Identification of Epidural Space Description of New Technique
Introduction Several attempts have been made to improve or facilitate epidural space detection beside conventional loss of resistant technique. Recently many sophisticated equipment's and techniques have been described which did not received widespread popularity.
Objectives The Investigator describes and assesses the validity of using Pressure Gauge Manometer to confirm correct detection of lumber epidural space, in an inexpensive way.
Methods Tuohy needle is introduced into intervertebral space at the level of L3-L4 up to the interspinous ligaments ( nearly 2cm mark on the needle).A3-way stopcock is connected to the hub of Tuohy needle with the in-line port of the stopcock attached to an air-filled 10 ml syringe. Using a 75 cm extension tube set and create a 30 mm Hg pressure gradient between manometer and the tip of epidural needle , the needle is advanced slowly using both hands while monitoring the manometer reading and is stopped when the pressure suddenly dropped ( the pressure usually drops by 5-10 mm Hg when the tip of the needle inters the epidural space ).
調査の概要
詳細な説明
• A total of 60 consecutive ASA class 1& II patients of ages between 28-68 years scheduled for elective surgery under lumber epidural anesthesia or under general anesthesia with planned post-operative epidural analgesia were enrolled in this study.
Patients with known coagulation disorder, allergy to local anesthetics, skin lesions at the puncture side, or neuromuscular disease were not included.
Patients are placed in sitting position and American society of anesthesiologists standard monitors attached. After skin preparation, draping, and local anesthetic infiltration, an epidural Tuohy needle is introduced into intervertebral space at the level of L3-L4 up to the interspinous ligaments ( nearly 2cm mark on the needle). Fig 1 A3-way stopcock is connected to the hub of Tuohy needle with the in-line port of the stopcock attached to an air-filled 10 ml syringe. Using a 75 cm extension tube set the side port is connected to the Pressure Gauge Manometer held by the assistant. The stopcock is turned so that the needle is in direct continuity with both syringe and pressure Gage manometer. The syringe is used to create a 30 mm Hg pressure reading on the manometer, the stopcock then is turned into "open" to manometer and Tuohy needle and "close" to syringe.
With this 30 mm Hg pressure gradient between manometer and the tip of epidural needle, the needle is advanced slowly using both hands while monitoring the manometer reading and is stopped when the pressure changes ( the pressure usually drops by 5-10 mm Hg when the tip of the needle inters the epidural space ).
The 3-way is then removed and local anesthetic is injected for single shot epidural block or catheter is introduced in the conventional manner and secured by adhesive tap.
Procedure was performed by anesthetists of different levels of experience (consultant, specialist, resident).
Demographic data and type of surgery is recorded along with time of the technique, number of passes required to enter the epidural space, any false LOR, insertion difficulties, accidental dural puncture, or any other complication occurred.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Assiut、エジプト、71515
- Assiut University ,Faculty Of Medicine ,Anesthesia Department, Egypt
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- ASA class 1& II patients of ages between 28-68 years scheduled for elective surgery under lumber epidural anesthesia or under general anesthesia with planned post-operative epidural analgesia were enrolled in this study.
Exclusion Criteria:
- Patients with known coagulation disorder, allergy to local anesthetics, skin lesions at the puncture side, or neuromuscular disease were not included
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:ヘルスサービス研究
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
---|---|
実験的:Pressure Gauge Manometer
Tuohy needle is introduced into intervertebral space at the level of L3-L4 up to the interspinous ligaments .
The needle is advanced slowly using both hands while monitoring the manometer reading and is stopped when the pressure suddenly dropped ( the pressure usually drops by 5-10 mm Hg when the tip of the needle inters the epidural space ).
|
Identification of epidural space
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
---|---|---|
Success of the technique.
時間枠:10 minutes after the technique.
|
For epidural catheter placement success of the technique is defined as the installation of sensory block after the end of surgery.
|
10 minutes after the technique.
|
二次結果の測定
結果測定 |
時間枠 |
---|---|
The physician satisfaction with the technique (Definitely not, Not completely, Yes)
時間枠:12hours after the end of the technique
|
12hours after the end of the technique
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Osama A Ibraheim, MD、Assiut University College of medicine
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- 010007
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。