此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Is There Increased Polyethylene Wear and Increased Periprosthetic Bone Loss in Femur in Reverse Hybrid Technique Compared With Conventional Cemented Technique in Total Hip Replacement?

2011年7月3日 更新者:Ullevaal University Hospital

Total hip replacement is a very cost effective procedure to enhance life quality in a group of patients. In the period 2000-2004 7-8000 procedures were preformed, 13% were revisions (1). Historically, many different principles have been used from the first resurfacings to cemented and uncemented total hip replacements as we know them today. In 2000, 28 different femoral stems and 26 different acetabular components were in regular use in Norway. There are several well-documented cemented acetabular components, but no such uncemented cup. On the femoral side there are several well-documented stems both cemented and uncemented. (2).

From the late 1990's a reverse hybrid (uncemented stem and cemented cup) is being more frequently used. In 2004 a total of 276 reverse hybrid hips were done and the trend is increasing. (1). This technique is solely based on experience and the fact that one combines the better of two principles (cemented and uncemented). There is no scientific evidence that this technique is as good or better than a cemented THR.

One of the potential problems with hydroxyapatite coated components is that it is suspected that it may increase wear due to the particle theory. (3,4). There are no prospective randomised controlled RSA and DXA studies that conclude on this matter. This is such a study and our hypothesis is that there is no difference in wear or osteolysis between the methods.

研究概览

研究类型

介入性

阶段

  • 不适用

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

不超过 75年 (孩子、成人、年长者)

接受健康志愿者

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Osteoarthritis
  • Indication for THR

Exclusion Criteria:

  • Significant anatomical abnormalities
  • Rheumatoid artheritis, dysplasia, fracture sequela

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:基础科学
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:无(打开标签)

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 学习椅:Lars Nordsletten, professor, MD, Ph.D、Ullevål University Hospital, N-0407 Oslo
  • 首席研究员:Einar Lindalen, MD、Lovisenberg Hospital, N- 0440 Oslo

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2022年12月7日

初级完成

2022年12月7日

研究完成

2022年12月7日

研究注册日期

首次提交

2007年9月6日

首先提交符合 QC 标准的

2007年9月6日

首次发布 (估计)

2007年9月10日

研究记录更新

最后更新发布 (估计)

2011年7月6日

上次提交的符合 QC 标准的更新

2011年7月3日

最后验证

2007年9月1日

更多信息

与本研究相关的术语

其他研究编号

  • Reverse hybrid vs cemented THR

药物和器械信息、研究文件

研究美国 FDA 监管的药品

研究美国 FDA 监管的设备产品

在美国制造并从美国出口的产品

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.