A Pilot Study to Assess the Ability of Non-invasive Bio-impedance Cardiac Monitoring to Detect and Trend Hemodynamic Variables During Dexmedetomidine (DEX) Sedation in Children for Radiology Procedures

The aim of the study is to investigate the use of a new FDA-approved non-invasive bio-impedance cardiac monitor, ICON, to detect hemodynamic effects during sedation in children undergoing radiology procedures. The purpose of the study is to determine the ability of the ICON monitor to identify the anticipated and documented hemodynamic changes in children which occur in response to Dexmedetomidine sedation. The investigators postulate that if the ICON device can trend hemodynamic changes, if any, during dexmedetomidine (DEX) sedation in children the investigators can delineate changes in cardiac output, stroke volume, and systemic vascular resistance associated with observed changes in heart rate and blood pressure.

研究概览

地位

完全的

研究类型

观察性的

注册 (实际的)

17

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Massachusetts
      • Boston、Massachusetts、美国、02115
        • Children Hospital Boston

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

1个月 至 18年 (孩子、成人)

接受健康志愿者

不

有资格学习的性别

全部

取样方法

非概率样本

研究人群

All pediatric patients (1 month to 18 years of age) eligible for Radiology Sedation Service for CT scan and Nuclear Medicine Scan procedure who agrees to participate in the study will have their vital signs and ICON measurements recorded continuously pre-sedation, during sedation and through recovery until discharge.

描述

Inclusion Criteria:

  • All pediatric patients (1 month to 18 years of age)
  • Eligible for Radiology Sedation Service for CT scan and Nuclear Medicine
  • Scan procedure

Exclusion Criteria:

  • Pacemakers and Vagus Nerve Stimulator
  • Mitral or Aorta Valve Dysfunction
  • Dextrocardia
  • Second or Third degree heart block
  • Current diagnosis of Cardiac, Pulmonary, Hepatic or Renal Failure
  • Current diagnosis of pulmonary masses/tumor/pleural effusions/pneumonia/edema
  • Pericardial effusion
  • Concomitant use of hypertension medications including ACE inhibitors, beta receptor and calcium channel blockers.
  • Large Implanted Metallic Devices (including orthodontic braces, spine rods, plates and screws)
  • Allergy to device electrodes

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
Children sedated by DEX
All pediatric patients (1 month to 18 years of age) eligible for Radiology Sedation Service for CT scan and Nuclear Medicine Scan procedure.

研究衡量的是什么?

主要结果指标

结果测量
大体时间
The primary aim is to ascertain if a decrease in heart rate (HR) with intravenous (IV) DEX is associated with a change in trend of cardiac output (CO) as measured by the ICON device.
大体时间:pre-, during, and post sedation
pre-, during, and post sedation

次要结果测量

结果测量
大体时间
To determine the cardiac parameters provided by the ICON device during changes in blood pressure.
大体时间:pre-, during and post sedation
pre-, during and post sedation

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Jackson Wong, MD、Children Hospital Boston

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2009年9月1日

初级完成 (实际的)

2011年9月1日

研究完成 (实际的)

2011年9月1日

研究注册日期

首次提交

2009年10月23日

首先提交符合 QC 标准的

2009年10月23日

首次发布 (估计)

2009年10月26日

研究记录更新

最后更新发布 (估计)

2017年1月5日

上次提交的符合 QC 标准的更新

2017年1月4日

最后验证

2011年6月1日

更多信息

与本研究相关的术语

其他研究编号

  • 09-03-0130

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅