此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Observational Study to Assess Oxygen Saturation Predictive Power Related to Intradialytic Acute Hypotension (SOGLIA)

2012年12月24日 更新者:Antonio Santoro、IRCCS Azienda Ospedaliero-Universitaria di Bologna

Italian Group of Study on the Role of Oxygen Saturation as a Potential Surrogate Marker of Intradialytic Cardiovascular Instability

The aim of the present work was to analyze the short-term variability of SO2 during hemodialysis in sessions with and without hypotension to correlate the SO2 variability to hemodynamic instability.

研究概览

详细说明

During the last 40 years a lot has been achieved in dialysis regarding both monitors safety and membranes overall performances Anyway, intradialytic symptoms still remain a major concern for nephrologists: in particular, hypotension is the most frequent [1].

Intradialytic hemodynamic monitoring systems have been developed to have continuous surveillance of the main hemodynamic variables (heart rate, body temperature, blood pressure itself, cardiac output, ecc…).

In a second moment, the further evolution was towards the retroactive control systems, to force some of the variables involved in the genesis of the hemodynamic stability, along a pre-determined, ideal, trend. In this view, various bio-feedback mechanisms have been proposes along the years, for example, to tackle hypovolemia-related hypotension. Their scientific rationale is the control of either blood volume or directly natremia, in order to pilot plasma refilling towards the vascular compartment [2].

Despite the great achievements obtained, the forecasting of acute hypotension during hemodialysis still remains a complex problem, likely involving more than one variable.

SO2 can be considered an indirect expression of the hemodynamic stability. Moreover, in dialysis, it has always been regarded as a bio-compatibility marker for membranes [3]. Nowadays, SO2 changes during dialysis are easy to measure with a fully, non-invasive sensor assembled on the arterial line.

We planned this study to analyze on a large number of sessions the short-term variability of SO2 during hemodialysis in relationship with hemodynamic tolerance.

研究类型

观察性的

注册 (实际的)

51

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Bologna、意大利、40057
        • Azienda Ospedaliero-Universitaria "S. Orsola-Malpighi", Nephrology, Dialysis and Hypertension dpt.

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 85年 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

取样方法

非概率样本

研究人群

ESRD patients on RRT with a recent clinical history of acute intradialytic hypotension.

描述

Inclusion Criteria:

  • Dialysis vintage > 6 months
  • Well functioning arterovenous fistula or central venous catheter
  • thrice weekly HD treatment schedule
  • Acute hypotensions in the last month before study start > 20% of sessions

Exclusion Criteria:

  • Mental illness
  • life expectancy < 6 months
  • any profiling and/or biofeedback strategies routinely prescribed

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
Hypotension-prone patients
The study group included all patients treated with standard HD prone to acute intradialytic hypotension.
Hemox optical sensor equips the dialysis monitors used during this trial. It is able to measure continuously, on arterial blood line, oxygen saturation, hematocrit and blood volume reduction.
其他名称:
  • Hemox

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
SO2 short-term variability predictive power
大体时间:3 months

SO2 short term variability predictive power was assessed by means of common clinical tests indexes:

sensitivity (number of sessions with effective hypotension correctly classified using SO2 standard deviation analysis)

specificity (number of sessions without hypotension correctly classified using SO2 standard deviation analysis)

3 months

次要结果测量

结果测量
措施说明
大体时间
Central venous catheters subgroup analysis
大体时间:3 months
This analysis was performed, according to the method described in the Primary Outcome section, only on the group of sessions in which a central catheter was used as vascular access.
3 months

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Antonio Santoro, MD、Azienda ospedaliera universitaria "S. Orsola-Malpighi", Bologna, Italy

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2011年1月1日

初级完成 (实际的)

2011年9月1日

研究完成 (实际的)

2012年8月1日

研究注册日期

首次提交

2012年12月24日

首先提交符合 QC 标准的

2012年12月24日

首次发布 (估计)

2013年1月3日

研究记录更新

最后更新发布 (估计)

2013年1月3日

上次提交的符合 QC 标准的更新

2012年12月24日

最后验证

2012年12月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • CRC-MAL 01

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅