- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT07686003
Flow Dynamics During Simulated Hemostasis at the Proximal and Distal Radial Arteries (FLOW-PRADA)
Flow Dynamics During Simulated Hemostasis at the Proximal and Distal Radial Arteries: The FLOW-PRADA Study
Transradial access (TRA) has been widely adopted for coronary angiography and percutaneous coronary intervention, as it has been shown to significantly reduce bleeding complications, vascular complications, and mortality compared with transfemoral access (TFA). Based on this evidence, recent international guidelines recommend TRA as the preferred access strategy.
Radial artery occlusion (RAO), a potential complication following TRA, is often clinically silent and therefore underestimated. However, RAO has important clinical implications, particularly in patients who may require repeated coronary procedures, those in whom the radial artery may be used as a conduit for coronary artery bypass grafting, or patients with chronic kidney disease requiring arteriovenous fistula formation. Therefore, maintaining radial artery patency after the procedure is of considerable clinical importance.
Distal radial access (DRA), which utilizes the radial artery at the anatomical snuffbox, is a relatively recent approach. Multiple studies and meta-analyses have demonstrated that DRA provides comparable procedural success rates to TRA while significantly reducing bleeding complications and the incidence of RAO. Notably, despite the generally accepted association between smaller vessel diameter and higher risk of occlusion, DRA paradoxically shows a lower incidence of RAO. The underlying mechanism for this observation remains incompletely understood.
Sgueglia et al. evaluated peak systolic velocity using Doppler ultrasonography under conditions of arterial compression and reported that antegrade blood flow was better preserved during distal radial artery compression compared with proximal radial artery compression. This finding suggests a potential mechanistic explanation for the lower incidence of RAO observed with DRA.
However, there is a paucity of studies that systematically evaluate hemodynamic changes under simulated real-world hemostatic conditions at both proximal and distal radial arteries.
Therefore, the aim of this study is to quantitatively assess hemodynamic changes induced by simulated occlusive hemostasis at the proximal and distal radial arteries using Doppler ultrasonography, and to elucidate the mechanisms underlying the lower incidence of RAO observed with DRA.
Studieöversikt
Status
Betingelser
Intervention / Behandling
Studietyp
Inskrivning (Beräknad)
Kontakter och platser
Studiekontakt
- Namn: Jun-Won Lee, MD, PhD
- E-post: ljwcardio@yonsei.ac.kr
Studera Kontakt Backup
- Namn: Jung-Woo Son
- Telefonnummer: +82-33-741-0910
- E-post: soneycar@gmail.com
Studieorter
-
-
Gangwon-do
-
Wŏnju, Gangwon-do, Sydkorea, 26426
- Wonju Severance Christian Hospital
-
Kontakt:
- Jung-Woo Son, MD
- Telefonnummer: +82-33-741-0920
- E-post: soneycar@gmail.com
-
Kontakt:
- Jun-Won Lee, MD, PhD
- Telefonnummer: +82-33-741-0920
- E-post: ljwcardio@yonsei.ac.kr
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
- Barn
- Vuxen
- Äldre vuxen
Tar emot friska volontärer
Testmetod
Studera befolkning
Beskrivning
Inclusion Criteria:
A. Adults aged ≥19 years B. Patients scheduled for coronary angiography due to atypical chest pain, stable angina, or acute coronary syndrome C. Patients undergoing transthoracic echocardiography for assessment of cardiac function prior to coronary angiography D. Palpable proximal and distal radial arteries
Exclusion Criteria:
A. Cardiogenic shock B. Patients who have undergone coronary angiography via distal radial access prior to echocardiographic evaluation C. Refusal or inability to provide informed consent D. Presence of an ipsilateral arteriovenous fistula E. Pregnant or breastfeeding women
Studieplan
Hur är studien utformad?
Designdetaljer
Kohorter och interventioner
Grupp / Kohort |
Intervention / Behandling |
|---|---|
|
Patent hemostasis of distal radial artery
Patent hemostasis of distal radial artery using TR band
|
Simulated patent hemostasis using air-filled TR band
|
|
Patent hemostasis of proximal radial artery
Patent hemostasis of proximal radial artery using TR band
|
Simulated patent hemostasis using air-filled TR band
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Difference in end-diastolic velocity
Tidsram: Periprocedural
|
Difference in end-diastolic velocity between proximal and distal radial arteries during patent hemostasis by Doppler ultrasound
|
Periprocedural
|
Sekundära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Flow preservation ratio
Tidsram: Periprocedural
|
Flow preservation ratio in proximal and distal radial arteries
|
Periprocedural
|
|
Blood flow volume
Tidsram: Periprocedural
|
Blood flow volume in proximal and distal radial arteries
|
Periprocedural
|
|
Flow volume per beat
Tidsram: Periprocedural
|
Flow volume per beat in proximal and distal radial arteries
|
Periprocedural
|
|
Pulsatility index
Tidsram: Periprocedural
|
Pulsatility index in proximal and distal radial arteries
|
Periprocedural
|
|
Resistance index
Tidsram: Periprocedural
|
Resistance index in proximal and distal radial arteries
|
Periprocedural
|
|
Peak systolic velocity
Tidsram: Periprocedural
|
Peak systolic velocity in proximal and distal radial arteries
|
Periprocedural
|
|
Velocity time integral
Tidsram: Periprocedural
|
Velocity time integral in proximal and distal radial arteries
|
Periprocedural
|
|
Radial artery occlusion
Tidsram: up to 1 month
|
Radial artery occlusion
|
up to 1 month
|
Samarbetspartners och utredare
Samarbetspartners
Utredare
- Huvudutredare: Jung-Woo Son, Yonsei University Wonju College of Medicine, Wonju Severance Christian Hospital
Studieavstämningsdatum
Studera stora datum
Studiestart (Beräknad)
Primärt slutförande (Beräknad)
Avslutad studie (Beräknad)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Nyckelord
Andra studie-ID-nummer
- CR326050
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Studerar en amerikansk FDA-reglerad produktprodukt
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .