Tissue Doppler Echocardiographic Assessment of Cardiac Function in Neonatal Sepsis
Tissue Doppler Echocardiographic Assessment of Cardiac Function in Neonatal Sepsis and Correlation With Cardiac Troponin and Sepsis Biomarkers
- To assess myocardial function in neonates with sepsis using tissue doppler echocardiography.
- To assess sepsis induced cardiac dysfunction.
- To measure serum levels of sepsis markers (CBC,CRP,Blood culture) and cardiac troponin in neonatal sepsis.
- To analyze the correlation between echocardiographic parameters and serum biomarkers.
- To determine whether these echocardiographic techniques can serve as early predictors of cardiac involvement in neonatal sepsis.
研究概览
详细说明
Sepsis and septic shock are recognized as one of the most frequent causes of mortal complications in neonatal intensive care units worldwide. It has been observed that early-onset sepsis has become a serious and common issue among neonates, especially preterm infants (1) Cardiac dysfunction is a well-recognized complication of severe sepsis and septic shock and is a major contributor to morbidity and mortality in patients with sepsis [2].
The increasing use of echocardiographic techniques in neonatal intensive care units (NICU) has resulted in significant progress in the treatment of severely ill neonates in the last ten years, enabling more accurate and rapid assessment of the hemodynamic status of these fragile patients, in addition to introducing the possibility of individually tailored therapy for each patient. There is a current worldwide trend of intensive care pediatricians and neonatologists being trained to apply echocardiographic techniques, enabling the use of data obtained in everyday practice for clinical decision making [3].
Echocardiography emerges as a cornerstone in the non-invasive assessment of cardiac structure and function. Its capacity to be employed at the bedside offers immediate, real-time hemodynamic evaluation, making it an indispensable tool in neonatal intensive care. Through echocardiographic imaging, clinicians can delineate the cardiovascular profile of each neonate and tailor therapeutic approaches to address the specific underlying physio pathological abnormalities (4) Doppler echocardiography serves as another typical approach to assess cardiac structure and function. Sepsis-related CVD presents a <50% decrease in cardiac output or left ventricular ejection fraction (LVEF) (5) Tissue Doppler imaging is more sensitive in assessing diastolic function and is less dependent on preload and afterload than conventional Doppler methods [6].
研究类型
注册 (估计的)
联系人和位置
学习联系方式
- 姓名:Gehan Mohamed Gehan Mohamed Galal Shehata
- 电话号码:+201011087742
- 邮箱:gehangalal@aun.edu.eg
研究联系人备份
- 姓名:Abd Ellatif A.Moiz Abd Ellatif M.Abdel Moiz
- 电话号码:01005208016
- 邮箱:a.m.abdelmoez@aun.edu.eg
学习地点
-
-
-
Asyut、埃及
- Faculty of Medicine
-
接触:
- Gehan Galal
- 电话号码:01011087742
- 邮箱:gehangalal2030@gmail.com
-
-
参与标准
资格标准
适合学习的年龄
- 孩子
接受健康志愿者
取样方法
研究人群
neonate with sepsis (both preterm and term neonate confirmed to have neonatal sepsis by positive sepsis markers (CBC, CRP, Blood culture))
- control group include healthy group admitted for weight gain or jaundice) Babies on ventilators and non-invasive ventilation, septic shock are included in the study
描述
Inclusion Criteria:
This study includes 2 groups
- sepsis group include neonate e sepsis (both preterm and term neonate confirmed to have neonatal sepsis by positive sepsis markers (CBC, CRP, Blood culture))
control group include healthy group admitted for weight gain or jaundice) Babies on ventilators and non-invasive ventilation, septic shock are included in the study
-
Exclusion Criteria:
Infants with other comorbidities as congenital malformations, genetic syndromes, congenital heart diseases, infants of diabetic mothers, infants with hypoxic ischemic encephalopathy (HIE) or critical CHDs will be excluded from the study.
-
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
sepsis group include neonate with sepsis (both preterm and term neonate)
confirmed to have neonatal sepsis by positive sepsis markers (CBC, CRP, Blood culture))
|
D) Echocardiographic examination: will be done according to the recommendation of the American Society of Echocardiography Integrated M-mode, two-dimensional (2-D) mode and pulsed and continuous wave Doppler will be used to estimate left ventricle (LV) internal dimensions including LV end diastolic dimension, LV ventricle end systolic dimension, ventricular septal thickness, posterior wall thickness, fractional shortening, mitral and tricuspid inflow velocities, and systolic pulmonary artery pressure.
From the apical four-chamber planes, using pulsed wave tissue Doppler, the myocardial velocity curves of septal mitral valve annulus, lateral mitral valve annulus, and lateral tricuspid valve annulus will be recorded.
The systolic wave (S) reflects the systolic function of either right or left ventricle.
The early/atrial (E'/A') ratio of tricuspid and mitral valve annulus reflects the diastolic function of the right and left ventricle, respectively.
|
|
- control group include healthy group admitted for weight gain or jaundice)
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
assess myocardial function in neonates with sepsis using tissue doppler echocardiography.
大体时间:1 year
|
To analyze the correlation between echocardiographic parameters and serum biomarkers.
|
1 year
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
To measure serum levels of sepsis markers (CBC,CRP,Blood culture) and cardiac troponin in neonatal sepsis.
大体时间:1 year
|
determine whether these echocardiographic techniques can serve as early predictors of cardiac involvement in neonatal sepsis.
|