clinicians interpret ultra-widefield retinal images with access to AI-generated category-level prediction probabilities for retinal findings.
|
|
Unaided Interpretation
Clinicians interpret ultra-widefield retinal images without AI assistance using routine retinal image interpretation alone.
|
Clinicians interpret ultra-widefield retinal images without AI assistance using routine retinal image interpretation alone.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Sensitivity for retinal finding detection
Prazo: through study completion, an average of 2 months
|
Sensitivity of clinicians in detecting retinal finding categories under AI-assisted and unaided conditions using expert annotations as the reference standard.
|
through study completion, an average of 2 months
|
|
Specificity for retinal finding detection
Prazo: through study completion, an average of 2 months
|
Specificity of clinicians in detecting retinal finding categories under AI-assisted and unaided conditions.
|
through study completion, an average of 2 months
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Area under the receiver operating characteristic curve (AUC)
Prazo: through study completion, an average of 2 months
|
The AUC quantifies the overall ability to correctly distinguish the presence versus absence of predefined retinal findings on ultra-widefield retinal images.
AUC values range from 0.5 (no discriminative ability) to 1.0 (perfect discrimination).
Clinician interpretations will be compared with an expert-adjudicated reference standard under AI-assisted and unaided conditions.
|
through study completion, an average of 2 months
|
|
Inter-reader agreement
Prazo: At study completion (up to 3 months)
|
Agreement among participating clinicians in classifying predefined retinal findings on ultra-widefield retinal images.
Agreement will be quantified using Cohen's kappa coefficient (for pairwise comparisons) or Fleiss' kappa coefficient (for multiple readers).
Kappa values range from 0 (no agreement beyond chance) to 1 (perfect agreement).
|
At study completion (up to 3 months)
|
|
Diagnostic performance improvement among junior ophthalmologists
Prazo: At study completion (up to 3 months)
|
Improvement in diagnostic performance of junior ophthalmologists when interpreting ultra-widefield retinal images with AI assistance compared with unaided interpretation, measured by changes in sensitivity, specificity, accuracy, and AUC using the expert-adjudicated reference standard.
|
At study completion (up to 3 months)
|
Colaboradores e Investigadores
Investigadores
- Investigador principal: Xiuju Chen, Xiamen Eye Center of Xiamen University
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- XMYKZX-KY-2026-008
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Descrição do plano IPD
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .