Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Follow-up After Percutaneous Device Closure of Ventricular Septal Defects

15 de julho de 2026 atualizado por: Noran Hasan Megally, Assiut University

Outcomes and Short-term Follow-up After Percutaneous Device Closure of Ventricular Septal Defects: A Study From Two Tertiary Pediatric Cardiac Care Centers in Upper Egypt

Ventricular septal defects (VSDs) are the most common congenital heart defects, accounting for 30-40% of congenital cardiac anomalies. They result from an abnormal opening in the interventricular septum, leading to left-to-right shunting. Clinical presentation depends on defect size and pulmonary vascular resistance, ranging from asymptomatic small defects to heart failure symptoms in infancy, with older children developing exercise intolerance or pulmonary hypertension.

Although surgical closure has long been the standard treatment, percutaneous transcatheter device closure has emerged as a less invasive alternative for selected VSD types, particularly muscular and suitable perimembranous defects. This approach offers comparable efficacy with reduced morbidity and shorter hospital stays.

This bicentric study aims to evaluate procedural success, complications, and short-term outcomes of percutaneous VSD closure in paediatric patients from Upper Egypt, providing essential data to guide clinical practice and quality improvement in tertiary cardiac centres.

Visão geral do estudo

Descrição detalhada

Ventricular septal defects (VSDs) are the most common congenital heart defects, accounting for 30-40% of congenital cardiac anomalies. They result from an abnormal opening in the interventricular septum, leading to left-to-right shunting. Clinical presentation depends on defect size and pulmonary vascular resistance, ranging from asymptomatic small defects to heart failure symptoms in infancy, with older children developing exercise intolerance or pulmonary hypertension.

Diagnosis is primarily established by transthoracic echocardiography, which accurately defines defect anatomy, shunt severity, ventricular function, and pulmonary artery pressures. Management is individualized according to hemodynamic significance, with small asymptomatic defects managed conservatively and significant defects requiring intervention following initial medical therapy.

Although surgical closure has long been the standard treatment, percutaneous transcatheter device closure has emerged as a less invasive alternative for selected VSD types, particularly muscular and suitable perimembranous defects. This approach offers comparable efficacy with reduced morbidity and shorter hospital stays.

Recent studies report high procedural success rates (95-98%) using evolving device technologies, including Amplatzer™ and newer asymmetric occluders. However, outcome data from developing regions remain limited, highlighting the need for population-specific evidence.

This bicentric study aims to evaluate procedural success, complications, and short-term outcomes of percutaneous VSD closure in paediatric patients from Upper Egypt, providing essential data to guide clinical practice and quality improvement in tertiary cardiac centres.

Tipo de estudo

Observacional

Inscrição (Estimado)

85

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Filho
  • Adulto

Aceita Voluntários Saudáveis

Não

Método de amostragem

Amostra Não Probabilística

População do estudo

Paediatric patients (age ≤18 years) undergoing percutaneous device closure of VSDs at the participating centres

Descrição

Inclusion Criteria:

  1. Age: 6 months to 18 years
  2. Confirmed diagnosis of VSD (perimembranous, muscular) by transthoracic echocardiography (TTE)
  3. Hemodynamically significant VSD with: (Imtiaz et al., 2023)

    • Pulmonary blood flow (Qp) to Systemic blood flow (Qs) ≥1.5:1, OR
    • Evidence of left ventricular volume overload, OR
    • Pulmonary arterial hypertension (PAH) with reversible pulmonary vascular resistance
  4. Suitable anatomy for device closure as assessed by TTE and/or transesophageal echocardiography (TEE)
  5. Adequate rim (≥2mm) from VSD edges to cardiac valves and conduction system (for perimembranous VSDs)
  6. Written informed consent from parents/legal guardians
  7. Assent from children ≥ 12 years (as appropriate

Exclusion Criteria:

  1. Active endocarditis or systemic infection
  2. Fixed, irreversible pulmonary arterial hypertension (pulmonary vascular resistance >8 Wood units/m² or ratio of pulmonary vascular resistance (Rp) to systemic vascular resistance (Rs) >0.5)
  3. Multiple VSDs not amenable to device closure
  4. VSD associated with complex congenital heart disease requiring surgical intervention
  5. Contraindication to antiplatelet therapy
  6. Known allergy to device materials (nickel-titanium alloy)
  7. Patient or family unwilling to comply with follow-up protocol
  8. Life expectancy <1 year due to non-cardiac conditions
  9. Body weight <5 kg (relative contraindication, case-by-case assessment)

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Procedural success rate
Prazo: baseline
To evaluate the procedural success rate and immediate safety of percutaneous device closure of VSDs in paediatric patients.
baseline
Assess short-term complications
Prazo: baseline
To assess short-term complications, including residual shunts, rhythm disturbances (especially AV block), and device-related adverse events during follow-up up to 6 months
baseline
Predictors of success and complications
Prazo: baseline
To evaluate clinical, echocardiographic outcomes and compare predictors of success and complications between the two tertiary centres
baseline

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

1 de agosto de 2026

Conclusão Primária (Estimado)

1 de outubro de 2027

Conclusão do estudo (Estimado)

1 de agosto de 2028

Datas de inscrição no estudo

Enviado pela primeira vez

15 de julho de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

15 de julho de 2026

Primeira postagem (Real)

20 de julho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

20 de julho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

15 de julho de 2026

Última verificação

1 de julho de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • Closure of VSD

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Sim

produto fabricado e exportado dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever