- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT03033849
User Performance Evaluation of Contour® Next One, Accu-Chek® Aviva Connect, FreeStyle Freedom Lite, OneTouch® Verio and GlucoMen® Areo Blood Glucose Monitoring Systems Following ISO 15197:2013
The user performance evaluation shows whether people with diabetes are able to obtain accurate measurement results with a blood glucose monitoring system. In this study, user performance evaluation will be performed for Contour® Next One (Ascensia Diabetes Care GmbH), Accu-Chek® Aviva Connect (Roche Diabetes Care GmbH), FreeStyle Freedom Lite (Abbott Diabetes Care Inc.), OneTouch® Verio (LifeScan Europe) and GlucoMen® areo A. Menarini Diagnostics S.r.l. (based on ISO 15197:2013; EN ISO 15197:2015, clause 8.
For each BGMS, measurement procedures for user performance evaluation will be performed with 1 test meter and 1 reagent system lot by the study subjects.
The same meter and an additional test meter will be used for double measurements performed by study personnel (with the same reagent system lot used by subjects).
연구 개요
상태
정황
개입 / 치료
- 장치: Blood glucose monitoring system for self-testing Contour® Next One
- 장치: Blood glucose monitoring system for self-testing Accu-Chek® Aviva Connect
- 장치: Blood glucose monitoring system for self-testing FreeStyle Freedom Lite
- 장치: Blood glucose monitoring system for self-testing OneTouch® Verio
- 장치: Blood glucose monitoring system for self-testing GlucoMen® areo
연구 유형
등록 (실제)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
Baden-Württemberg
-
Ulm, Baden-Württemberg, 독일, 89081
- Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- Male or female, with type 1 diabetes, type 2 diabetes or subjects without diabetes
- Signed informed consent form
- Minimum age of 18 years
- Subjects are legally competent and capable to understand character, meaning and consequences of the study.
- If blood glucose values < 80 mg/dl or > 300 mg/dl shall be measured after short term alteration in insulin therapy:
- Male or female with type 1 diabetes and intensified insulin therapy or insulin pump therapy.
- Signature of subjects to document consent with these procedures on informed consent form.
Exclusion Criteria:
- Pregnancy or lactation period
- Severe acute disease (at the study physician's discretion)
- Severe chronic disease with potential risk during the test procedures (at the study physician's discretion)
- Current constitution that compromises the subject's capability to participate in the study (at the study physician's discretion)
- Being unable to give informed consent
- < 18 years
- Legally incompetent
- Being committed to an institution (e.g. psychiatric clinic)
- Language barriers potentially compromising an adequate compliance with study procedures
- Dependent on investigator or sponsor
- If blood glucose values < 80 mg/dl shall be measured after short term alteration in insulin therapy, subjects with type 1 diabetes, suffering from:
- Coronary heart disease
- Condition after myocardial infarction
- Condition after cerebral events
- Peripheral arterial occlusive disease
- Hypoglycemia unawareness
공부 계획
연구는 어떻게 설계됩니까?
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
---|---|
실험적: Blood glucose measurement
Every study subject shall test three out of the five devices.
The testing order of the BGMS will be changed on each subject to minimize any order effects on measurement results.
|
This is a user performance study, that is intended to show whether people with diabetes are able to obtain accurate measurement results with a blood glucose monitoring system (BGMS). The subjects' measurement technique (e.g. applying blood onto the system reagent, reading the result) will be observed and documented by study personnel. Immediately after the measurement by the subject, the study personnel will perform a measurement with the same test meter. Measurement results obtained by the subjects with the BGMS will be compared to measurement results obtained with the comparison method. Sample collection for the comparison measurement will be performed by study personnel within 5 min after the subject's measurement with the test meter. The samples will be collected from the subjects' skin puncture (if possible), an additional skin puncture (if required) will be documented. An additional skin puncture will be performed by study personnel with single-use lancing devices.
다른 이름들:
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
---|---|---|
Acceptance criteria defined by ISO 15197:2013 (E) will be applied
기간: For each subject, the experimental phase has an expected duration of up to 3 hours
|
95 % of the individual glucose measured values shall fall within ± 15 mg/dl (0.83 mmol/l) of the measured values of the comparison measurement procedure at glucose concentrations < 100 mg/dl (5.55 mmol/l) and within ± 15 % at glucose concentrations ≥ 100 mg/dl (5.55 mmol/l).
|
For each subject, the experimental phase has an expected duration of up to 3 hours
|
공동 작업자 및 조사자
간행물 및 유용한 링크
연구 기록 날짜
연구 주요 날짜
연구 시작
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (추정)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- IDT-1608-AL
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .