Esophageal Pressure and Cardiac Output

20 de novembro de 2026 atualizado por: Jun-Young Park, Asan Medical Center

Dynamic Concordance Analysis Between Cardiac Oscillation Waveform-derived Esophageal Pressure and Cardiac Output Parameters: A Prospective Observational Study

This prospective observational study aims to determine whether a pressure signal recorded through a standard esophageal temperature probe can track changes in cardiac output during general anesthesia.

During surgery, anesthesiologists need to keep the heart adequately filled (preload) to maintain blood flow to vital organs. Central venous pressure, the traditional bedside measure, reflects intravascular volume poorly. Pulmonary capillary wedge pressure, which estimates left atrial pressure, requires a pulmonary artery catheter, an invasive device that is now rarely used. Dynamic indices such as stroke volume variation and pulse pressure variation are reliable only under strict conditions, such as controlled ventilation with an adequate tidal volume, absence of spontaneous breathing, and a regular heart rhythm.

The esophagus lies directly behind the left atrium. When an esophageal probe is filled with saline and connected to a pressure transducer, small pulsatile "cardiac oscillation" waves can be recorded at a certain depth. The investigators hypothesize that this signal reflects pressure changes transmitted from the left atrium and therefore carries real-time information about cardiac filling and output.

Forty adult patients (aged 20 to 79 years, ASA physical status I to III) scheduled for surgery under general anesthesia with invasive arterial pressure and arterial pressure-based cardiac output monitoring will be enrolled after written informed consent. After induction of anesthesia and tracheal intubation, an 18 Fr esophageal temperature probe, which is routinely used for temperature monitoring, will be filled with 7 to 8 mL of sterile saline, connected to a pressure transducer, and advanced until a clear and stable cardiac oscillation waveform with an amplitude of at least 0.5 to 1.0 mmHg is identified. Anesthesia and surgical care will follow standard practice, and the study will not change clinical management. Arterial pressure, heart rate, esophageal pressure, cardiac output, cardiac index, stroke volume, stroke volume index, stroke volume variation, pulse pressure variation, airway pressure, and positive end-expiratory pressure will be recorded continuously and analyzed around hemodynamic events such as fluid administration, bleeding, and vascular clamping.

The primary outcome is the concordance rate between the percentage changes in stroke volume index and in cardiac oscillation-derived esophageal pressure during these events, assessed by four-quadrant plot analysis after excluding small changes (less than 15%). Secondary outcomes are trending ability assessed by polar plot analysis (angular error), agreement between the percentage changes of the two measures assessed by Bland-Altman analysis (percentage error), and the ability of esophageal pressure changes to predict fluid responsiveness (an increase in stroke volume of more than 15%) assessed by receiver operating characteristic curve analysis.

If the esophageal pressure signal reliably tracks changes in cardiac output, it could offer a simple hemodynamic monitoring method that uses equipment already in routine use during general anesthesia, without additional invasive devices.

Visão geral do estudo

Status

Ainda não está recrutando

Tipo de estudo

Observacional

Inscrição (Estimado)

40

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

  • Nome: Jun-Young Park, MD, PhD
  • Número de telefone: 82-2-3010-3868
  • E-mail: parkjy@amc.seoul.kr

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

20 anos a 79 anos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Método de amostragem

Amostra Não Probabilística

População do estudo

Adult patients aged 20 to 79 years with ASA physical status I to III who are scheduled for surgery under general anesthesia with invasive arterial pressure and arterial pressure-based cardiac output monitoring as part of routine clinical care at Asan Medical Center, Seoul, Republic of Korea. Eligible patients will be approached consecutively before surgery, and those who provide written informed consent will be enrolled.

Descrição

Inclusion Criteria:

  • Adult patients scheduled for surgery under general anesthesia with invasive arterial pressure and arterial pressure-based cardiac output monitoring
  • Age 20 years or older and younger than 80 years
  • American Society of Anesthesiologists (ASA) physical status I to III
  • Voluntary written informed consent to participate in the study

Exclusion Criteria:

  • Esophageal disease, such as esophageal varices, esophageal diverticulum, esophageal stricture, or esophageal cancer
  • Anatomical variation in the relative position of the esophagus and heart, such as severe chest wall deformity
  • Significant cardiac functional or structural abnormality on echocardiography, including left ventricular ejection fraction less than 40%, moderate or greater mitral or aortic valve disease, or intracardiac shunt
  • Persistent atrial fibrillation or frequent premature ventricular contractions
  • Need for repeated changes in ventilator settings, such as positive end-expiratory pressure or tidal volume, during surgery
  • Surgery requiring the lateral decubitus or prone position
  • Need for insertion of another device into the esophagus, such as a transesophageal echocardiography probe
  • Body mass index of 40 kg/m2 or greater, or less than 17.5 kg/m2
  • Refusal to participate

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Modelos de observação: COHORT
  • Perspectivas de Tempo: PROSPECTIVE

Coortes e Intervenções

Grupo / Coorte
Adults under general anesthesia with cardiac output monitoring

Adult patients aged 20 to 79 years (ASA physical status I to III) undergoing surgery under general anesthesia with invasive arterial pressure and arterial pressure-based cardiac output monitoring as part of routine care. After tracheal intubation, an 18 Fr esophageal temperature probe routinely used for temperature monitoring is filled with 7 to 8 mL of sterile saline, connected to a pressure transducer, and positioned where a stable cardiac oscillation waveform (amplitude of at least 0.5 to 1.0 mmHg) is observed. Cardiac oscillation-derived esophageal pressure and hemodynamic variables (stroke volume index, cardiac index, arterial pressure, stroke volume variation, pulse pressure variation) are recorded continuously during hemodynamic events such as fluid administration, bleeding, and vascular clamping. Anesthetic and surgical management follow standard practice and are not altered by the study.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Concordance rate between changes in stroke volume index and cardiac oscillation-derived esophageal pressure
Prazo: Intraoperative: immediately before and 1 minute after the end of each hemodynamic event, from probe placement after tracheal intubation to the end of surgery

For each intraoperative hemodynamic event (e.g., fluid administration, bleeding, vascular clamping), the percentage change from the pre-event value to the post-event value is calculated for stroke volume index (SVI), measured by arterial pressure-based cardiac output monitoring, and for cardiac oscillation-derived esophageal pressure, measured through a saline-filled esophageal temperature probe. Paired changes are plotted on a four-quadrant plot. After excluding pairs with a change of less than 15% (exclusion zone), the concordance rate is calculated as the percentage of paired changes in which both measures change in the same direction (both increase or both decrease).

Intraoperative: immediately before and 1 minute after the end of each hemodynamic event, from probe placement after tracheal intubation to the end of surgery

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Angular error of trending ability assessed by polar plot analysis
Prazo: Intraoperative: immediately before and 1 minute after the end of each hemodynamic event, from probe placement after tracheal intubation to the end of surgery

Paired percentage changes in stroke volume index and cardiac oscillation-derived esophageal pressure during hemodynamic events are converted into polar coordinates. The mean angular bias (degrees) and the radial limits of agreement (degrees) are calculated to quantify the trending ability of esophageal pressure relative to stroke volume index. Pairs within the 15% exclusion zone are excluded.

Intraoperative: immediately before and 1 minute after the end of each hemodynamic event, from probe placement after tracheal intubation to the end of surgery
Percentage error between changes in stroke volume index and esophageal pressure assessed by Bland-Altman analysis
Prazo: Intraoperative: immediately before and 1 minute after the end of each hemodynamic event, from probe placement after tracheal intubation to the end of surgery

Because stroke volume index and esophageal pressure have different units, agreement is assessed using the percentage changes of each measure during hemodynamic events. Bland-Altman analysis is performed to calculate the bias and 95% limits of agreement between the paired percentage changes, and the percentage error is derived from these values.

Intraoperative: immediately before and 1 minute after the end of each hemodynamic event, from probe placement after tracheal intubation to the end of surgery
Area under the receiver operating characteristic curve (AUC) of esophageal pressure change for predicting fluid responsiveness
Prazo: Intraoperative: immediately before and 1 minute after the end of each fluid administration, from probe placement after tracheal intubation to the end of surgery

Fluid responsiveness is defined as an increase in stroke volume of more than 15% after fluid administration. The ability of the percentage change in cardiac oscillation-derived esophageal pressure to discriminate fluid responders from non-responders is assessed by receiver operating characteristic curve analysis. The AUC with its 95% confidence interval and the optimal cut-off value (Youden index) are reported.

Intraoperative: immediately before and 1 minute after the end of each fluid administration, from probe placement after tracheal intubation to the end of surgery

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

12 de dezembro de 2026

Conclusão Primária (Estimado)

1 de julho de 2027

Conclusão do estudo (Estimado)

1 de julho de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

20 de novembro de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

20 de novembro de 2026

Primeira postagem (Real)

27 de novembro de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

27 de novembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

20 de novembro de 2026

Última verificação

1 de novembro de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • Eso_pr_CO

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .