Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Objective Measures in Cochlear Implant

22. srpna 2017 aktualizováno: Dina Mohamed, Assiut University

Objective Measures in Cochlear Implant in Children and Its Correlation to Outcome

One of the main factors affecting the ability to maximize the full potential of a cochlear implant is an accurate map.The goal of mapping is to enable cochlear implant recipients to perceive a desired range of acoustic signals. The process includes programming of the minimum and the maximum stimulation levels that are based on subjective measurements of thresholds and the most comfortable level . The use of objective measures in the CI process has greatly contributed to the definition of the dynamic field, as they provide specific values that serve as the basis for the start of the mapping process, especially in cases of infants and young children. Some examples of these measures are electrically evoked stapedius reflex threshold , neural response telemetry , brainstem auditory evoked potential , and P300, among others.

Přehled studie

Detailní popis

In adult Cochlear implant users, programming is a relatively straightforward task as psychophysical measurements can be explained, and patients quickly understand the link between the mapping process and the output of their system . In young children or infants, the mapping process is more complex, especially comfort levels. Setting the threshold level requires the child to respond to the presence or the absence of a sound. Although the same techniques are used in setting the comfort level, the child is now required to make a judgment about the sound beyond its simple presence or absence. Young children often lack the attention span, patience, and cognitive and language skills necessary to perform these tasks with good reliability and repeatability .The use of objective measures in the CI process has greatly contributed to the definition of the dynamic field, as they provide specific values that serve as the basis for the start of the mapping process, especially in cases of infants and young children. Some examples of these measures are electrically evoked stapedius reflex threshold , neural response telemetry , brainstem auditory evoked potential , and P300, among others.The electrically evoked compound action potentials, which are closely related to the electrically evoked brainstem responses, would also show a similar correlation with the behavioral threshold . Determining threshold levels requires subjective responses to a series of sophisticated psychophysical percepts. This is often difficult for cochlear implant patients. However, the neural response telemetry system renders possible the measurement of the compound action potential threshold . Electric stapedial reflex threshold measurements are performed using the same software platform and electrical stimulus utilized for fitting the cochlear implant . Thus, stimulus parameters, including pulse duration and repetition rate, can be identical to those used to obtain behavioral judgments for psychophysical levels .For most implant recipients , even the first introduction of electric stimulation from a cochlear implant evokes activity in the auditory brainstem , which can be measured as clear electric auditory brain stem response waveforms . Therefore this test can be used in the functional evaluation of the auditory system between the time of initial implant activation and after chronic cochlear implant use.

Typ studie

Pozorovací

Zápis (Očekávaný)

30

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

2 roky až 6 let (Dítě)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Všechno

Metoda odběru vzorků

Ukázka pravděpodobnosti

Studijní populace

children with sensorineural hearing loss implanted with Medel multi-channel cochlear implant aged 2-6 years

Popis

Inclusion Criteria:

  • children implanted with Medel multichannel cochlear implant

Exclusion Criteria:

  • • Any middle ear problem

    • Any technical problems with the cochlear implant device

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

Kohorty a intervence

Skupina / kohorta
Intervence / Léčba
children with cochlear implant

30 subjects whose age ranges from 2-6 years old who are implanted with Medel multichannel cochlear implant male and female will be included and will undergo:-

  • Electric compound action potential
  • Electric stapedial reflex threshold
  • Electric auditory brain stem response
The electrically evoked compound action potentials, which are closely related to the electrically evoked brainstem responses, would also show a similar correlation with the behavioral threshold. Determining threshold levels requires subjective responses to a series of sophisticated psychophysical percepts. This is often difficult for cochlear implant patients. However, the neural response telemetry system renders possible the measurement of the compound action potential threshold .
electric stapedial reflex threshold measurements are performed using the same software platform and electrical stimulus utilized for fitting the cochlear implant . Thus, stimulus parameters, including pulse duration and repetition rate, can be identical to those used to obtain behavioral judgments for psychophysical levels
For most implant recipients , even the first introduction of electric stimulation from a cochlear implant evokes activity in the auditory brainstem , which can be measured as clear electric auditory brain stem response waveforms . Therefore the electric auditory brain stem response test can be used in the functional evaluation of the auditory system between the time of initial implant activation and after chronic cochlear implant use

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Arabic language test
Časové okno: 2 years
Speech and language assessment in children with cochlear implant
2 years

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Očekávaný)

1. prosince 2017

Primární dokončení (Očekávaný)

31. srpna 2019

Dokončení studie (Očekávaný)

30. prosince 2019

Termíny zápisu do studia

První předloženo

20. srpna 2017

První předloženo, které splnilo kritéria kontroly kvality

22. srpna 2017

První zveřejněno (Aktuální)

24. srpna 2017

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

24. srpna 2017

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

22. srpna 2017

Naposledy ověřeno

1. srpna 2017

Více informací

Termíny související s touto studií

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

produkt vyrobený a vyvážený z USA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Klinické studie na Senzorineurální ztráta sluchu

Klinické studie na Electric compound action potential

3
Předplatit