此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Minimal Occlusive Pressure With Cuffed ETT: the Effect of Size on Intracuff Pressure

2016年9月12日 更新者:Senthil G. Krishna
The purpose of this current study is to evaluate whether the size of the endotracheal tube (ETT) that is used impacts the intracuff pressure that occurs when the airway is sealed. If there is excessive pressure in the cuff of a smaller ETT when it is inflated, there may be inherent risks associated with the use of a cuffed endotracheal tube that is less than the appropriate size. The investigators believe that the size of the tube chosen has an impact on the characteristics of the inflated cuff and hence the intracuff pressure and the sealing pressure are variable.

研究概览

研究类型

介入性

注册 (实际的)

100

阶段

  • 不适用

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

4年 至 8年 (孩子)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Patients requiring intubation with an ETT for a surgical procedure.
  • Children ages 4 to 8 years old.
  • Surgical procedure lasting less than 60 minutes.

Exclusion Criteria:

  • Patients undergoing a surgical procedure that is anticipated to last longer than 60 minutes.
  • Patients that are known or anticipated to have a difficult airway.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:诊断
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
有源比较器:Standard ETT size
Their tracheas will be intubated with an appropriately sized ETT using the standard formula. The cuff will be inflated to achieve a seal by the air-leak test when holding CPAP of 20 cmH2O and the intracuff pressure will be measured using a manometer.
实验性的:ETT one size smaller
Their tracheas will be intubated with an ETT that is one size smaller (instead of a 5.0 ETT, we would use a 4.0 ETT). The cuff will be inflated to achieve a seal by the air-leak test when holding CPAP of 20 cmH2O and the intracuff pressure will be measured using a manometer.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Intracuff pressure
大体时间:intraoperative
Our goal is to measure the intracuff pressure that is achieved when the airway is sealed with an ETT based on the formula (ETT=(age/4)+3) and compare it to the intracuff pressure when the airway is sealed with an ETT that is 1 size smaller (4.0 mm instead of 5.0 mm).
intraoperative

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2014年10月1日

初级完成 (实际的)

2016年7月1日

研究完成 (实际的)

2016年7月1日

研究注册日期

首次提交

2015年2月24日

首先提交符合 QC 标准的

2015年2月27日

首次发布 (估计)

2015年3月3日

研究记录更新

最后更新发布 (估计)

2016年9月13日

上次提交的符合 QC 标准的更新

2016年9月12日

最后验证

2016年8月1日

更多信息

与本研究相关的术语

其他研究编号

  • IRB14-00521

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅