Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Validation of a Novel Incremental Step Test for Assessment of Cardiopulmonary Fitness and Ventilatory Thresholds in Adults (VALID-IST)

14 de setembro de 2026 atualizado por: David King, Heriot-Watt University
The purpose of this single-group diagnostic validation and test-retest reliability study is to determine whether a novel Incremental Step Test (IST) can accurately assess cardiorespiratory fitness and ventilatory thresholds in healthy adults compared with an established laboratory-based cycle ergometer Cardiopulmonary Exercise Test (CPET). The main questions are whether the step test can elicit reliable physiological responses sufficient to identify the anaerobic threshold and respiratory compensation point, and whether it produces reproducible results when repeated under standardised conditions. The study will compare the incremental step test (IST) with CPET to assess whether the IST provides similar peak and submaximal physiological measures and agreement with CPET comparator. Participants will complete three laboratory exercise tests across separate visits: one maximal CPET on a cycle ergometer, followed by two repeated ISTs performed on a 25 cm step board following the audio metronome.

Visão geral do estudo

Descrição detalhada

Participants will attend three laboratory visits separated by at least 3 days and conducted at similar times of the day. The first visit will include screening, anthropometric assessment, and a maximal CPET on an electronically braked cycle ergometer using a ramp protocol of 25 W/min for males and 20 W/min for females. Participants will complete 3 minutes of unloaded cycling followed by incremental protocol while maintaining the cadence at least 60 rpm, and the test will be terminated if they can no longer can sustain this cadence. Following CPET, participants will complete a 6-minute familiarisation session to practise the stepping activity, including the up-up-down-down stepping technique and alternation of the leading leg every 2 minutes. The second and third visits will involve repeated IST trials performed on 25 cm step board, with cadence progressed from 20 beats per minute and increased by 4 beats per minute every 20 seconds until volitional exhaustion. The IST will be terminated if the participant is unable to maintain the prescribed stepping rhythm for more than 15 seconds. Continuous breath-by-breath gas exchange, ECG, and heart rate monitoring will be used during testing to characterise peak performance and ventilatory threshold responses. Agreement between the step test and CPET, as well as test-retest reproducibility of the IST, will be evaluated to determine whether the new protocol could support more individualised exercise prescription in stepping-based activities.

Tipo de estudo

Intervencional

Inscrição (Estimado)

30

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Edinburgh, Reino Unido, EH14 4AS
        • Oriam Scotlant Performance Centre

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto

Aceita Voluntários Saudáveis

Sim

Descrição

Inclusion Criteria:

  1. Healthy adults aged 18 to 55 years.
  2. Body mass index between 18.5 and 29.9 kg/m².
  3. Non-smoker.
  4. No known cardiovascular, respiratory, metabolic, neurological, or musculoskeletal conditions that would contraindicate maximal exercise testing.
  5. Able to provide written informed consent.
  6. Willing and able to complete one Cardiopulmonary Exercise Test and two Incremental Step Test sessions.

Exclusion Criteria:

  1. Age younger than 18 years or older than 55 years.
  2. Body mass index below 18.5 kg/m² or above 29.9 kg/m².
  3. Current smoker or use of nicotine products.
  4. Known cardiovascular, respiratory, metabolic, neurological, or musculoskeletal conditions that may affect exercise performance or make maximal exercise testing unsafe.
  5. Any contraindication to maximal exercise testing according to established exercise testing guidelines.
  6. Use of medications known to significantly affect cardiovascular, respiratory, or metabolic responses to exercise.
  7. Current injury, illness, or infection that may limit participation in exercise testing.
  8. Pregnancy.
  9. Inability to provide informed consent.
  10. Inability to complete study procedures or attend all required study visits.

    -

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Diagnóstico
  • Alocação: N / D
  • Modelo Intervencional: Atribuição de grupo único
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Incremental Step Test Validation Protocol
Participants will complete one laboratory-based Cardiopulmonary Exercise Test followed by two Incremental Step Test sessions conducted on separate visits. The first visit will include screening, anthropometric measurements, and a maximal incremental CPET on an electronically braked cycle ergometer using an individualised ramp protocol set at 25 W/min for males and 20 W/min for females, after 3 minutes of unloaded cycling. The second and third visits will involve two repeated incremental step tests on a standardised 25 cm step, with cadence starting at 20 beats per minute and increasing by 4 beats per minute every 20 seconds until volitional exhaustion. The CPET will be terminated if participants could not maintain a cadence of at least 60 rpm, and the step test will be terminated if participants could not maintain the prescribed stepping rhythm for 15 consecutive seconds. Exercise ECG, continuous heart rate, and breath-by-breath gas exchange will be recorded during all exercise tests.
A maximal incremental exercise test performed on a cycle ergometer with continuous breath-by-breath gas exchange and heart rate monitoring to assess cardiorespiratory fitness and physiological response
A progressive step test using a standardised 25 cm step platform. Participants will complete a 3-minute warm-up at 20 beats per minute before cadence increases by 4 beats per minute every 20 seconds until volitional exhaustion or predefined termination criteria are reached.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Between-method agreement in oxygen uptake at Anaerobic Threshold (AT)
Prazo: Baseline (Day 1-CPET) and IST assessments at Visits 2 and 3, scheduled at 3-7-day intervals.
Agreement between the Incremental Step Test and the established laboratory-based cycle ergometer Cardiopulmonary Exercise Test comparator for oxygen uptake at Anaerobic Threshold (mL/min), will be assessed using intraclass correlation coefficients and Bland-Altman analysis.
Baseline (Day 1-CPET) and IST assessments at Visits 2 and 3, scheduled at 3-7-day intervals.
Between-method agreement in oxygen uptake at Respiratory Compensation Point (RCP)
Prazo: Baseline (Day 1-CPET) and IST assessments at Visits 2 and 3, scheduled at 3-7-day intervals.
Agreement between the Incremental Step Test and the established laboratory-based cycle ergometer Cardiopulmonary Exercise Test comparator for oxygen uptake at Respiratory Compensation point / Ventilatory Threshold 2 (mL/min), will be assessed using intraclass correlation coefficients and Bland-Altman analysis.
Baseline (Day 1-CPET) and IST assessments at Visits 2 and 3, scheduled at 3-7-day intervals.
Between-method agreement in Peak Oxygen Uptake (VO2peak)
Prazo: Baseline (Day 1-CPET) and IST assessments at Visits 2 and 3, scheduled at 3-7-day intervals.
Peak oxygen uptake will be defined as the highest 30-second rolling average value recorded prior to test termination.
Baseline (Day 1-CPET) and IST assessments at Visits 2 and 3, scheduled at 3-7-day intervals.

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Test-retest reliability of oxygen uptake at Anaerobic Threshold (AT)
Prazo: (Day 3-IST Visit 2) and IST Visit 3, scheduled 3-7 days apart.
Test-retest reliability of oxygen uptake at AT (mL/min) derived from the Incremental Step Test (IST) between the first and second IST visits.
(Day 3-IST Visit 2) and IST Visit 3, scheduled 3-7 days apart.
Test-retest reliability of oxygen uptake at Respiratory compensation point (RCP)
Prazo: (Day 3-IST Visit 2) and IST Visit 3, scheduled 3-7 days apart.
Test-retest reliability of oxygen uptake at RCP (mL/min) derived from the Incremental Step Test (IST) between the first and second IST visits.
(Day 3-IST Visit 2) and IST Visit 3, scheduled 3-7 days apart.

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Investigador principal: David King, BSc, MSc, PhD, Heriot-Watt University

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

20 de julho de 2026

Conclusão Primária (Estimado)

30 de setembro de 2026

Conclusão do estudo (Estimado)

30 de outubro de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

8 de setembro de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

14 de setembro de 2026

Primeira postagem (Real)

18 de setembro de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

18 de setembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

14 de setembro de 2026

Última verificação

1 de setembro de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Descrição do plano IPD

No individual participant data will be shared publicly. The study will report findings using aggregated and de-identified data. Individual participant data will be retained securely by the research team in accordance with Heriot-Watt University research governance and data protection requirements.

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever