此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Detecting a Volume Deficit During Spontaneous Breathing

2015年9月12日 更新者:Michael Dahl、Aalborg University Hospital

Detecting a Central Volume Deficit in Spontaneous Breathing Healthy Volunteers by Systolic Blood Pressure Variation

13 healthy volunteers (4 females) were tilted 45° head-up while breathing through a facemask fitted with an inspiratory and expiratory resistor. A brachial arterial catheter was used to measure blood pressure and thus systolic pressure variation and pulse contour analysis determined stroke volume and thereby cardiac output in order to detect a central volume deficit.

研究概览

地位

完全的

条件

详细说明

Thirteen healthy volunteers (4 women) at an age of 25 years (range 18-36) were recruited through www.forsøgsperson.dk.

The volunteers were placed on a tilt table and provided with a facemask with an opening of 30-33 mm. A Hook ring was fitted with an inspiratory resistor, an expiratory resistor, a combination of the two resistors, or with no resistance and each resistor provides a 7.5 cmH2O threshold resistance. Each resistor was applied for two minutes with variables obtained in the last minute. The table was then tilted 45° head-up to accumulating blood in the legs and therefore a reduction in the central blood volume. Conversely, 20° head-down tilt was used to expand the central blood volume. For each volunteer measurements with the four respiratory interventions was randomized, whereas the tilt table position was in fixed order: supine, head-up tilt, and head-down tilt.

Three-lead ECG recorded heart rate. A 20 G arterial catheter was placed in the brachial artery of the non-dominant arm and connected to a transducer for reading of blood pressure and stroke volume variation (Vigileo-Flotrac™, version 1.07, Edwards Lifesciences, Nyon, Switzerland). Also SV and CO variation and the arterial pressure curve were recorded for subsequent determination of arterial pressure variations. Additionally, a catheter was placed via a brachial vein to the superior caval vein for recording of central venous pressure and SvO2. While the subjects were breathing spontaneously, the respiratory rate was measured by capnography and peripheral oxygen saturation by fingerprobe.

Variation in the arterial pulse pressure (PPV) was 100 x ((PPmax - PPmin) / ((PPmax + PPmin)/2)), where PPmax and PPmin is the maximal and minimal difference between systolic and diastolic pressure during the respiratory cycle, respectively. By the same formula systolic pressure variation (SPV) was calculated.

研究类型

介入性

注册 (实际的)

13

阶段

  • 不适用

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • healthy volunteers

Exclusion Criteria:

  • pregnancy
  • lactating
  • any regular or acute use of medicine

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Systolic pressure variation (SPV)
大体时间:Two minutes
Relative difference between systolic blood pressure during inspiration and expiration. Meassured in percent.
Two minutes

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2011年8月1日

初级完成 (实际的)

2011年8月1日

研究完成 (实际的)

2011年8月1日

研究注册日期

首次提交

2015年9月10日

首先提交符合 QC 标准的

2015年9月12日

首次发布 (估计)

2015年9月15日

研究记录更新

最后更新发布 (估计)

2015年9月15日

上次提交的符合 QC 标准的更新

2015年9月12日

最后验证

2015年9月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • H-4-2010-110-SPV

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅