4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation (GCC 1210)
2020年3月16日 更新者:Department of Radiation Oncology、University of Maryland, Baltimore
Individually Optimized Contrast-Enhancement 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation
The primary objective is to study the feasibility and efficacy of individually optimized CE 4D-CT for PDA in radiotherapy simulation.
研究概览
详细说明
Compared with current clinical practice, the individually optimized CE 4D-CT can potentially provide much improved tumor-to-parenchyma conspicuity of pancreatic adenocarcinoma.
This will help the radiation oncologists or radiologists to contour the tumor with higher precision and confidence, and compute the tumor volume and tumor motion more accurately.
研究类型
观察性的
注册 (实际的)
14
联系人和位置
本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。
学习地点
-
-
Maryland
-
Baltimore、Maryland、美国、21201
- Ummc Msgcc
-
-
参与标准
研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。
资格标准
适合学习的年龄
18年 及以上 (成人、年长者)
接受健康志愿者
不
有资格学习的性别
全部
取样方法
非概率样本
研究人群
GI/GU multi-d clinic
描述
Inclusion Criteria:
- Patients 18 years old or older
- Patients with PDA who have not had surgical removal of their tumor and who are planned for treatment with radiotherapy in the Radiation Oncology Department at the University of Maryland.
- Patients who have signed the contrast consent form and have been recommended by physicians to have contrast-enhanced CT scans.
- Patients who have signed the consent form for this study
Exclusion Criteria:
- Pregnant or breast-feeding women.
- Patients with severely decreased renal function19-21.
- Patients with known severe allergic reactions to contrast.
- Patients who have difficulty lying flat on their back for extended periods of time.
- Patients with breaths per minute (BPM) rate less than 10, due to the limitation of 4D-CT image reconstruction software.
学习计划
本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
All enrolled patients
Contrast-enhanced 4D computed tomography
|
All enrolled patients each underwent three CT scans: a 4DCT immediately following a contrast-enhanced 3DCT and an individually optimized contrast-enhanced 4DCT.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Individually Optimized Contrast-enhanced 4DCT for Radiotherapy Simulation
大体时间:1 year
|
Image quality (anatomic details, motion artifacts, beam hardening and enhancement of pancreatic tissue and tumor were scored from 1 to 5, with 1 being very poor and 5 being excellent), CT number of pancreas and tumor, tumor-to-pancreas contrast, image noise and contrast-to-noise ration (CNR) were compared among contrast-enhanced (CE) 4DCT, CE 3DCT and 4DCT without contrast enhancement.
|
1 year
|
合作者和调查者
在这里您可以找到参与这项研究的人员和组织。
调查人员
- 首席研究员:Wei Lu, Ph. D., DABR、Ummc Msgcc
- 首席研究员:Hao H Zhang, Ph. D.、UMMC
研究记录日期
这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。
研究主要日期
学习开始
2013年7月1日
初级完成 (实际的)
2014年10月1日
研究完成 (实际的)
2014年10月1日
研究注册日期
首次提交
2013年1月2日
首先提交符合 QC 标准的
2013年1月7日
首次发布 (估计)
2013年1月9日
研究记录更新
最后更新发布 (实际的)
2020年3月27日
上次提交的符合 QC 标准的更新
2020年3月16日
最后验证
2020年3月1日
更多信息
与本研究相关的术语
其他研究编号
- HP-00052534
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.