Ultrasound-guided Femoral Vein Accessibility, Safety and Time for Atrial Fibrillation Treatment (ULTRA-FAST)
Ultrasound-guided or Anatomical Femoral Venipuncture for Pulmonary Vein Isolation for Atrial Fibrillation Treatment
研究概览
地位
详细说明
The number of pulmonary vein isolation (PVI) therapy for atrial fibrillation (AF) is increasing. Multiple femoral vein cannulation is mandatory for this procedure. There are mainly two methods to cannulate the femoral vein; by anatomical landmark or by under real-time ultrasound-guided. As high anticoagulant level is required for the procedure, there are 0-13% of vascular access complication.
Real-time ultrasound assistance for central venous catheter cannulation has been proven to reduce complications. In the field of AF treatment, multiple femoral vein cannulation is required as many catheter is required for the procedure and larger sheaths are inserted with a high anticoagulant level during the procedure. In this setting, the use of ultrasound use is not well studied.
The current study is to confirm whether real time ultrasound-guided femoral vein cannulation for PVI can prevent complications, reduce puncture time, puncture attempts and accidental artery puncture compared to conventional anatomical approach. Two seethes for each femoral vein is going to be cannulated.
The study design is a multicenter prospective randomized trial to compare the above safety and efficacy by using the ultrasound-guided and anatomical landmark approach. Also time for cannulation, number of puncture attempts, need of X-ray for cannulation will be analyzed in the setting of patient factors including age, body mass index and sex.
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
参与标准
资格标准
适合学习的年龄
- 孩子
- 成人
- 年长者
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Patients undergoing pulmonary vein isolation with radiofrequency catheter ablation for atrial fibrillation treatment.
Exclusion Criteria:
- Patients with prior known vascular access problems or priory included to the current study.
学习计划
研究是如何设计的?
设计细节
- 主要用途:预防
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:单身的
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Real-time ultrasound-guided puncture
Cannulate each femoral veins with two wires with real-time ultrasound-guided method.
|
A 7 megahertz ultrasound linear probe will be used.
|
|
其他:Anatomical landmark guided puncture
Cannulate each femoral veins with two wires with the anatomical landmark guided method.
|
Anatomical landmark puncture
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Major complications
大体时间:After the puncture up to 12 weeks
|
Total patient number of vascular complications requiring surgical treatment, retroperitoneal hematoma requiring blood transfusion or hemoglobin drop of 3 >g/dl, strong pain at the groin, prolonging hospital stay and requiring hospital admission after discharge.
|
After the puncture up to 12 weeks
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Unsuccessful femoral vein cannulation
大体时间:Immediately after the puncture
|
Number of patients with unsuccessful femoral vein cannulation defined as crossing over to the other randomized method or change of operator to cannulate all wires.
|
Immediately after the puncture
|
|
Number of puncture attempts
大体时间:Immediately after the puncture
|
Number of puncture attempts to cannulate all wires.
|
Immediately after the puncture
|
|
Total puncture time
大体时间:Immediately after the puncture
|
Time from giving anesthesia to the groin till confirming all wires in the infra vena cava with the X-ray.
|
Immediately after the puncture
|
|
Number of artery mis-punctures
大体时间:Immediately after the puncture
|
Number of artery mis-punctures attempts to cannulate all wires.
|
Immediately after the puncture
|
|
Use of X-ray for successful wire cannulation
大体时间:Immediately after the puncture
|
If there is a need of X-ray to cannulate the wire into the infra vena cava.
|
Immediately after the puncture
|
合作者和调查者
调查人员
- 研究主任:Joseph Kautzner, MD, PhD、Institute for Clinical and Experimental Medicine
出版物和有用的链接
有用的网址
研究记录日期
研究主要日期
学习开始
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.