Identification of Epidural Space Description of New Technique
Introduction Several attempts have been made to improve or facilitate epidural space detection beside conventional loss of resistant technique. Recently many sophisticated equipment's and techniques have been described which did not received widespread popularity.
Objectives The Investigator describes and assesses the validity of using Pressure Gauge Manometer to confirm correct detection of lumber epidural space, in an inexpensive way.
Methods Tuohy needle is introduced into intervertebral space at the level of L3-L4 up to the interspinous ligaments ( nearly 2cm mark on the needle).A3-way stopcock is connected to the hub of Tuohy needle with the in-line port of the stopcock attached to an air-filled 10 ml syringe. Using a 75 cm extension tube set and create a 30 mm Hg pressure gradient between manometer and the tip of epidural needle , the needle is advanced slowly using both hands while monitoring the manometer reading and is stopped when the pressure suddenly dropped ( the pressure usually drops by 5-10 mm Hg when the tip of the needle inters the epidural space ).
研究概览
详细说明
• A total of 60 consecutive ASA class 1& II patients of ages between 28-68 years scheduled for elective surgery under lumber epidural anesthesia or under general anesthesia with planned post-operative epidural analgesia were enrolled in this study.
Patients with known coagulation disorder, allergy to local anesthetics, skin lesions at the puncture side, or neuromuscular disease were not included.
Patients are placed in sitting position and American society of anesthesiologists standard monitors attached. After skin preparation, draping, and local anesthetic infiltration, an epidural Tuohy needle is introduced into intervertebral space at the level of L3-L4 up to the interspinous ligaments ( nearly 2cm mark on the needle). Fig 1 A3-way stopcock is connected to the hub of Tuohy needle with the in-line port of the stopcock attached to an air-filled 10 ml syringe. Using a 75 cm extension tube set the side port is connected to the Pressure Gauge Manometer held by the assistant. The stopcock is turned so that the needle is in direct continuity with both syringe and pressure Gage manometer. The syringe is used to create a 30 mm Hg pressure reading on the manometer, the stopcock then is turned into "open" to manometer and Tuohy needle and "close" to syringe.
With this 30 mm Hg pressure gradient between manometer and the tip of epidural needle, the needle is advanced slowly using both hands while monitoring the manometer reading and is stopped when the pressure changes ( the pressure usually drops by 5-10 mm Hg when the tip of the needle inters the epidural space ).
The 3-way is then removed and local anesthetic is injected for single shot epidural block or catheter is introduced in the conventional manner and secured by adhesive tap.
Procedure was performed by anesthetists of different levels of experience (consultant, specialist, resident).
Demographic data and type of surgery is recorded along with time of the technique, number of passes required to enter the epidural space, any false LOR, insertion difficulties, accidental dural puncture, or any other complication occurred.
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Assiut、埃及、71515
- Assiut University ,Faculty Of Medicine ,Anesthesia Department, Egypt
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- ASA class 1& II patients of ages between 28-68 years scheduled for elective surgery under lumber epidural anesthesia or under general anesthesia with planned post-operative epidural analgesia were enrolled in this study.
Exclusion Criteria:
- Patients with known coagulation disorder, allergy to local anesthetics, skin lesions at the puncture side, or neuromuscular disease were not included
学习计划
研究是如何设计的?
设计细节
- 主要用途:卫生服务研究
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Pressure Gauge Manometer
Tuohy needle is introduced into intervertebral space at the level of L3-L4 up to the interspinous ligaments .
The needle is advanced slowly using both hands while monitoring the manometer reading and is stopped when the pressure suddenly dropped ( the pressure usually drops by 5-10 mm Hg when the tip of the needle inters the epidural space ).
|
Identification of epidural space
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Success of the technique.
大体时间:10 minutes after the technique.
|
For epidural catheter placement success of the technique is defined as the installation of sensory block after the end of surgery.
|
10 minutes after the technique.
|
次要结果测量
结果测量 |
大体时间 |
|---|---|
|
The physician satisfaction with the technique (Definitely not, Not completely, Yes)
大体时间:12hours after the end of the technique
|
12hours after the end of the technique
|
合作者和调查者
调查人员
- 首席研究员:Osama A Ibraheim, MD、Assiut University College of medicine
研究记录日期
研究主要日期
学习开始
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计)
研究记录更新
最后更新发布 (估计)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- 010007
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.