Comparison of Three Methods of Taking Temperatures in the Well Baby Nursery

28 april 2011 uppdaterad av: Christiana Care Health Services

Comparison of Temporal Artery, Axillary, and Rectal Temperatures in Newborn Patients in the Well Baby Nursery.

Body temperature measurement is one of the standard vital sign measurements in newborn babies in order assess their health status. Temperatures are taken on a regular basis throughout the newborn's stay on the well-baby floor. A temperature that is elevated above the normal range for age or depressed below the normal range for age may be a sign of illness in a newborn. There are many methods that may be used to record this temperature. Traditionally, axillary (under the arm) and rectal (in the rectum) sites have been used. Recently, a new method of temperature measurement has become available. Temporal artery thermometers are a non-invasive method to measure the baby's temperature by means of a light that is shone on the forehead that can read your baby's temperature quickly. It is not clear whether this method is accurate in the newborn period.

The purpose of this study is to evaluate the accuracy of temporal artery temperature measurement. This will be achieved by observing the axillary measurement, rectal temperature measurement, and temporal artery temperature measurement taken at approximately the same time in each infant. These measurements will be compared to each other to determine if temporal artery thermometry is as reliable a measurement as rectal and / or axillary temperature measurements.

We plan to compare

Hypothesis: Temporal artery thermometry of the immediate newborn infant is an accurate measurement of temperature in this age group.

Studieöversikt

Status

Avslutad

Betingelser

Studietyp

Interventionell

Inskrivning (Faktisk)

104

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

    • Delaware
      • Newark, Delaware, Förenta staterna, 19713
        • Christiana Care Health Systems

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

Inte äldre än 1 dag (Barn)

Tar emot friska volontärer

Ja

Kön som är behöriga för studier

Allt

Beskrivning

Inclusion Criteria:

  • term newborns >/= 37 weeks gestational age
  • late preterm infants >/= 35 weeks gestational age
  • admitted to the well baby nursery following delivery
  • < 24 hours of age

Exclusion Criteria:

  • Infants < 35 weeks gestational age
  • Infants currently under a radiant warmer or who have been under a radiant warmer < 1 hour prior to temperature measurement.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Tilldelning: Icke-randomiserad
  • Interventionsmodell: Enskild gruppuppgift

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Övrig: TAT vs. RT
This arm is comparing the Temporal Artery Thermometer (TAT) temperature to the Rectal Temperature (RT).
Newborn infants had a temporal artery temperature taken within a few minutes of the axillary and rectal temperatures. The axillary and rectal temperatures are taken via methods which are standard of care.
Andra namn:
  • Exergen TAT-5000 TemporalScanner Exergen Corp; Watertown, MA)
Övrig: TAT vs. AT
This arm is comparing the Temporal Artery Thermometer (TAT) temperature to the Axillary Temperature (AT).
Newborn infants had a temporal artery temperature taken within a few minutes of the axillary and rectal temperatures. The axillary and rectal temperatures are taken via methods which are standard of care.
Andra namn:
  • Exergen TAT-5000 TemporalScanner Exergen Corp; Watertown, MA)

Vad mäter studien?

Primära resultatmått

Resultatmått
Tidsram
Accuracy of temporal artery temperature compared to rectal and axillary temperature measurements.
Tidsram: All temperatures will be taken within 5 minutes of each other
All temperatures will be taken within 5 minutes of each other

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Utredare

  • Huvudutredare: Michael F. Bruno, MD, Christiana Care Health Services

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart

1 oktober 2008

Primärt slutförande (Faktisk)

1 augusti 2009

Avslutad studie (Faktisk)

1 augusti 2009

Studieregistreringsdatum

Först inskickad

29 september 2008

Först inskickad som uppfyllde QC-kriterierna

29 september 2008

Första postat (Uppskatta)

30 september 2008

Uppdateringar av studier

Senaste uppdatering publicerad (Uppskatta)

29 april 2011

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

28 april 2011

Senast verifierad

1 april 2011

Mer information

Termer relaterade till denna studie

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera