Comparison of Laboratory-Fabricated and 3D-Printed Rapid Maxillary Expansion Appliances

2026年9月3日 更新者:Baskent University

Comparison of the Skeletal and Dentoalveolar Effects and Patient Comfort of Conventional and 3D-Printed Maxillary Expansion Appliances in Mixed Dentition Patients

The goal of this clinical trial is to determine whether two types of rapid maxillary expansion (RME) appliances produce different outcomes in children. RME is a treatment utilized to expand a narrow upper jaw. This study will include children aged 8 to 10 years who need upper jaw expansion during the mixed dentition period (when they have both temporary and permanent teeth).

The main questions this study aims to answer are:

  • Do 3D-printed expansion appliances produce different skeletal and dental changes compared to conventionally fabricated appliances?
  • Do children feel more comfortable with one type of appliance?
  • Is there a difference in pain levels or oral hygiene between the two groups?

Researchers aimed to compare a conventionally fabricated expansion appliance manufactured in a dental laboratory with a 3D-printed expansion appliance produced digitally to determine whether the method of production affects treatment outcomes and patient comfort.

Participants:

  • Being treated with one of the two expansion appliances (assigned randomly)
  • Follow a standard activation protocol at home with parental guidance
  • Attend regular clinic visits during expansion and retention phases
  • Have dental photographs, X-rays, and digital scans taken before and after treatment
  • Complete an oral health-related quality of life questionnaire
  • Rate their pain using a pain scale
  • Have their oral hygiene measured

研究概览

详细说明

Treatment effectiveness, amount of expansion, and patient comfort will be evaluated between the two groups. Additionally, the impact of digital appliance production on treatment outcomes and patient satisfaction will be investigated.

This prospective, parallel-group, randomized clinical trial aims to compare the skeletal, dentoalveolar, and patient-reported effects of conventionally fabricated and three-dimensional (3D) printed rapid maxillary expansion (RME) appliances in children with transverse maxillary deficiency during the mixed dentition period.

Participants aged 8-10 years who meet the predefined inclusion criteria and require rapid maxillary expansion as part of their orthodontic treatment will be enrolled.

The results are expected to contribute evidence-based guidance for orthodontists when selecting appliance fabrication methods, balancing biological effectiveness with patient comfort and quality-of-life considerations.

Findings from this study may also support future digital workflow integration strategies in pediatric orthodontic treatment planning.

研究类型

介入性

注册 (实际的)

48

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Ankara、土耳其(türkiye)、06490
        • Baskent University Faculty of Dentistry, Department of Orthodontics

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 孩子

接受健康志愿者

不

描述

Inclusion Criteria:

  • Children aged between 7 and 11 years
  • In the mixed dentition period
  • Fully erupted permanent first molars
  • Presence of primary canines and primary second molars suitable for use as anchorage units for at least 6 months
  • Angle Class I or Class II molar relationship
  • Presence of posterior crossbite and/or moderate maxillary transverse deficiency or moderate crowding
  • Prepubertal growth stage corresponding to Cervical Vertebral Maturation Stage 1 (CVM1) or Stage 2 (CVM2)
  • Receiving orthodontic treatment at the Başkent University Department of Orthodontics
  • Parents or legal guardians willing to provide written informed consent

Exclusion Criteria:

  • Previous orthodontic treatment
  • Periodontal disease
  • Enamel hypocalcification or significant calcium deficiency
  • Root resorption
  • Signs or symptoms of temporomandibular joint dysfunction
  • Angle Class III molar relationship
  • Craniofacial syndromes
  • Cleft lip and/or palate
  • Known allergy to acrylic materials or metal alloys
  • Inability to maintain adequate oral hygiene during treatment
  • Lack of cooperation during treatment
  • Repeated appliance breakage or dislodgement (three or more times)

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
实验性的:Laboratory-fabricated rapid maxillary expansion appliance
Participants are treated with a laboratory-fabricated rapid maxillary expansion (RME) appliance produced on a dental cast obtained from conventional impressions. The arms of the palatal expansion screw are adapted and soldered to orthodontic molar bands on the cast model. Following adaptation, acrylic resin is added in the palatal region to increase the force distribution area. The appliance is cemented to the teeth using glass ionomer cement. Activation and retention protocols are standardized across both groups.
A rapid maxillary expansion (RME) appliance fabricated on a dental cast obtained from conventional impressions. The expansion screw arms are adapted and soldered to orthodontic molar bands on the cast.
其他名称:
  • Conventional rapid maxillary expansion appliance
  • Modified haas-type RME appliance used in mixed dentition
实验性的:3D-printed rapid maxillary expansion appliance
Participants are treated with a rapid maxillary expansion (RME) appliance fabricated using digital intraoral scans. Dental models are generated from intraoral scan data, and the appliance framework, including the arms and tooth-supporting components, is manufactured as a single-piece structure using three-dimensional (3D) metal printing technology with sintered cobalt-chromium alloy. After fabrication, acrylic resin is added to the palatal region to increase the force distribution area. The appliance is cemented to the teeth using glass ionomer cement. Activation and retention protocols are standardized across both groups.
A rapid maxillary expansion (RME) appliance fabricated using digital intraoral scan data. Dental models are generated from intraoral scans, and the appliance framework is manufactured as a single-piece structure using three-dimensional (3D) metal printing with sintered cobalt-chromium alloy.
其他名称:
  • Digitally fabricated modified haas-type RME appliance used in mixed dentition

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Change in maxillary transverse skeletal width and intermolar width from T0 to T2
大体时间:-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
The primary outcome is the difference in transverse skeletal maxillary width and maxillary intermolar width between baseline (T0) and the end of the 3-month retention period (T2). Skeletal measurements will be obtained from standardized posteroanterior cephalometric radiographs, and dental measurements will be obtained from digital model analysis.
-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)

次要结果测量

结果测量
措施说明
大体时间
Wong-Baker FACES Pain Rating Scale score
大体时间:-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
Pain perception will be assessed using the Wong-Baker FACES Pain Rating Scale at predefined time points during treatment. Scores will be recorded and compared between groups.
-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
Child Perceptions Questionnaire (CPQ 8-10)
大体时间:-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
Oral health-related quality of life will be assessed using the validated Child Perceptions Questionnaire (CPQ 8-10). Total and domain scores (oral symptoms, functional limitations, emotional well-being, social well-being) will be recorded and compared between groups.
-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
Modified Silness-Löe Plaque Index score
大体时间:-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
Oral hygiene status will be evaluated using the Modified Silness-Löe Plaque Index at predefined time points during treatment to monitor plaque accumulation and compare oral hygiene changes between groups.
-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)

其他结果措施

结果测量
措施说明
大体时间
3D digital model superimposition-based surface deviation
大体时间:-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
Digital models obtained at T0 and T2 will be superimposed using the medial two-thirds of the third palatal rugae and the posterior palatal vault as stable reference areas.
-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 学习椅:Habibe Sinem Ince Bingol, DDS, Orthodontist、Hacettepe Unversity, Faculty of Dentistry, Department of Orthodontics
  • 首席研究员:Sinem Tekdemir, DDS、Baskent University, Faculty of Dentistry, Department of Orthodontics

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2025年8月7日

初级完成 (实际的)

2026年7月31日

研究完成 (估计的)

2026年12月1日

研究注册日期

首次提交

2026年2月23日

首先提交符合 QC 标准的

2026年5月14日

首次发布 (实际的)

2026年5月20日

研究记录更新

最后更新发布 (实际的)

2026年9月4日

上次提交的符合 QC 标准的更新

2026年9月3日

最后验证

2026年9月1日

更多信息

与本研究相关的术语

其他研究编号

  • D-KA24/41
  • 2025-066 (其他标识符:Turkish Medicines and Medical Devices Agency Clinical Trial Authorization Number)
  • 25/31 (其他标识符:Baskent University Institutional Ethics Committee Approval Number)

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

IPD 计划说明

Individual participant data (IPD) will not be shared due to institutional policies, ethical committee regulations, and patient confidentiality considerations.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.