Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Objective Measures in Cochlear Implant

22 agosto 2017 aggiornato da: Dina Mohamed, Assiut University

Objective Measures in Cochlear Implant in Children and Its Correlation to Outcome

One of the main factors affecting the ability to maximize the full potential of a cochlear implant is an accurate map.The goal of mapping is to enable cochlear implant recipients to perceive a desired range of acoustic signals. The process includes programming of the minimum and the maximum stimulation levels that are based on subjective measurements of thresholds and the most comfortable level . The use of objective measures in the CI process has greatly contributed to the definition of the dynamic field, as they provide specific values that serve as the basis for the start of the mapping process, especially in cases of infants and young children. Some examples of these measures are electrically evoked stapedius reflex threshold , neural response telemetry , brainstem auditory evoked potential , and P300, among others.

Panoramica dello studio

Descrizione dettagliata

In adult Cochlear implant users, programming is a relatively straightforward task as psychophysical measurements can be explained, and patients quickly understand the link between the mapping process and the output of their system . In young children or infants, the mapping process is more complex, especially comfort levels. Setting the threshold level requires the child to respond to the presence or the absence of a sound. Although the same techniques are used in setting the comfort level, the child is now required to make a judgment about the sound beyond its simple presence or absence. Young children often lack the attention span, patience, and cognitive and language skills necessary to perform these tasks with good reliability and repeatability .The use of objective measures in the CI process has greatly contributed to the definition of the dynamic field, as they provide specific values that serve as the basis for the start of the mapping process, especially in cases of infants and young children. Some examples of these measures are electrically evoked stapedius reflex threshold , neural response telemetry , brainstem auditory evoked potential , and P300, among others.The electrically evoked compound action potentials, which are closely related to the electrically evoked brainstem responses, would also show a similar correlation with the behavioral threshold . Determining threshold levels requires subjective responses to a series of sophisticated psychophysical percepts. This is often difficult for cochlear implant patients. However, the neural response telemetry system renders possible the measurement of the compound action potential threshold . Electric stapedial reflex threshold measurements are performed using the same software platform and electrical stimulus utilized for fitting the cochlear implant . Thus, stimulus parameters, including pulse duration and repetition rate, can be identical to those used to obtain behavioral judgments for psychophysical levels .For most implant recipients , even the first introduction of electric stimulation from a cochlear implant evokes activity in the auditory brainstem , which can be measured as clear electric auditory brain stem response waveforms . Therefore this test can be used in the functional evaluation of the auditory system between the time of initial implant activation and after chronic cochlear implant use.

Tipo di studio

Osservativo

Iscrizione (Anticipato)

30

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 2 anni a 6 anni (Bambino)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Metodo di campionamento

Campione di probabilità

Popolazione di studio

children with sensorineural hearing loss implanted with Medel multi-channel cochlear implant aged 2-6 years

Descrizione

Inclusion Criteria:

  • children implanted with Medel multichannel cochlear implant

Exclusion Criteria:

  • • Any middle ear problem

    • Any technical problems with the cochlear implant device

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

Coorti e interventi

Gruppo / Coorte
Intervento / Trattamento
children with cochlear implant

30 subjects whose age ranges from 2-6 years old who are implanted with Medel multichannel cochlear implant male and female will be included and will undergo:-

  • Electric compound action potential
  • Electric stapedial reflex threshold
  • Electric auditory brain stem response
The electrically evoked compound action potentials, which are closely related to the electrically evoked brainstem responses, would also show a similar correlation with the behavioral threshold. Determining threshold levels requires subjective responses to a series of sophisticated psychophysical percepts. This is often difficult for cochlear implant patients. However, the neural response telemetry system renders possible the measurement of the compound action potential threshold .
electric stapedial reflex threshold measurements are performed using the same software platform and electrical stimulus utilized for fitting the cochlear implant . Thus, stimulus parameters, including pulse duration and repetition rate, can be identical to those used to obtain behavioral judgments for psychophysical levels
For most implant recipients , even the first introduction of electric stimulation from a cochlear implant evokes activity in the auditory brainstem , which can be measured as clear electric auditory brain stem response waveforms . Therefore the electric auditory brain stem response test can be used in the functional evaluation of the auditory system between the time of initial implant activation and after chronic cochlear implant use

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Arabic language test
Lasso di tempo: 2 years
Speech and language assessment in children with cochlear implant
2 years

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Anticipato)

1 dicembre 2017

Completamento primario (Anticipato)

31 agosto 2019

Completamento dello studio (Anticipato)

30 dicembre 2019

Date di iscrizione allo studio

Primo inviato

20 agosto 2017

Primo inviato che soddisfa i criteri di controllo qualità

22 agosto 2017

Primo Inserito (Effettivo)

24 agosto 2017

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

24 agosto 2017

Ultimo aggiornamento inviato che soddisfa i criteri QC

22 agosto 2017

Ultimo verificato

1 agosto 2017

Maggiori informazioni

Termini relativi a questo studio

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

prodotto fabbricato ed esportato dagli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi