- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07599202
Comparison of Laboratory-Fabricated and 3D-Printed Rapid Maxillary Expansion Appliances
Comparison of the Skeletal and Dentoalveolar Effects and Patient Comfort of Conventional and 3D-Printed Maxillary Expansion Appliances in Mixed Dentition Patients
The goal of this clinical trial is to determine whether two types of rapid maxillary expansion (RME) appliances produce different outcomes in children. RME is a treatment utilized to expand a narrow upper jaw. This study will include children aged 8 to 10 years who need upper jaw expansion during the mixed dentition period (when they have both temporary and permanent teeth).
The main questions this study aims to answer are:
- Do 3D-printed expansion appliances produce different skeletal and dental changes compared to conventionally fabricated appliances?
- Do children feel more comfortable with one type of appliance?
- Is there a difference in pain levels or oral hygiene between the two groups?
Researchers aimed to compare a conventionally fabricated expansion appliance manufactured in a dental laboratory with a 3D-printed expansion appliance produced digitally to determine whether the method of production affects treatment outcomes and patient comfort.
Participants:
- Being treated with one of the two expansion appliances (assigned randomly)
- Follow a standard activation protocol at home with parental guidance
- Attend regular clinic visits during expansion and retention phases
- Have dental photographs, X-rays, and digital scans taken before and after treatment
- Complete an oral health-related quality of life questionnaire
- Rate their pain using a pain scale
- Have their oral hygiene measured
Studie Overzicht
Toestand
Conditie
Gedetailleerde beschrijving
Treatment effectiveness, amount of expansion, and patient comfort will be evaluated between the two groups. Additionally, the impact of digital appliance production on treatment outcomes and patient satisfaction will be investigated.
This prospective, parallel-group, randomized clinical trial aims to compare the skeletal, dentoalveolar, and patient-reported effects of conventionally fabricated and three-dimensional (3D) printed rapid maxillary expansion (RME) appliances in children with transverse maxillary deficiency during the mixed dentition period.
Participants aged 8-10 years who meet the predefined inclusion criteria and require rapid maxillary expansion as part of their orthodontic treatment will be enrolled.
The results are expected to contribute evidence-based guidance for orthodontists when selecting appliance fabrication methods, balancing biological effectiveness with patient comfort and quality-of-life considerations.
Findings from this study may also support future digital workflow integration strategies in pediatric orthodontic treatment planning.
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Ankara, Turkije (Türkiye), 06490
- Baskent University Faculty of Dentistry, Department of Orthodontics
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Kind
Accepteert gezonde vrijwilligers
Beschrijving
Inclusion Criteria:
- Children aged between 7 and 11 years
- In the mixed dentition period
- Fully erupted permanent first molars
- Presence of primary canines and primary second molars suitable for use as anchorage units for at least 6 months
- Angle Class I or Class II molar relationship
- Presence of posterior crossbite and/or moderate maxillary transverse deficiency or moderate crowding
- Prepubertal growth stage corresponding to Cervical Vertebral Maturation Stage 1 (CVM1) or Stage 2 (CVM2)
- Receiving orthodontic treatment at the Başkent University Department of Orthodontics
- Parents or legal guardians willing to provide written informed consent
Exclusion Criteria:
- Previous orthodontic treatment
- Periodontal disease
- Enamel hypocalcification or significant calcium deficiency
- Root resorption
- Signs or symptoms of temporomandibular joint dysfunction
- Angle Class III molar relationship
- Craniofacial syndromes
- Cleft lip and/or palate
- Known allergy to acrylic materials or metal alloys
- Inability to maintain adequate oral hygiene during treatment
- Lack of cooperation during treatment
- Repeated appliance breakage or dislodgement (three or more times)
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Enkel
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Laboratory-fabricated rapid maxillary expansion appliance
Participants are treated with a laboratory-fabricated rapid maxillary expansion (RME) appliance produced on a dental cast obtained from conventional impressions.
The arms of the palatal expansion screw are adapted and soldered to orthodontic molar bands on the cast model.
Following adaptation, acrylic resin is added in the palatal region to increase the force distribution area.
The appliance is cemented to the teeth using glass ionomer cement.
Activation and retention protocols are standardized across both groups.
|
A rapid maxillary expansion (RME) appliance fabricated on a dental cast obtained from conventional impressions.
The expansion screw arms are adapted and soldered to orthodontic molar bands on the cast.
Andere namen:
|
|
Experimenteel: 3D-printed rapid maxillary expansion appliance
Participants are treated with a rapid maxillary expansion (RME) appliance fabricated using digital intraoral scans.
Dental models are generated from intraoral scan data, and the appliance framework, including the arms and tooth-supporting components, is manufactured as a single-piece structure using three-dimensional (3D) metal printing technology with sintered cobalt-chromium alloy.
After fabrication, acrylic resin is added to the palatal region to increase the force distribution area.
The appliance is cemented to the teeth using glass ionomer cement.
Activation and retention protocols are standardized across both groups.
|
A rapid maxillary expansion (RME) appliance fabricated using digital intraoral scan data.
Dental models are generated from intraoral scans, and the appliance framework is manufactured as a single-piece structure using three-dimensional (3D) metal printing with sintered cobalt-chromium alloy.
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Change in maxillary transverse skeletal width and intermolar width from T0 to T2
Tijdsspanne: -Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
|
The primary outcome is the difference in transverse skeletal maxillary width and maxillary intermolar width between baseline (T0) and the end of the 3-month retention period (T2).
Skeletal measurements will be obtained from standardized posteroanterior cephalometric radiographs, and dental measurements will be obtained from digital model analysis.
|
-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Wong-Baker FACES Pain Rating Scale score
Tijdsspanne: -Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
|
Pain perception will be assessed using the Wong-Baker FACES Pain Rating Scale at predefined time points during treatment.
Scores will be recorded and compared between groups.
|
-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
|
|
Child Perceptions Questionnaire (CPQ 8-10)
Tijdsspanne: -Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
|
Oral health-related quality of life will be assessed using the validated Child Perceptions Questionnaire (CPQ 8-10).
Total and domain scores (oral symptoms, functional limitations, emotional well-being, social well-being) will be recorded and compared between groups.
|
-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
|
|
Modified Silness-Löe Plaque Index score
Tijdsspanne: -Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
|
Oral hygiene status will be evaluated using the Modified Silness-Löe Plaque Index at predefined time points during treatment to monitor plaque accumulation and compare oral hygiene changes between groups.
|
-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
|
Andere uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
3D digital model superimposition-based surface deviation
Tijdsspanne: -Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
|
Digital models obtained at T0 and T2 will be superimposed using the medial two-thirds of the third palatal rugae and the posterior palatal vault as stable reference areas.
|
-Preoperative (T0) -After appliance cementation (within 2 weeks) -1 week after the cementation -End of active expansion (approximately 6-8 weeks after cementation) (T1) -End of the 3 months retention period after T1, prior to appliance removal (T2)
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Studie stoel: Habibe Sinem Ince Bingol, DDS, Orthodontist, Hacettepe Unversity, Faculty of Dentistry, Department of Orthodontics
- Hoofdonderzoeker: Sinem Tekdemir, DDS, Baskent University, Faculty of Dentistry, Department of Orthodontics
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Andere studie-ID-nummers
- D-KA24/41
- 2025-066 (Andere identificatie: Turkish Medicines and Medical Devices Agency Clinical Trial Authorization Number)
- 25/31 (Andere identificatie: Baskent University Institutional Ethics Committee Approval Number)
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Beschrijving IPD-plan
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .