此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

User Performance Evaluation of Contour® Next One, Accu-Chek® Aviva Connect, FreeStyle Freedom Lite, OneTouch® Verio and GlucoMen® Areo Blood Glucose Monitoring Systems Following ISO 15197:2013

The user performance evaluation shows whether people with diabetes are able to obtain accurate measurement results with a blood glucose monitoring system. In this study, user performance evaluation will be performed for Contour® Next One (Ascensia Diabetes Care GmbH), Accu-Chek® Aviva Connect (Roche Diabetes Care GmbH), FreeStyle Freedom Lite (Abbott Diabetes Care Inc.), OneTouch® Verio (LifeScan Europe) and GlucoMen® areo A. Menarini Diagnostics S.r.l. (based on ISO 15197:2013; EN ISO 15197:2015, clause 8.

For each BGMS, measurement procedures for user performance evaluation will be performed with 1 test meter and 1 reagent system lot by the study subjects.

The same meter and an additional test meter will be used for double measurements performed by study personnel (with the same reagent system lot used by subjects).

研究概览

研究类型

介入性

注册 (实际的)

189

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Baden-Württemberg
      • Ulm、Baden-Württemberg、德国、89081
        • Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Male or female, with type 1 diabetes, type 2 diabetes or subjects without diabetes
  • Signed informed consent form
  • Minimum age of 18 years
  • Subjects are legally competent and capable to understand character, meaning and consequences of the study.
  • If blood glucose values < 80 mg/dl or > 300 mg/dl shall be measured after short term alteration in insulin therapy:
  • Male or female with type 1 diabetes and intensified insulin therapy or insulin pump therapy.
  • Signature of subjects to document consent with these procedures on informed consent form.

Exclusion Criteria:

  • Pregnancy or lactation period
  • Severe acute disease (at the study physician's discretion)
  • Severe chronic disease with potential risk during the test procedures (at the study physician's discretion)
  • Current constitution that compromises the subject's capability to participate in the study (at the study physician's discretion)
  • Being unable to give informed consent
  • < 18 years
  • Legally incompetent
  • Being committed to an institution (e.g. psychiatric clinic)
  • Language barriers potentially compromising an adequate compliance with study procedures
  • Dependent on investigator or sponsor
  • If blood glucose values < 80 mg/dl shall be measured after short term alteration in insulin therapy, subjects with type 1 diabetes, suffering from:
  • Coronary heart disease
  • Condition after myocardial infarction
  • Condition after cerebral events
  • Peripheral arterial occlusive disease
  • Hypoglycemia unawareness

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

武器和干预

参与者组/臂
干预/治疗
实验性的:Blood glucose measurement
Every study subject shall test three out of the five devices. The testing order of the BGMS will be changed on each subject to minimize any order effects on measurement results.

This is a user performance study, that is intended to show whether people with diabetes are able to obtain accurate measurement results with a blood glucose monitoring system (BGMS).

The subjects' measurement technique (e.g. applying blood onto the system reagent, reading the result) will be observed and documented by study personnel.

Immediately after the measurement by the subject, the study personnel will perform a measurement with the same test meter.

Measurement results obtained by the subjects with the BGMS will be compared to measurement results obtained with the comparison method.

Sample collection for the comparison measurement will be performed by study personnel within 5 min after the subject's measurement with the test meter.

The samples will be collected from the subjects' skin puncture (if possible), an additional skin puncture (if required) will be documented.

An additional skin puncture will be performed by study personnel with single-use lancing devices.

其他名称:
  • Contour® Next One, Accu-Chek® Aviva Connect, FreeStyle Freedom Lite, OneTouch® Verio, GlucoMen® areo

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Acceptance criteria defined by ISO 15197:2013 (E) will be applied
大体时间:For each subject, the experimental phase has an expected duration of up to 3 hours
95 % of the individual glucose measured values shall fall within ± 15 mg/dl (0.83 mmol/l) of the measured values of the comparison measurement procedure at glucose concentrations < 100 mg/dl (5.55 mmol/l) and within ± 15 % at glucose concentrations ≥ 100 mg/dl (5.55 mmol/l).
For each subject, the experimental phase has an expected duration of up to 3 hours

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2017年1月1日

初级完成 (实际的)

2017年3月1日

研究完成 (实际的)

2017年3月1日

研究注册日期

首次提交

2017年1月16日

首先提交符合 QC 标准的

2017年1月26日

首次发布 (估计)

2017年1月27日

研究记录更新

最后更新发布 (实际的)

2017年9月12日

上次提交的符合 QC 标准的更新

2017年9月11日

最后验证

2017年9月1日

更多信息

与本研究相关的术语

其他研究编号

  • IDT-1608-AL

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.