Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Tissue Doppler Echocardiographic Assessment of Cardiac Function in Neonatal Sepsis

1 mai 2026 mis à jour par: Gehan Mohamed Galal, Assiut University

Tissue Doppler Echocardiographic Assessment of Cardiac Function in Neonatal Sepsis and Correlation With Cardiac Troponin and Sepsis Biomarkers

  1. To assess myocardial function in neonates with sepsis using tissue doppler echocardiography.
  2. To assess sepsis induced cardiac dysfunction.
  3. To measure serum levels of sepsis markers (CBC,CRP,Blood culture) and cardiac troponin in neonatal sepsis.
  4. To analyze the correlation between echocardiographic parameters and serum biomarkers.
  5. To determine whether these echocardiographic techniques can serve as early predictors of cardiac involvement in neonatal sepsis.

Aperçu de l'étude

Statut

Pas encore de recrutement

Les conditions

Description détaillée

Sepsis and septic shock are recognized as one of the most frequent causes of mortal complications in neonatal intensive care units worldwide. It has been observed that early-onset sepsis has become a serious and common issue among neonates, especially preterm infants (1) Cardiac dysfunction is a well-recognized complication of severe sepsis and septic shock and is a major contributor to morbidity and mortality in patients with sepsis [2].

The increasing use of echocardiographic techniques in neonatal intensive care units (NICU) has resulted in significant progress in the treatment of severely ill neonates in the last ten years, enabling more accurate and rapid assessment of the hemodynamic status of these fragile patients, in addition to introducing the possibility of individually tailored therapy for each patient. There is a current worldwide trend of intensive care pediatricians and neonatologists being trained to apply echocardiographic techniques, enabling the use of data obtained in everyday practice for clinical decision making [3].

Echocardiography emerges as a cornerstone in the non-invasive assessment of cardiac structure and function. Its capacity to be employed at the bedside offers immediate, real-time hemodynamic evaluation, making it an indispensable tool in neonatal intensive care. Through echocardiographic imaging, clinicians can delineate the cardiovascular profile of each neonate and tailor therapeutic approaches to address the specific underlying physio pathological abnormalities (4) Doppler echocardiography serves as another typical approach to assess cardiac structure and function. Sepsis-related CVD presents a <50% decrease in cardiac output or left ventricular ejection fraction (LVEF) (5) Tissue Doppler imaging is more sensitive in assessing diastolic function and is less dependent on preload and afterload than conventional Doppler methods [6].

Type d'étude

Observationnel

Inscription (Estimé)

80

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

  • Nom: Gehan Mohamed Gehan Mohamed Galal Shehata
  • Numéro de téléphone: +201011087742
  • E-mail: gehangalal@aun.edu.eg

Sauvegarde des contacts de l'étude

Lieux d'étude

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Enfant

Accepte les volontaires sains

Oui

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

neonate with sepsis (both preterm and term neonate confirmed to have neonatal sepsis by positive sepsis markers (CBC, CRP, Blood culture))

- control group include healthy group admitted for weight gain or jaundice) Babies on ventilators and non-invasive ventilation, septic shock are included in the study

La description

Inclusion Criteria:

This study includes 2 groups

  1. sepsis group include neonate e sepsis (both preterm and term neonate confirmed to have neonatal sepsis by positive sepsis markers (CBC, CRP, Blood culture))
  2. control group include healthy group admitted for weight gain or jaundice) Babies on ventilators and non-invasive ventilation, septic shock are included in the study

    -

    Exclusion Criteria:

    Infants with other comorbidities as congenital malformations, genetic syndromes, congenital heart diseases, infants of diabetic mothers, infants with hypoxic ischemic encephalopathy (HIE) or critical CHDs will be excluded from the study.

    -

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
sepsis group include neonate with sepsis (both preterm and term neonate)
confirmed to have neonatal sepsis by positive sepsis markers (CBC, CRP, Blood culture))
D) Echocardiographic examination: will be done according to the recommendation of the American Society of Echocardiography Integrated M-mode, two-dimensional (2-D) mode and pulsed and continuous wave Doppler will be used to estimate left ventricle (LV) internal dimensions including LV end diastolic dimension, LV ventricle end systolic dimension, ventricular septal thickness, posterior wall thickness, fractional shortening, mitral and tricuspid inflow velocities, and systolic pulmonary artery pressure. From the apical four-chamber planes, using pulsed wave tissue Doppler, the myocardial velocity curves of septal mitral valve annulus, lateral mitral valve annulus, and lateral tricuspid valve annulus will be recorded. The systolic wave (S) reflects the systolic function of either right or left ventricle. The early/atrial (E'/A') ratio of tricuspid and mitral valve annulus reflects the diastolic function of the right and left ventricle, respectively.
- control group include healthy group admitted for weight gain or jaundice)

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
assess myocardial function in neonates with sepsis using tissue doppler echocardiography.
Délai: 1 year
To analyze the correlation between echocardiographic parameters and serum biomarkers.
1 year

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
To measure serum levels of sepsis markers (CBC,CRP,Blood culture) and cardiac troponin in neonatal sepsis.
Délai: 1 year
determine whether these echocardiographic techniques can serve as early predictors of cardiac involvement in neonatal sepsis.
1 year

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Liens utiles

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

1 mai 2026

Achèvement primaire (Estimé)

1 mai 2028

Achèvement de l'étude (Estimé)

1 mai 2029

Dates d'inscription aux études

Première soumission

1 mai 2026

Première soumission répondant aux critères de contrôle qualité

1 mai 2026

Première publication (Réel)

7 mai 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

7 mai 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

1 mai 2026

Dernière vérification

1 mai 2026

Plus d'information

Termes liés à cette étude

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner