Objective Measures in Cochlear Implant
2017年8月22日 更新者:Dina Mohamed、Assiut University
Objective Measures in Cochlear Implant in Children and Its Correlation to Outcome
One of the main factors affecting the ability to maximize the full potential of a cochlear implant is an accurate map.The goal of mapping is to enable cochlear implant recipients to perceive a desired range of acoustic signals.
The process includes programming of the minimum and the maximum stimulation levels that are based on subjective measurements of thresholds and the most comfortable level .
The use of objective measures in the CI process has greatly contributed to the definition of the dynamic field, as they provide specific values that serve as the basis for the start of the mapping process, especially in cases of infants and young children.
Some examples of these measures are electrically evoked stapedius reflex threshold , neural response telemetry , brainstem auditory evoked potential , and P300, among others.
研究概览
地位
未知
条件
详细说明
In adult Cochlear implant users, programming is a relatively straightforward task as psychophysical measurements can be explained, and patients quickly understand the link between the mapping process and the output of their system .
In young children or infants, the mapping process is more complex, especially comfort levels.
Setting the threshold level requires the child to respond to the presence or the absence of a sound.
Although the same techniques are used in setting the comfort level, the child is now required to make a judgment about the sound beyond its simple presence or absence.
Young children often lack the attention span, patience, and cognitive and language skills necessary to perform these tasks with good reliability and repeatability .The use of objective measures in the CI process has greatly contributed to the definition of the dynamic field, as they provide specific values that serve as the basis for the start of the mapping process, especially in cases of infants and young children.
Some examples of these measures are electrically evoked stapedius reflex threshold , neural response telemetry , brainstem auditory evoked potential , and P300, among others.The electrically evoked compound action potentials, which are closely related to the electrically evoked brainstem responses, would also show a similar correlation with the behavioral threshold .
Determining threshold levels requires subjective responses to a series of sophisticated psychophysical percepts.
This is often difficult for cochlear implant patients.
However, the neural response telemetry system renders possible the measurement of the compound action potential threshold .
Electric stapedial reflex threshold measurements are performed using the same software platform and electrical stimulus utilized for fitting the cochlear implant .
Thus, stimulus parameters, including pulse duration and repetition rate, can be identical to those used to obtain behavioral judgments for psychophysical levels .For most implant recipients , even the first introduction of electric stimulation from a cochlear implant evokes activity in the auditory brainstem , which can be measured as clear electric auditory brain stem response waveforms .
Therefore this test can be used in the functional evaluation of the auditory system between the time of initial implant activation and after chronic cochlear implant use.
研究类型
观察性的
注册 (预期的)
30
参与标准
研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。
资格标准
适合学习的年龄
2年 至 6年 (孩子)
接受健康志愿者
不
有资格学习的性别
全部
取样方法
概率样本
研究人群
children with sensorineural hearing loss implanted with Medel multi-channel cochlear implant aged 2-6 years
描述
Inclusion Criteria:
- children implanted with Medel multichannel cochlear implant
Exclusion Criteria:
• Any middle ear problem
- Any technical problems with the cochlear implant device
学习计划
本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
children with cochlear implant
30 subjects whose age ranges from 2-6 years old who are implanted with Medel multichannel cochlear implant male and female will be included and will undergo:-
|
The electrically evoked compound action potentials, which are closely related to the electrically evoked brainstem responses, would also show a similar correlation with the behavioral threshold.
Determining threshold levels requires subjective responses to a series of sophisticated psychophysical percepts.
This is often difficult for cochlear implant patients.
However, the neural response telemetry system renders possible the measurement of the compound action potential threshold .
electric stapedial reflex threshold measurements are performed using the same software platform and electrical stimulus utilized for fitting the cochlear implant .
Thus, stimulus parameters, including pulse duration and repetition rate, can be identical to those used to obtain behavioral judgments for psychophysical levels
For most implant recipients , even the first introduction of electric stimulation from a cochlear implant evokes activity in the auditory brainstem , which can be measured as clear electric auditory brain stem response waveforms .
Therefore the electric auditory brain stem response test can be used in the functional evaluation of the auditory system between the time of initial implant activation and after chronic cochlear implant use
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Arabic language test
大体时间:2 years
|
Speech and language assessment in children with cochlear implant
|
2 years
|
合作者和调查者
在这里您可以找到参与这项研究的人员和组织。
研究记录日期
这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。
研究主要日期
学习开始 (预期的)
2017年12月1日
初级完成 (预期的)
2019年8月31日
研究完成 (预期的)
2019年12月30日
研究注册日期
首次提交
2017年8月20日
首先提交符合 QC 标准的
2017年8月22日
首次发布 (实际的)
2017年8月24日
研究记录更新
最后更新发布 (实际的)
2017年8月24日
上次提交的符合 QC 标准的更新
2017年8月22日
最后验证
2017年8月1日
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.