- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT00526539
Is There Increased Polyethylene Wear and Increased Periprosthetic Bone Loss in Femur in Reverse Hybrid Technique Compared With Conventional Cemented Technique in Total Hip Replacement?
Total hip replacement is a very cost effective procedure to enhance life quality in a group of patients. In the period 2000-2004 7-8000 procedures were preformed, 13% were revisions (1). Historically, many different principles have been used from the first resurfacings to cemented and uncemented total hip replacements as we know them today. In 2000, 28 different femoral stems and 26 different acetabular components were in regular use in Norway. There are several well-documented cemented acetabular components, but no such uncemented cup. On the femoral side there are several well-documented stems both cemented and uncemented. (2).
From the late 1990's a reverse hybrid (uncemented stem and cemented cup) is being more frequently used. In 2004 a total of 276 reverse hybrid hips were done and the trend is increasing. (1). This technique is solely based on experience and the fact that one combines the better of two principles (cemented and uncemented). There is no scientific evidence that this technique is as good or better than a cemented THR.
One of the potential problems with hydroxyapatite coated components is that it is suspected that it may increase wear due to the particle theory. (3,4). There are no prospective randomised controlled RSA and DXA studies that conclude on this matter. This is such a study and our hypothesis is that there is no difference in wear or osteolysis between the methods.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Tipo de estudio
Fase
- No aplica
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Osteoarthritis
- Indication for THR
Exclusion Criteria:
- Significant anatomical abnormalities
- Rheumatoid artheritis, dysplasia, fracture sequela
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Ciencia básica
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Colaboradores e Investigadores
Patrocinador
Investigadores
- Silla de estudio: Lars Nordsletten, professor, MD, Ph.D, Ullevål University Hospital, N-0407 Oslo
- Investigador principal: Einar Lindalen, MD, Lovisenberg Hospital, N- 0440 Oslo
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- Reverse hybrid vs cemented THR
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .
Ensayos clínicos sobre Total hip replacement, Spectron and Taperloc
-